Review Type |
Outcome |
Est. Completion Date |
Completed |
GIS Review
|
No Comments
|
08/05/2019
|
08/05/2019
|
|
Kathy Kraemer
|
|
|
Engineering Review
|
No Comments
|
08/01/2019
|
08/01/2019
|
|
Sue Pyles, P.E.
|
|
|
Planning Review
|
No Comments
|
08/01/2019
|
07/29/2019
|
|
Hector Soto Jr.
|
|
|
GIS Review
|
Corrections
|
08/01/2019
|
07/26/2019
|
|
Kathy Kraemer
|
|
Corrective Action Required
Dedication and statement of ownership cannot be combined. When dedicating the plat, the recorder's office requires the clear use of the word "Dedication"
|
|
|
Planning Review
|
Corrections
|
07/19/2019
|
07/22/2019
|
|
Hector Soto Jr.
|
|
Corrective Action Required
PLAT TITLE. The plat title still needs revision. Revise the plat title to read, Strother Crossing, Lots 4A-4C. Reflect this title correction throughout the plat as necessary.
|
|
Corrective Action Required
GENERAL NOTES. Delete Note #6. It speaks to the required setbacks for the subject property under the standards in effect at this time. However, those standards may or may not continue to be accurate in the future as the City's zoning ordinances change.
|
|
|
GIS Review
|
Corrections
|
07/19/2019
|
07/18/2019
|
|
Kathy Kraemer
|
|
Corrective Action Required
No corrected electronic copy of plat has been submitted, so review cannot be completed.
|
|
|
Engineering Review
|
Corrections
|
07/19/2019
|
07/16/2019
|
|
Sue Pyles, P.E.
|
|
Corrective Action Required
As previously requested, remove ""Covered By The Master Drainage Plan" from Note #5.
|
|
Corrective Action Required
As previously requested, include all easement dimensions.
|
|
Corrective Action Required
There is a small section of 25' Sanitary Sewer Eeasement (by Doc. No. 2007E0028468) shown on the current plat (Strother Crossing 1st Plat, Lots 1-4) at the SW corner of the plat. Please include on this plat as previously requested.
|
|
Corrective Action Required
As previously requested, include easement dedications for all types of proposed easements.
|
|
|
Planning Review
|
Corrections
|
06/26/2019
|
06/24/2019
|
|
Hector Soto Jr.
|
|
Corrective Action Required
PLAT TITLE.
- Change the label above the plat title from "Administrative Plat" to "Minor Plat".
- Revise the plat title to read, Strother Crossing, Lots 4A-4C. Reflect the change throughout the plat as necessary wherever the plat title is referenced.
|
|
Corrective Action Required
ADDRESSES. Label the following lots with their respective addresses: 4A - 2931; 4B - 2951; and 4C - 2911.
|
|
Corrective Action Required
BUILDING LINES. Show and label the 20' building line along the I-470 frontage of all three proposed lots.
|
|
Corrective Action Required
CONTACT INFORMATION. Add the name and address of the developer to the plat.
|
|
Corrective Action Required
LEGAL DESCRIPTION. The legal under the plat title reads that this is "a replat of part of Lot 4...". This is a replat of ALL of Lot 4. Revise.
|
|
Corrective Action Required
STATE PLAN COORDINATES. Label the coordinates for all of the plat corners.
|
|
Corrective Action Required
DISTANCES AND DIRECTIONS. None of the bearings labeled for the plat's outer boundaries (original Lot 4) match those on the existing recorded plat. Add the bearings from the original plat to the new plat and label those bearings as (Plat).
|
|
Corrective Action Required
OIL AND GAS WELLS. Add a note to the plat regarding the presence or absence of any active, inactive or capped oil or gas wells within the plat boundaries. Cite the source of the well information. MoDNR has an online oil and gas well database that can be used as an information source.
|
|
Corrective Action Required
SIDEWALKS.
- Show and label the existing 10' sidewalk along the NE Strother Rd frontage of Lot 4B.
- Add a 5' sidewalk along the NE Independence Ave frontage of Lot 4C.
|
|
Corrective Action Required
RIGHT-OF-WAY WIDTH. Label I-470 as having a variable right-of-width (R/W varies).
|
|
Corrective Action Required
CITY SIGNATURE BLOCK. The signature block and approval certification paragraph above the signature lines are those of a final plat, not a minor plat.
- Revise the approval certification to read, "This is to certify that the minor plat of (name of plat) was submitted to and duly approved pursuant to Chapter 33, Unified Development Ordinance, of the City of Lee's Summit Code of Ordinances."
- Change the signature line for Robert McKay to read, "Ryan A. Elam, PE". Also change the department name/title to read, "Director of Development Services Department".
- Change the City Clerk's name to Trisha Fowler Arcuri.
- Delete the signature line for the Secretary.
|
|
Corrective Action Required
DEDICATION PARAGRAPHS. Add the standard dedication paragraphs found in the sample under Section 7.140.B.21 of the UDO, with the exception of the "Streets" and "Common Area" paragraphs.
|
|
|
GIS Review
|
Corrections
|
06/26/2019
|
06/24/2019
|
|
Kathy Kraemer
|
|
Corrective Action Required
State plane coordinates are missing on the plat corners.
|
|
|
Engineering Review
|
Corrections
|
06/26/2019
|
06/21/2019
|
|
Sue Pyles, P.E.
|
|
Corrective Action Required
Show location of all oil/gas wells, or indicate none are present, and cite the source.
|
|
Corrective Action Required
Remove ""Covered By The Master Drainage Plan" from Note #5.
|
|
Corrective Action Required
Include the easement boundary line between the utility and electrical easements along the north property line.
|
|
Corrective Action Required
Include easement dimensions.
|
|
Corrective Action Required
It appears there is a small section of Sanitary Sewer eeasement at the SW corner of the plat.
|
|
Corrective Action Required
Include easement dedications for all types of proposed easements.
|
|
|