PL2019101
Summit Orchard Lot 4 - Public Water Main
Engineering Plan Review
Engineering Plan Review
Approved
03/11/2019
TOWNSEND SUMMIT LLC
Locations
Contacts
TOWNSEND SUMMIT LLC, Address:1311 MCCORMICK RD STE 470, Phone:(303) 947-2044  
ANDERSON ENGINEERING INC, Address:941 W 141ST TERRACE SUITE A, Phone:(816) 777-0400  
TOWNSEND SUMMIT LLC, Address:1311 MCCORMICK RD STE 470, Phone:(303) 947-2044  
Reviews
Review Type Outcome Est. Completion Date Completed
Engineering Review No Comments 04/19/2019 04/17/2019
Sue Pyles, P.E.
Engineering Review Corrections 04/01/2019 04/02/2019
Sue Pyles, P.E.
Corrective Action Required
04/02/2019

General: • Include Erosion and Sediment Control design for each stage (pre-disturbance, during construction, post-completion) in the plan set. Include standard details for all items shown. • Include a Summary of Quantities table.
Corrective Action Required
04/02/2019

Sheet C002: Please revise the line weights to make the water line more clearly shown.
Corrective Action Required
04/02/2019

Sheet C301-C303: • Include pipe lengths in either Plan or Profile view. • The plans call for boring under Ward Road, but the Profile view seems to show casing pipe. Verify intent, and clarify whether or not there is an existing casing pipe and an existing valve present. • The existing inlet on Ward Road at Sta. 2+15 does not appear to meet the separation requirement of Section 6901.D.1.d.i(b)of the Design and Construction Manual. Please revise as needed. • Show the Fire Hydrant and Gate Valve at Sta. 9+11 in Plan view.
Hearings

There are no hearings for this planning application.

Documents & Images
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New license, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home