Permit Application Status

PRRES20253562


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20253562
Building Permit - Residential
Issued
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. UNCOVERED DECK. ROOF TRUSSES. STOP WORK ORDER generated on 10/28/2025 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 11/06/2025 12:00 AM by username 'Mitchell Schwarz'.
08/21/2025
08/27/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
COULTER@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $4,080.00 $4,080.00 Paid 08/27/2025
Water Meter Fee $791.53 $791.53 Paid 08/27/2025
Sanitary Sewer Development Fee $2,398.00 $2,398.00 Paid 08/27/2025
Right of Way Permit Fee $85.00 $85.00 Paid 08/27/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 08/27/2025
Valuation Fee New Single Family $1,904.50 $1,904.50 Paid 08/27/2025
Parks Impact Fee Residential Zone 2 $1,000.00 $1,000.00 Paid 08/27/2025
Outstanding Fees Amount Paid Owing Date Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid


$450.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Footing Inspection - Residential Pending
Occupancy Inspection - Codes Residential Pending
Erosion Control Inspection Residential Pending
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
11/18/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Sidewalk Inspection Pending 12/22/2025 12/22/2025
Driveway Inspection Pending 12/22/2025 12/22/2025
Misc
Corrective Action Required
12/15/2025
12-15-25 Dustin A, dw has been formed and compacted. Slopes are in compliance. Approved to pour
Underslab Plumbing Inspection - Residential Passed 9/10/2025 9/10/2025 09/10/2025
All Rough Inspection - Residential Partial 9/30/2025 9/30/2025 09/30/2025
Misc
Informational
09/30/2025
Garage portal frame inspection only okay to cover
Sewer Service Inspection - R Passed 10/15/2025 10/15/2025 10/15/2025
Water Service Inspection - R Passed 10/15/2025 10/15/2025 10/15/2025
Gas Service Inspection - Residential Passed 10/21/2025 10/21/2025 10/21/2025
Electrical Service Inspection Failed 10/21/2025 10/21/2025 10/21/2025
Misc
Corrective Action Required
10/21/2025
Ufer ground clams not installed correctly.
All Rough Inspection - Residential Failed 10/22/2025 10/22/2025 10/22/2025
Misc
Informational
09/30/2025
Garage portal frame inspection only okay to cover
Misc
Corrective Action Required
10/22/2025
Inspection denied. Provide gravel entrance to city code
All Rough Inspection - Residential Not Ready 10/24/2025 10/24/2025 10/24/2025
Misc
Informational
10/22/2025
Garage portal frame inspection only okay to cover
Misc
Corrective Action Required
10/22/2025
Inspection denied. Provide gravel entrance to city code/erosion crontrol at front
All Rough Inspection - Residential Not Ready 10/28/2025 10/28/2025 10/28/2025
Misc
Informational
10/24/2025
Garage portal frame inspection only okay to cover
Misc
Corrective Action Required
10/24/2025
Inspection denied. Provide gravel entrance to city code/erosion crontrol at front
Erosion Control Inspection Residential Failed - Stop Work 10/28/2025
DCM5 ESC INSP DENIED
Corrective Action Required
10/28/2025
STOP WORK ISSUED REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. GRAVEL ENTRANCE STILL NOT IN COMPLIANCE
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
10/28/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Erosion Control Inspection Residential Failed 10/31/2025 10/31/2025 10/31/2025
DCM5 ESC INSP DENIED
Resolved
10/31/2025
STOP WORK ISSUED REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. GRAVEL ENTRANCE STILL NOT IN COMPLIANCE
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
10/31/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Misc
Corrective Action Required
10/31/2025
Gravel entrance repaired silt fence is now down
Erosion Control Inspection Residential Not Ready 11/5/2025 11/5/2025 11/05/2025
Misc
Corrective Action Required
10/31/2025
Gravel entrance repaired silt fence is now down Still not done
Erosion Control Inspection Residential Partial 11/6/2025 11/6/2025 11/06/2025
Misc
Resolved
11/06/2025
Gravel entrance repaired silt fence is now down Still not done
Misc
Informational
11/06/2025
Erosion control back in compliance
All Rough Inspection - Residential Failed 11/7/2025 11/7/2025 11/07/2025
Misc
Resolved
11/07/2025
Garage portal frame inspection only okay to cover
Misc
Resolved
11/07/2025
Inspection denied. Provide gravel entrance to city code/erosion crontrol at front
Misc
Corrective Action Required
11/07/2025
All osb/exterior sheathing used for fire blocking not to code Uncover cover roof framing -sister over notched wall studs in garage with full height studs -fireblock from garage furr down to living space fire blocking materials being used not approved -anchor bolts to be in the middle 1/3 of sill plate throughout -anchor bolts to be within 12” of plate breaks but not closer than 7x the diameter of bolt throughout -fire blocking materials at great room windows not approved -fireblock wall space to ceiling space at basement entrance -repair hole in floor of hvac chase -outlet spacing in primary bedroom great than 6’ from entry -no more than 2 NM through plate penetrations. See primary bath, check throughout -seal top plate penetration at primary bath vanity -protect dryer vent 2” below top plate -nail all exterior wall stud corners to code -trusses throughout missing lateral bracing -trusses throughout not nailed together to plans -multiple top plate penetrations throughout 2nd floor. -minimum 3 exterior wall studs in basement -
All Rough Inspection - Residential Not Ready 11/13/2025 11/13/2025 11/13/2025
Misc
Corrective Action Required
11/07/2025
All osb/exterior sheathing used for fire blocking not to code Uncover cover roof framing -sister over notched wall studs in garage with *full height studs* -fireblock wall space into garage furr down fill gaps -anchor bolts to be in the middle 1/3 of sill plate throughout garage and basement -anchor bolts to be within 12” of plate breaks but not closer than 7x the diameter of bolt throughout -fire blocking materials at great room windows not approved -fireblock wall space to ceiling space at basement/2nd floor stairwell entrance foyer -seal top plate penetration at primary bath vanity -protect dryer vent 2” below top plate -nail all exterior wall stud corners to code throughout -missing stud at NE primary bedroom corner (Minimum 3 studs at each exterior wall corner) -multiple top plate penetrations throughout 2nd floor. Check laundry
All Rough Inspection - Residential Failed 11/18/2025 11/18/2025 11/18/2025
Misc
Corrective Action Required
11/13/2025
All exterior sheathing used for fire blocking can not be used and is not to code (see R302.11.1 for approved fireblocking materials) Uncover cover roof framing -fireblock wall space into garage furr down fill gaps -anchor bolts to be in the middle 1/3 of sill plate throughout garage and basement -anchor bolts to be within 12” of plate breaks but not closer than 7x the diameter of bolt throughout -fire blocking materials at great room windows not approved -fireblock wall space to ceiling space at basement/2nd floor stairwell entrance foyer -seal top plate penetration at primary bath vanity -multiple top plate penetrations throughout 2nd floor. Check laundry
Erosion Control Inspection Residential Failed 11/18/2025 11/18/2025
Misc
Resolved
11/18/2025
Erosion control back in compliance
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
11/18/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
All Rough Inspection - Residential Failed 11/24/2025 11/24/2025 11/24/2025
Misc
Corrective Action Required
11/18/2025
All exterior sheathing and 1/2” osb used for fire blocking can not be used and is not to code (see R302.11.1 for approved fireblocking materials) see 2nd floor dead spaces Uncover covered porch roof framing
Electrical Service Inspection Not Ready 11/25/2025 11/25/2025 11/25/2025
Misc
Corrective Action Required
10/21/2025
Ufer ground clams not listed to use with rebar
Electrical Service Inspection Passed 12/1/2025 12/1/2025 12/01/2025
Misc
Resolved
12/01/2025
Ufer ground clams not listed to use with rebar
All Rough Inspection - Residential Not Ready 12/1/2025 12/1/2025 12/01/2025
Misc
Corrective Action Required
11/24/2025
All exterior sheathing and 1/2” osb used for fire blocking can not be used and is not to code (see R302.11.1 for approved fireblocking materials) see 2nd floor hvac chase Address notched truss D1 above front porch
All Rough Inspection - Residential Failed 12/3/2025 12/3/2025 12/03/2025
Misc
Corrective Action Required
12/01/2025
Address notched truss D1 above front porch
All Rough Inspection - Residential Passed 12/11/2025 12/11/2025 12/11/2025
Misc
Resolved
12/11/2025
Address notched truss D1 above front porch
Sidewalk Inspection Partial 12/15/2025 12/15/2025 12/15/2025
Misc
Corrective Action Required
12/15/2025
12-15-25 Dustin A, sw has been formed and compacted. Slopes are in compliance. Approved to pour
Driveway Inspection Partial 12/15/2025 12/15/2025 12/15/2025
Misc
Corrective Action Required
12/15/2025
12-15-25 Dustin A, dw has been formed and compacted. Slopes are in compliance. Approved to pour
Documents & Images
Date Uploaded File Type Document Name
08/21/2025 BY #0350 - PERMIT APP
08/26/2025 Approved Plans APPROVED PLANS
08/26/2025 Plot Plan APPROVED PLOT PLAN
08/26/2025 Approved Plans APPROVED TRUSS LAYOUT
08/26/2025 Approved Plans APPROVED TRUSS PACKAGE
08/27/2025 Permit Codes Residential Plan Review
08/27/2025 Permit DS Building Permit
08/27/2025 Receipt Receipt for transaction:2025-006699
09/05/2025 0360 Bailey Farms Footing- Stamped
09/10/2025 Letter INSPECTION SUMMARY
09/30/2025 Letter INSPECTION SUMMARY
10/15/2025 Letter INSPECTION SUMMARY
10/15/2025 Letter INSPECTION SUMMARY
10/21/2025 Letter INSPECTION SUMMARY
10/21/2025 Letter INSPECTION SUMMARY
10/22/2025 Letter INSPECTION SUMMARY
10/24/2025 Letter INSPECTION SUMMARY
10/28/2025 Letter INSPECTION SUMMARY
10/28/2025 Letter Stop Work Order
11/05/2025 Letter INSPECTION SUMMARY
11/05/2025 Letter INSPECTION SUMMARY
11/06/2025 Letter INSPECTION SUMMARY
11/07/2025 Letter INSPECTION SUMMARY
11/13/2025 Letter INSPECTION SUMMARY
11/18/2025 Letter INSPECTION SUMMARY
11/18/2025 Letter INSPECTION SUMMARY
11/24/2025 Letter INSPECTION SUMMARY
11/25/2025 Letter INSPECTION SUMMARY
12/01/2025 Letter INSPECTION SUMMARY
12/01/2025 Letter INSPECTION SUMMARY
12/02/2025 Engineer Report/Study BY 350 Truss Letter D1 Repair
12/03/2025 Letter INSPECTION SUMMARY
12/11/2025 Letter INSPECTION SUMMARY
12/15/2025 Letter INSPECTION SUMMARY
12/15/2025 Letter INSPECTION SUMMARY
12/15/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home