Permit Application Status

PRRES20253425


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20253425
Building Permit - Residential
Issued
WOODLAND OAKS LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UFINISHED BASEMENT - COVERED PATIO - LOWER PRESSURE SEWER SYSTEM
08/14/2025
08/26/2025
02/15/2026
Locations
Contacts
TRUMARK HOMES, LLC, Address:424 SE MAXWELL DR, Phone:(816) 564-5613  
WOODLAND OAKS LLC, Address:656 BAYBERRY LN STE 101  
MARK A YANCIK, Address:508 nw manor dr  
TRUMARKHOMES.MARK@GMAIL.COM  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,398.00 $2,398.00 Paid 08/26/2025
Right of Way Permit Fee $85.00 $85.00 Paid 08/26/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 08/26/2025
Valuation Fee New Single Family $2,102.51 $2,102.51 Paid 08/26/2025
Parks Impact Fee Residential Zone 2 $1,000.00 $1,000.00 Paid 08/26/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Plot Plan Inspection Pending
Water Service Inspection - R Pending
Occupancy Inspection - Codes Residential Pending
Electrical Service Inspection Pending
Misc
Corrective Action Required
11/12/2025
-Straighten and retighten grounding connection to rebar
Erosion Control Inspection Residential Pending
Misc
Corrective Action Required
11/12/2025
Erosion control is in compliance
All Rough Inspection - Residential Pending
Misc
Corrective Action Required
11/12/2025
**Remove all insulation from floor joist rim -Nail siding to sill plate adjacent to window well; nail siding along vertical edge per code -Provide min 2 anchors for garage steel column -Fb garage duct chase from soffit -Garage west PFH wall anchor shall be within middle 1/3 of plate -Provide R19 at garage ceiling thermal envelope below return air space -Nail hangers above pantry -Provide hangers at (3)2x10 connections above laundry -Support roof ridge and hip rafter above great room -Provide hangers for ceiling beams above master bedroom -Complete electrical to receptacles at foyer and bedroom walls -Fb penetration of dead space adjacent to 2nd floor bathroom tub -Add more support for over cut rafter above 2nd floor bathroom tub -Nail corner studs at bedroom 2 -Install window at bedroom 3 -Provide hangers at ceiling beam connections above bedroom 3 -Nail stud shoe at bedroom 3 bathroom -Provide attic access to roof space above great room and master area -Fb basement bathroom wall from soffit (at penetrations of sheathing) -Move basement half bathroom fan down to ceiling level **DO NOT INSULATE
Erosion Control Inspection Residential Partial 9/8/2025 09/08/2025
Misc
Corrective Action Required
09/08/2025
Erosion control is in compliance
Underslab Plumbing Inspection - Residential Passed 9/8/2025 9/8/2025 09/08/2025
Footing Inspection - Residential Passed 09/08/2025
Informational
09/08/2025
Footing approved by engineer
Erosion Control Inspection Residential Partial 10/2/2025 10/02/2025
Misc
Corrective Action Required
09/08/2025
Erosion control is in compliance
All Rough Inspection - Residential Failed 10/2/2025 10/2/2025 10/02/2025
Misc
Corrective Action Required
10/02/2025
-Garage portal walls only-sheathing nailing ok; however, fasten the 2x4 plate to header with two rows of 16d @ 3" oc; Support timber beam at wall
Piers/Caissons Inspection - Residential Failed 10/13/2025 10/13/2025
Misc
Corrective Action Required
10/13/2025
Remove loose dirt from pier hole. The SE pier hole not straight down but dug at an angle
Sewer Service Inspection - R Passed 10/31/2025 10/31/2025
Piers/Caissons Inspection - Residential Passed 11/3/2025 11/3/2025 11/03/2025
Misc
Resolved
11/03/2025
Remove loose dirt from pier hole. The SE pier hole not straight down but dug at an angle
Electrical Service Inspection Failed 11/12/2025 11/12/2025 11/12/2025
Misc
Corrective Action Required
11/12/2025
-Straighten and retighten grounding connection to rebar
Gas Service Inspection - Residential Passed 11/12/2025 11/12/2025 11/12/2025
Erosion Control Inspection Residential Partial 11/12/2025 11/12/2025
Misc
Corrective Action Required
10/02/2025
Erosion control is in compliance
All Rough Inspection - Residential Failed 11/12/2025 11/12/2025 11/12/2025
Misc
Corrective Action Required
10/02/2025
**Remove all insulation from floor joist rim -Nail siding to sill plate adjacent to window well; nail siding along vertical edge per code -Provide min 2 anchors for garage steel column -Fb garage duct chase from soffit -Garage west PFH wall anchor shall be within middle 1/3 of plate -Provide R19 at garage ceiling thermal envelope below return air space -Nail hangers above pantry -Provide hangers at (3)2x10 connections above laundry -Support roof ridge and hip rafter above great room -Provide hangers for ceiling beams above master bedroom -Complete electrical to receptacles at foyer and bedroom walls -Fb penetration of dead space adjacent to 2nd floor bathroom tub -Add more support for over cut rafter above 2nd floor bathroom tub -Nail corner studs at bedroom 2 -Install window at bedroom 3 -Provide hangers at ceiling beam connections above bedroom 3 -Nail stud shoe at bedroom 3 bathroom -Provide attic access to roof space above great room and master area -Fb basement bathroom wall from soffit (at penetrations of sheathing) -Move basement half bathroom fan down to ceiling level **DO NOT INSULATE
Documents & Images
Date Uploaded File Type Document Name
08/14/2025 Application Form woodland 5 permit application
08/19/2025 Permit Codes Residential Plan Review
08/19/2025 Approved Plans APPROVED PLANS
08/19/2025 Plot Plan APPROVED PLOT PLAN
08/19/2025 Permit Codes Residential Plan Review
08/26/2025 Permit DS Building Permit
08/26/2025 Receipt Receipt for transaction:2025-006652
08/29/2025 3RD Party Insp Report M L Crose 2612 NE Woodland Oak Dr LSMO 3rd Party Footing Inspection Report Pg 1 of 2 8-27-25
08/29/2025 3RD Party Insp Report M L Crose 2612 NE Woodland Oak Dr LSMO 3rd Party Footing Inspection Report Pg 2 of 2 8-27-25
09/08/2025 Letter INSPECTION SUMMARY
09/08/2025 Letter INSPECTION SUMMARY
09/08/2025 Letter INSPECTION SUMMARY
10/02/2025 Letter INSPECTION SUMMARY
10/02/2025 Letter INSPECTION SUMMARY
10/13/2025 Letter INSPECTION SUMMARY
10/31/2025 Letter INSPECTION SUMMARY
11/03/2025 Letter INSPECTION SUMMARY
11/12/2025 Letter INSPECTION SUMMARY
11/12/2025 Letter INSPECTION SUMMARY
11/12/2025 Letter INSPECTION SUMMARY
11/12/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home