Summary
PRRES20253208
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW DUPLEX - FINISHED AND UNFINISHED BASEMENT - REFERENCE PERMIT 20250700 FOR PREVIOUS INSPECTIONS
07/30/2025
09/05/2025
10/06/2025
Locations
Contacts
Site360 LLC, Address:1813 SW Fountain Drive  
JGKELLEY2@GMAIL.COM  
COMFORT SYSTEMS HTG/CLG, Address:128 W Markey Rd, Phone:(816) 322-1013  
ELECTRICAL CONNECTIONS, Address:20112 HOPS CREEK DR, Phone:(816) 838-6946  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Additional Permit Fee $697.00 $697.00 Paid 09/05/2025
Valuation Fee for New Duplex $0.00 $0.00 $0.00 N/A
Not Ready Inspection Fee $75.00 $75.00 Paid 09/22/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sidewalk Inspection Partial 9/8/2025 9/8/2025 09/08/2025
Misc
Informational
09/08/2025
Sidewalk - forms and materials passed pre-inspection.
Sidewalk Inspection Passed 9/8/2025 9/8/2025 09/10/2025
Misc
Informational
09/08/2025
Sidewalk - forms and materials passed pre-inspection.
Misc
Informational
09/10/2025
Sidewalk passed final inspection. Special Note: Contractor picture framed sidewalk. Sidewalk should broom on the entire panel.
Occupancy Inspection - Codes Residential Not Ready 9/22/2025 9/22/2025 09/22/2025
Misc
Corrective Action Required
09/22/2025
Note carried over form previous rated assembly: Unit 207- fire tape attic space, seal all gaps and penetrations (provide ladder to verify) 9/22/25 -Not ready for inspection. Fee assessed. Inspection incomplete. Pay all fees due before occupancy -Provide as graded plot plan including retaining wall -Complete exterior stairs -Garage stairs vary more than 3/8" -Driveway inspection still pending -Install security screws per LS chapter 7 at entry door -Remove all furniture for inspection
Driveway Inspection Passed 9/24/2025 9/24/2025 09/24/2025
Misc
Informational
09/24/2025
Partial on 3/24/25 from previous permit: Pre-inspection Driveway forms and materials appear to meet specification. Driveway passed final inspection.
Occupancy Inspection - Codes Residential Failed 9/25/2025 9/25/2025 09/25/2025
Misc
Corrective Action Required
09/22/2025
-Provide as graded plot plan including retaining wall -Install security screws per LS chapter 7 at entry door -Adjust garage doors to self close and latch -Complete sod at 207 -Secure AC whips within 12" of disconnects -Install box extensions at kitchen receptacles to be within 1/4" of finish material -Install a receptacle within 25' of mechanical unit at 207 -Label non GFCI receptacles in basement -Install anti siphon devices at hose bibs -Max breaker for AC units to be 30 amp -Install hammer arrestors at washing machine shut off valves -Land open electrical under cabinets -Provide 1.5" clearance at handrails -Missing kitchen island receptacle at 205 -Loose receptacle far right of sink in kitchen of 205
Plot Plan Inspection Passed 9/26/2025 09/26/2025
Occupancy Inspection - Codes Residential Failed 10/1/2025 10/1/2025 10/01/2025
Misc
Corrective Action Required
09/25/2025
-Complete sod at 207 -Label non GFCI receptacles in basement
All Rough Inspection - Residential Passed 10/06/2025
Occupancy Inspection - Codes Residential Full C of O 10/6/2025 10/6/2025 10/06/2025
Misc
Resolved
10/06/2025
-Complete sod at 207 -Label non GFCI receptacles in basement
Documents & Images
Date Uploaded File Type Document Name
07/30/2025 Application Form APPLICATION
09/04/2025 Letter LETTER FOR PLANS TO BE USED BY NEW OWNER
09/04/2025 Approved Plans APPROVED PLANS 1
09/04/2025 Approved Plans approved sheet A102
09/04/2025 Approved Plans APPROVED BASEMENT FINISH
09/05/2025 Letter OWNERSHIP DOC
09/05/2025 Permit Codes Residential Plan Review
09/05/2025 Permit DS Building Permit
09/05/2025 Receipt Receipt for transaction: 2025-006931
09/05/2025 Plot Plan APPROVED PLOT PLAN
09/08/2025 Letter INSPECTION SUMMARY
09/10/2025 Letter INSPECTION SUMMARY
09/22/2025 Letter INSPECTION SUMMARY
09/22/2025 Receipt Receipt for transaction:2025-007269
09/24/2025 Letter INSPECTION SUMMARY
09/24/2025 Letter INSPECTION SUMMARY
09/24/2025 AS-GRADED PLOT PLAN LOT #1 092425
09/25/2025 Plot Plan APPROVED AS GRADED PLOT PLAN
09/25/2025 Letter INSPECTION SUMMARY
09/26/2025 Letter INSPECTION SUMMARY
10/01/2025 Letter INSPECTION SUMMARY
10/06/2025 Letter INSPECTION SUMMARY
10/06/2025 Letter Field Certificate of Occupancy
10/06/2025 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home