Permit Application Status

PRRES20252810


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20252810
Building Permit - Residential
Issued
NEW DUPLEX
NEW DUPLEX - ROOF TRUSSES - UNFINISHED BASEMENT STOP WORK ORDER generated on 08/01/2025 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 08/04/2025 12:00 AM by username 'Mitchell Schwarz'.
07/02/2025
07/07/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Not shown for privacy reasons.
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Duplex $2,166.27 $2,166.27 Paid 07/07/2025
Sanitary Sewer Development Fee $4,796.00 $4,796.00 Paid 07/07/2025
Right of Way Permit Fee $85.00 $85.00 Paid 07/07/2025
Water Tap Fee $8,160.00 $8,160.00 Paid 07/07/2025
Water Meter Fee $1,583.06 $1,583.06 Paid 07/07/2025
Parks Impact Fee Residential Zone 2 $1,000.00 $1,000.00 Paid 07/07/2025
Residential Excise Tax Fee $1,240.32 $1,240.32 Paid 07/07/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 10/23/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 10/23/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Plot Plan Inspection Pending
Foundation Inspection - Commercial Pending
Underslab Electrical Inspection - Residential Pending
Occupancy Inspection - Codes Residential Pending
Erosion Control Inspection Residential Pending
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/01/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Install gravel filter
Rated Assembly Inspection Pending
Misc
Corrective Action Required
09/30/2025
Not ready for inspection see all rough
Sewer Service Inspection - R Passed 7/29/2025 7/29/2025 07/29/2025
Water Service Inspection - R Passed 7/31/2025 7/31/2025 07/31/2025
Underslab Plumbing Inspection - Residential Not Ready 8/1/2025 8/1/2025 08/01/2025
Misc
Corrective Action Required
08/01/2025
Inspection denied no gravel entry. Not ready
Erosion Control Inspection Residential Failed 8/1/2025 8/1/2025 08/01/2025
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/01/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Install gravel filter
Footing Inspection - Residential Failed - Stop Work 8/1/2025 8/1/2025 08/01/2025
Misc
Corrective Action Required
08/01/2025
FOOTING POURED WITHOUT INSPECTION STOP WORK ISSED
Footing Inspection - Residential Passed 8/4/2025 8/4/2025 08/04/2025
Misc
Resolved
08/04/2025
FOOTING POURED WITHOUT INSPECTION STOP WORK ISSED
Underslab Plumbing Inspection - Residential Passed 8/5/2025 8/5/2025 08/05/2025
Misc
Resolved
08/05/2025
Inspection denied no gravel entry. Not ready
All Rough Inspection - Residential Passed 8/25/2025 8/25/2025 08/25/2025
All Rough Inspection - Residential Failed 9/25/2025 9/25/2025 09/25/2025
Misc
Informational
09/24/2025
Exterior portal framing okay to cover
Misc
Corrective Action Required
09/25/2025
Inspection denied provide complete set of city stamped plans on site for inspection (plans missing pages)
Gas Service Inspection - Residential Failed 9/25/2025 9/25/2025 09/25/2025
Misc
Corrective Action Required
09/25/2025
Inspection denied provide complete set of city stamped plans on site for inspection (plans missing pages)
Electrical Service Inspection Failed 9/25/2025 9/25/2025 09/25/2025
Misc
Corrective Action Required
09/25/2025
Inspection denied provide complete set of city stamped plans on site for inspection (plans missing pages)
All Rough Inspection - Residential Failed 9/30/2025 9/30/2025 09/30/2025
Misc
Resolved
09/30/2025
Exterior portal framing okay to cover
Misc
Resolved
09/30/2025
Inspection denied provide complete set of city stamped plans on site for inspection (plans missing pages)
Misc
Corrective Action Required
09/30/2025
THROUGHOUT -party wall requires 3/4” air gap -party wall clip spacing not installed to design -fireplace furr out wall will need to be spaced out to allow for gypsum board on party wall -remove vents from roof sheathing within 4’ of party wall and repair holes -missing lateral bracing on multiple trusses -install correct size/install correctly bonding for gas and electrical connections at gas and ufers 1222 -anchor bolts to be in the middle 1/3 of sill plate in garage -move radon pipe so that hangers will not interfere with party wall -missing lib in bath 2 -bath 2 tub installed will not allow for gypsum board at party wall -fireblock front door wall to ceiling space -provide blocking under kitchen per plans(2.34) 1224 -anchor bolts to be in the middle 1/3 of sill plate in garage -anchor bolts to be to be at each plate end/break within 12” but not closer than 7x the diameter of the bolt -missing lib bed 2 closet -bath 2 tub installed will not allow for gypsum board at party wall -provide blocking under kitchen per plans
Gas Service Inspection - Residential Failed 9/30/2025 9/30/2025 09/30/2025
Misc
Resolved
09/30/2025
Inspection denied provide complete set of city stamped plans on site for inspection (plans missing pages)
Misc
Corrective Action Required
09/30/2025
-install correct size/install correctly bonding for gas at gas and ufer
Electrical Service Inspection Failed 9/30/2025 9/30/2025 09/30/2025
Misc
Resolved
09/30/2025
Inspection denied provide complete set of city stamped plans on site for inspection (plans missing pages)
Misc
Corrective Action Required
09/30/2025
-install correct size/install correctly ufers connection
Rated Assembly Inspection Failed 9/30/2025 9/30/2025 09/30/2025
Misc
Corrective Action Required
09/30/2025
Not ready for inspection see all rough
Electrical Service Inspection Passed 10/7/2025 10/7/2025 10/07/2025
Misc
Resolved
10/07/2025
-install correct size/install correctly ufers connection
Gas Service Inspection - Residential Passed 10/7/2025 10/7/2025 10/07/2025
Misc
Resolved
10/07/2025
-install correct size/install correctly bonding for gas at gas and ufer
All Rough Inspection - Residential Failed 10/7/2025 10/7/2025 10/07/2025
Misc
Corrective Action Required
09/30/2025
THROUGHOUT -fireplace furr out wall will need to be spaced out to allow for gypsum board on party wall -repair roof sheathing within 4’ of party wall and repair holes 1222 -move radon pipe hangers so it will not interfere with party wall 1224
All Rough Inspection - Residential Not Ready 10/13/2025 10/13/2025 10/13/2025
Misc
Corrective Action Required
10/07/2025
1222 -move radon pipe and hangers so it will not interfere with party wall 1224
All Rough Inspection - Residential Passed 10/15/2025 10/15/2025 10/15/2025
Misc
Resolved
10/15/2025
1222 -move radon pipe and hangers so it will not interfere with party wall 1224
Documents & Images
Date Uploaded File Type Document Name
07/02/2025 BY #2290 - PERMIT APP
07/07/2025 Plot Plan APPROVED PLOT PLAN
07/07/2025 Approved Plans APPROVED TRUSS LAYOUT
07/07/2025 Approved Plans APPROVED TRUSS PACKET
07/07/2025 Permit Codes Residential Plan Review
07/07/2025 Permit DS Building Permit
07/07/2025 Receipt Receipt for transaction:2025-005270
07/11/2025 Approved Plans APPROVED PLANS
07/29/2025 Letter INSPECTION SUMMARY
07/31/2025 Letter INSPECTION SUMMARY
08/01/2025 Letter INSPECTION SUMMARY
08/01/2025 Letter INSPECTION SUMMARY
08/01/2025 Letter Stop Work Order
08/03/2025 1222-24 SE Windbreak Dr
08/04/2025 Letter INSPECTION SUMMARY
08/05/2025 Letter INSPECTION SUMMARY
08/25/2025 Letter INSPECTION SUMMARY
09/25/2025 Letter INSPECTION SUMMARY
09/25/2025 Letter INSPECTION SUMMARY
09/25/2025 Letter INSPECTION SUMMARY
09/30/2025 Letter INSPECTION SUMMARY
09/30/2025 Letter INSPECTION SUMMARY
09/30/2025 Letter INSPECTION SUMMARY
09/30/2025 Letter INSPECTION SUMMARY
10/07/2025 Letter INSPECTION SUMMARY
10/07/2025 Letter INSPECTION SUMMARY
10/07/2025 Letter INSPECTION SUMMARY
10/13/2025 Letter INSPECTION SUMMARY
10/15/2025 Letter INSPECTION SUMMARY
10/23/2025 Receipt Receipt for transaction:2025-007947
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home