Summary
PRRES20252578
Building Permit - Residential
Issued
DEVES STEVEN & KAREN
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. WALKOUT BASEMENT. COVERED DECK.
06/20/2025
07/03/2025
12/23/2025
Locations
Contacts
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
Joseph Matthew Schartz, Address:PO Box 942, Phone:(816) 524-3855  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
TEAGUE ELECTRIC CONSTRUCTION LLC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
greg@sabhomes.com  
DEVES STEVEN & KAREN, Address:715 SW 15TH CIR  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $4,080.00 $4,080.00 Paid 07/03/2025
Water Meter Fee $791.53 $791.53 Paid 07/03/2025
Sanitary Sewer Development Fee $2,398.00 $2,398.00 Paid 07/03/2025
Right of Way Permit Fee $85.00 $85.00 Paid 07/03/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 07/03/2025
Valuation Fee New Single Family $1,828.17 $1,828.17 Paid 07/03/2025
Parks Impact Fee Residential Zone 3 $1,000.00 $1,000.00 Paid 07/03/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Plot Plan Inspection Pending
Occupancy Inspection - Codes Residential Pending
Sidewalk Inspection Pending
Sewer Service Inspection - R Pending
Misc
Informational
09/19/2025
roughly 165' from foundation.
Underground Electrical Inspection - Residential Pending
Underground Plumbing Inspection - Residential Pending
Misc
Corrective Action Required
09/26/2025
Water line from main home to accessory structure- okay
Erosion Control Inspection Residential Pending
Footing Inspection - Residential Passed 7/25/2025 07/25/2025
Underslab Plumbing Inspection - Residential Passed 7/25/2025 7/25/2025 07/25/2025
All Rough Inspection - Residential Partial 9/2/2025 9/2/2025 09/02/2025
Misc
Corrective Action Required
09/02/2025
Partial inspection only -garage portal frame nailing okay to cover -covered rear deck roofing okay to cover.
Sewer Service Inspection - R Partial 9/19/2025 09/19/2025
Misc
Informational
09/19/2025
roughly 165' from foundation.
Water Service Inspection - R Passed 9/22/2025 9/22/2025 09/22/2025
Underground Plumbing Inspection - Residential Partial 9/26/2025 09/26/2025
Misc
Corrective Action Required
09/26/2025
Water line from main home to accessory structure- okay
Erosion Control Inspection Residential Partial 9/29/2025 09/29/2025
Electrical Service Inspection Failed 10/7/2025 10/7/2025 10/07/2025
Misc
Corrective Action Required
10/07/2025
-provide proper clamp for gas bonding (dissimilar metals)
Gas Service Inspection - Residential Passed 10/7/2025 10/7/2025 10/07/2025
All Rough Inspection - Residential Failed 10/7/2025 10/7/2025 10/07/2025
Misc
Resolved
10/07/2025
Partial inspection only -garage portal frame nailing okay to cover -covered rear deck roofing okay to cover.
Misc
Corrective Action Required
10/07/2025
-provide joist hangers above pantry for joist to lvl -outlet spacing in master suite greater tgsn 6’ at entry -seal top plate penetration right master vanity -fire block wall space to ceiling space in master bath/master closet wall -seal top plate penetration in master toilet room/closet -no more than 2 NM through plate penetrations together master closet, foyer coat closet, bed 3 bath(check throughout) -protect NM in foyer coat closet at ceiling line -bond metallic box above deck(check metallic boxes throughout) -fire blocking into furr downs in basement, when using unfaced insulation it must be packed tightly and securely -missing double joists under master bath -address plans call for beams to rest in beam pocket S wall -missing double LVL above family room -missing double LVL at bed 3 entry -outlet required for wall greater than 2’ see bed 3 and bed 4 -seal penetrations from wall space to ceiling space from pex and electrical in bath3/4 -multiple anchor bolts loose throughout -fire block wall space into furr down in bed 4 closet -provide proper clamp for gas bonding (dissimilar metals)
Electrical Service Inspection Passed 10/9/2025 10/9/2025 10/09/2025
Misc
Resolved
10/09/2025
-provide proper clamp for gas bonding (dissimilar metals)
All Rough Inspection - Residential Failed 10/9/2025 10/9/2025 10/09/2025
Misc
Corrective Action Required
10/07/2025
-provide joist hangers above pantry for joist to lvl -outlet spacing in master suite greater tgsn 6’ at entry -seal top plate penetration right master vanity -fire block wall space to ceiling space in master bath/master closet wall -seal top plate penetration in master toilet room/closet -no more than 2 NM through plate penetrations together master closet, foyer coat closet, bed 3 bath(check throughout) -protect NM in foyer coat closet at ceiling line -bond metallic box above deck(check metallic boxes throughout) -fire blocking into furr downs in basement, when using unfaced insulation it must be packed tightly and securely -missing double joists under master bath -address plans call for beams to rest in beam pocket S wall -missing double LVL above family room -missing double LVL at bed 3 entry -outlet required for wall greater than 2’ see bed 3 and bed 4 -seal penetrations from wall space to ceiling space from pex and electrical in bath3/4 -multiple anchor bolts loose throughout -fire block wall space into furr down in bed 4 closet -provide proper clamp for gas bonding (dissimilar metals)
All Rough Inspection - Residential Failed 10/9/2025 10/9/2025 10/09/2025
Misc
Corrective Action Required
10/09/2025
-fire block wall space to ceiling space in master bath/master closet wall (missing penetration ) Okay to insulate
All Rough Inspection - Residential Passed 10/9/2025 10/9/2025 10/09/2025
Misc
Resolved
10/09/2025
-fire block wall space to ceiling space in master bath/master closet wall (missing penetration ) Okay to insulate
Sewer Service Inspection - R Partial 10/24/2025 (8:00) 10/24/2025 10/24/2025
Misc
Informational
10/24/2025
10-24-25 Dustin A, Sanitary wye was installed 9 1\2 feet down stream from manhole . Contractor will be running tracer wire from connection to sewer stub. Picture uploaded
Documents & Images
Date Uploaded File Type Document Name
06/20/2025 GA-1F - Air Combustion Calcs
06/20/2025 GA-1F - Excise Tax Application
06/20/2025 GA-1F- Permit Application
06/26/2025 Permit Codes Residential Plan Review
07/02/2025 Plot Plan APPROVED PLOT PLAN
07/02/2025 Approved Plans APPROVED PLANS
07/02/2025 Permit Codes Residential Plan Review
07/03/2025 Permit DS Building Permit
07/03/2025 Receipt Receipt for transaction:2025-005212
07/17/2025 Goppert Acres, Lot 1F - footing
07/24/2025 713 SW 15th Cir - soil
07/24/2025 Goppert Acres, Lot 1F - footing
07/25/2025 Letter INSPECTION SUMMARY
07/25/2025 Letter INSPECTION SUMMARY
09/02/2025 Letter INSPECTION SUMMARY
09/22/2025 Letter INSPECTION SUMMARY
09/22/2025 Letter INSPECTION SUMMARY
09/26/2025 Letter INSPECTION SUMMARY
09/29/2025 Letter INSPECTION SUMMARY
10/07/2025 Letter INSPECTION SUMMARY
10/07/2025 Letter INSPECTION SUMMARY
10/07/2025 Letter INSPECTION SUMMARY
10/09/2025 Letter INSPECTION SUMMARY
10/09/2025 Letter INSPECTION SUMMARY
10/09/2025 Letter INSPECTION SUMMARY
10/09/2025 Letter INSPECTION SUMMARY
10/24/2025 713 sw 15th st
10/24/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home