Permit Application Status

PRRES20246297


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20246297
Building Permit - Residential
Issued
WOODLAND OAKS LLC
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. WALKOUT BASEMENT. SUSPENDED STOOP. COVERED DECK.
12/06/2024
12/19/2024
06/11/2025
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
WOODLAND OAKS LLC, Address:656 BAYBERRY LN STE 101  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
FIVE STAR MECHANICAL CONTRACT INC, Address:P O BOX 11964, Phone:(816) 358-4444  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
WALKERCUSTOMHOMESKC@GMAIL.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 12/31/2024
Right of Way Permit Fee $85.00 $85.00 Paid 12/31/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 12/31/2024
Valuation Fee New Single Family $1,746.05 $1,746.05 Paid 12/31/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Occupancy Inspection - Codes Residential Pending
Erosion Control Inspection Residential Pending
Misc
Corrective Action Required
06/26/2025
Erosion control in compliance
All Rough Inspection - Residential Pending
Misc
Corrective Action Required
06/26/2025
-Attach deck beam to each post with two 1/2” through bolts/washers/nuts or equivalent connections -Windows at rear dining exterior wall shall be safety tempered windows **Provide vapor barrier
Gas Service Inspection - Residential Pending
Misc
Corrective Action Required
06/26/2025
-No pressure
Sidewalk Inspection Pending
Misc
Informational
07/30/2025
7-30-25 NS Site visit for a pre-pour inspection and it appears that the sidewalk and driveway meets city standards for pre-pour.
Driveway Inspection Pending 7/30/2025
Misc
Informational
05/13/2025
5-13-25 NS Site visited and it appears that driveway and sidewalk have not been started.
Footing Inspection - Residential Passed 2/10/2025 02/10/2025
Underslab Plumbing Inspection - Residential Failed 2/10/2025 2/10/2025 02/10/2025
Misc
Corrective Action Required
02/10/2025
Inspection denied -provide premise identification -address erosion control inspection issues
Erosion Control Inspection Residential Failed 2/10/2025 2/10/2025 02/10/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/10/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Provide premise Identification -clean street and repair gravel entry -clean storm inlet.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/10/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
02/10/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Erosion Control Inspection Residential Failed 2/26/2025 02/26/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/10/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -REPAIR EROSION CONTROL ALONG STREET -PROVIDE MIN 3/4" AND 6" THICK GRAVEL BED AT LOT ENTRANCE -CLEAN STORM INLET
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
02/10/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Underslab Plumbing Inspection - Residential Failed 2/26/2025 2/26/2025 02/26/2025
Misc
Corrective Action Required
02/10/2025
Inspection denied -address erosion control inspection issues
Erosion Control Inspection Residential Partial 3/4/2025 03/04/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
03/04/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -REPAIR EROSION CONTROL ALONG STREET -PROVIDE MIN 3/4" AND 6" THICK GRAVEL BED AT LOT ENTRANCE -CLEAN STORM INLET
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
03/04/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Misc
Corrective Action Required
03/04/2025
Erosion control in compliance
Underslab Plumbing Inspection - Residential Passed 3/4/2025 3/4/2025 03/04/2025
Misc
Resolved
03/04/2025
Inspection denied -address erosion control inspection issues
Sewer Service Inspection - R Passed 4/8/2025 4/8/2025 04/08/2025
Driveway Inspection Partial 5/14/2025 05/13/2025
Misc
Informational
05/13/2025
5-13-25 NS Site visited and it appears that driveway and sidewalk have not been started.
Erosion Control Inspection Residential Partial 6/17/2025 06/17/2025
Misc
Corrective Action Required
03/04/2025
Erosion control in compliance
Gas Service Inspection - Residential Failed 6/17/2025 06/17/2025
Misc
Corrective Action Required
06/17/2025
-No pressure
Electrical Service Inspection Passed 6/17/2025 06/17/2025
All Rough Inspection - Residential Failed 6/17/2025 6/17/2025 06/17/2025
Misc
Corrective Action Required
06/17/2025
-Attach deck beam to each post with two 1/2” through bolts/washers/nuts or equivalent connections -Protect dryer duct at top plate with BOCA strike plate -Windows at rear dining exterior wall shall be safety tempered windows -Fb basement wall spaces from soffits (bedroom and east wall) -Extend supply air duct above wet bar to ceiling level -Seal ceiling joist return air space above basement bedroom and bathroom -Install 4-stud pack at basement stair wall per plan **OK TO INSULATE
Erosion Control Inspection Residential Partial 6/26/2025 06/26/2025
Misc
Corrective Action Required
06/17/2025
Erosion control in compliance
All Rough Inspection - Residential Failed 6/26/2025 6/26/2025 06/26/2025
Misc
Corrective Action Required
06/17/2025
-Attach deck beam to each post with two 1/2” through bolts/washers/nuts or equivalent connections -Windows at rear dining exterior wall shall be safety tempered windows **Provide vapor barrier
Gas Service Inspection - Residential Failed 6/26/2025 06/26/2025
Misc
Corrective Action Required
06/17/2025
-No pressure
Sidewalk Inspection Partial 7/30/2025 7/30/2025 07/30/2025
Misc
Informational
07/30/2025
7-30-25 NS Site visit for a pre-pour inspection and it appears that the sidewalk and driveway meets city standards for pre-pour.
Documents & Images
Date Uploaded File Type Document Name
12/13/2024 Permit Codes Residential Plan Review
12/18/2024 Plot Plan APPROVED PLOT PLAN
12/18/2024 Application Form 2607 NE Woodland Oaks- LS Residential Permit
12/18/2024 Approved Plans APPROVED PLANS
12/18/2024 Permit Codes Residential Plan Review
12/19/2024 Permit DS Building Permit
12/19/2024 Receipt Receipt for transaction:2024-009612
12/31/2024 Receipt Receipt for transaction:2024-009722
01/29/2025 2607 NEWOODLAND OAKS DR FTG INSP
02/10/2025 Letter INSPECTION SUMMARY
02/10/2025 Letter INSPECTION SUMMARY
02/10/2025 Letter INSPECTION SUMMARY
02/26/2025 Letter INSPECTION SUMMARY
02/26/2025 Letter INSPECTION SUMMARY
03/04/2025 Letter INSPECTION SUMMARY
03/04/2025 Letter INSPECTION SUMMARY
04/08/2025 Letter INSPECTION SUMMARY
04/28/2025 2025_04_14_2607 NE Woodland Oak Dr_LSMO_DPier_Report_Sealed
05/13/2025 Letter INSPECTION SUMMARY
06/17/2025 Letter INSPECTION SUMMARY
06/17/2025 Letter INSPECTION SUMMARY
06/17/2025 Letter INSPECTION SUMMARY
06/17/2025 Letter INSPECTION SUMMARY
06/26/2025 Letter INSPECTION SUMMARY
06/26/2025 Letter INSPECTION SUMMARY
06/26/2025 Letter INSPECTION SUMMARY
07/30/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home