Permit Application Status

PRRES20245915


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20245915
Building Permit - Residential
Issued
NEW DUPLEX
NEW DUPLEX - SUSPENDED SLAB - FINISHED AND UNFINISHED BASEMENT - COVERED PORCH
11/11/2024
12/03/2024
05/13/2025
Locations
Contacts
ROCK CREEK HOMES, Address:6126 METCALF LANE, Phone:(913) 522-1945  
Kevin Guinan, Address:6126 Metcalf Lane  
KEVIN@ROCKCREEKHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
PRIDE SERVICES INC, Address:3842 GEORGIA TERR, Phone:(785) 242-9700  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Duplex $2,574.57 $2,574.57 Paid 12/03/2024
8331507-Sanitary Sewer Development Fee $4,570.00 $4,570.00 Paid 12/03/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 12/03/2024
8331401-Water Tap Fee $7,946.00 $7,946.00 Paid 12/03/2024
8350015-Water Meter Fee $1,496.06 $1,496.06 Paid 12/03/2024
7232302-Residential License Tax Fee $1,240.32 $1,240.32 Paid 12/03/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Plot Plan Inspection Pending
All Rough Inspection - Residential Pending
Foundation Inspection - Commercial Pending
Electrical Service Inspection Pending
Gas Service Inspection - Residential Pending
Rated Assembly Inspection Pending
Occupancy Inspection - Codes Residential Pending
Sidewalk Inspection Pending
Erosion Control Inspection Residential Pending
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
03/18/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Footing Inspection - Residential Failed 12/19/2024 12/19/2024
Miscellaneous Correction
Corrective Action Required
12/19/2024
Footing passed by a third party, but failed because of no address posted on site
Sewer Service Inspection - R Partial 3/6/2025 3/6/2025 03/06/2025
Misc
Informational
03/06/2025
- 1400 Approved only
Sewer Service Inspection - R Passed 3/6/2025 3/6/2025 03/06/2025
Misc
Informational
03/06/2025
- 1400 , 1402 Approved
Footing Inspection - Residential Passed 3/6/2025 03/06/2025
Miscellaneous Correction
Resolved
03/06/2025
Footing passed by a third party, but failed because of no address posted on site
Water Service Inspection - R Partial 3/6/2025 3/6/2025 03/06/2025
Misc
Corrective Action Required
03/06/2025
- PARTIAL POLY OUT OF FOUNDATION 30' BOTH UNITS
Erosion Control Inspection Residential Failed 3/6/2025 03/06/2025
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
03/06/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - REMOVE GRAVEL AND DEBRIS FROM STREET.
Water Service Inspection - R Passed 3/7/2025 3/7/2025 03/07/2025
Misc
Informational
03/07/2025
1400 & 1402
Underslab Electrical Inspection - Residential Passed 3/12/2025 3/12/2025 03/12/2025
Misc
Resolved
03/12/2025
- for 1400 and 1402
Erosion Control Inspection Residential Failed 3/12/2025 03/12/2025
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
03/06/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - REMOVE GRAVEL AND DEBRIS FROM STREET. - REMOVE GRAVEL AND DEBRIS FROM CURBS AND STORM INLETS.
Erosion Control Inspection Residential Failed 3/18/2025 03/18/2025
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
03/18/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - REMOVE GRAVEL AND DEBRIS FROM STREET. - REMOVE GRAVEL AND DEBRIS FROM CURBS AND STORM INLETS.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
03/18/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Underslab Plumbing Inspection - Residential Passed 3/18/2025 3/18/2025 03/18/2025
Suspended Slab Inspection Passed 3/31/2025 03/31/2025
Misc
Informational
03/31/2025
- Third party slab inspection on file.
Documents & Images
Date Uploaded File Type Document Name
11/11/2024 Application Form Application - Lot 46
11/11/2024 Tax Form - Lot 46
11/14/2024 Permit Codes Residential Plan Review
11/21/2024 Approved Plans APPROVED PLANS
11/21/2024 Plot Plan APPROVED PLOT PLAN
11/21/2024 Permit Codes Residential Plan Review
12/03/2024 Permit DS Building Permit
12/03/2024 Receipt Receipt for transaction: 2024-009258
12/18/2024 Lot 46 Footing Inspection
12/19/2024 Letter INSPECTION SUMMARY
03/06/2025 Letter INSPECTION SUMMARY
03/06/2025 Letter INSPECTION SUMMARY
03/06/2025 Letter INSPECTION SUMMARY
03/06/2025 Letter INSPECTION SUMMARY
03/06/2025 Letter INSPECTION SUMMARY
03/07/2025 Letter INSPECTION SUMMARY
03/12/2025 Letter INSPECTION SUMMARY
03/12/2025 Letter INSPECTION SUMMARY
03/18/2025 Letter INSPECTION SUMMARY
03/18/2025 Letter INSPECTION SUMMARY
03/31/2025 2025_03_27_1400-02 SW Winthrop Ter_GSlab_Sealed
03/31/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home