Summary
PRRES20245263
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED PATIO
10/04/2024
10/10/2024
04/06/2025
03/20/2025
Locations
Contacts
ELEVATE DESIGN & BUILD LLC, Address:350 SW LONGVIEW BLVD, Phone:(816) 622-8826  
Elevate Design + Build , Address:350 Longview Blvd.   
Sara Ladd, Address:350 SW Longview Blvd, Phone:(816) 622-8826  
SARA@ELEVATEDESIGNBUILDKC.COM  
5 STAR MECHANICAL, LLC, Address:PO BOX 793, Phone:(816) 679-0375  
ELECTRICAL CONNECTIONS, Address:20112 HOPS CREEK DR, Phone:(816) 838-6946  
S&B Plumbing, Inc., Address:PO Box 101, Phone:(913) 850-3445  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 10/10/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/10/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 10/10/2024
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 10/10/2024
8350015-Water Meter Fee $748.03 $748.03 Paid 10/10/2024
9110078-Valuation Fee New Single Family $1,155.73 $1,155.73 Paid 10/10/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 03/19/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/18/2024 10/18/2024 10/18/2024
Sewer Service Inspection - R Passed 11/1/2024 11/1/2024 11/01/2024
Water Service Inspection - R Passed 11/4/2024 11/4/2024 11/04/2024
Underslab Plumbing Inspection - Residential Passed 11/5/2024 11/5/2024 11/05/2024
Erosion Control Inspection Residential Failed 11/5/2024 11/5/2024 11/05/2024
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
11/05/2024
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
11/05/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. Establish gravel drive
All Rough Inspection - Residential Failed 11/26/2024 11/26/2024 11/26/2024
Misc
Corrective Action Required
11/26/2024
Garage PFH wall inspection only: -Nail sheathing to sill plates and seam blockings
Erosion Control Inspection Residential Partial 11/26/2024 11/26/2024
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
11/26/2024
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
11/05/2024
Erosion control in compliance at time of inspection
All Rough Inspection - Residential Partial 12/3/2024 12/3/2024 12/03/2024
Misc
Resolved
12/03/2024
Garage PFH wall inspection only: -Nail sheathing to sill plates and seam blockings
Misc
Informational
12/03/2024
Portal frame inspection only. Okay to cover
Electrical Service Inspection Failed 12/10/2024 12/10/2024 12/10/2024
Misc
Corrective Action Required
12/10/2024
Identify ufer ground connection at each end
Gas Service Inspection - Residential Passed 12/10/2024 12/10/2024 12/10/2024
All Rough Inspection - Residential Failed 12/10/2024 12/10/2024 12/10/2024
Misc
Resolved
12/10/2024
Portal frame inspection only. Okay to cover
Misc
Corrective Action Required
12/10/2024
-Address rear cspf wall not framing to design. incorrect header size, header does not extend to wall corners -provide smoke/co outside immediate vicinity of bedrooms -identify ufer ground connection at both ends
All Rough Inspection - Residential Failed 12/12/2024 12/12/2024 12/12/2024
Misc
Corrective Action Required
12/10/2024
-Address rear cspf missing plate under header per design and nailed -provide smoke/co outside immediate vicinity of bedrooms (main floor front bedroom needs to be 3’ away from bathroom.
Electrical Service Inspection Passed 12/12/2024 12/12/2024 12/12/2024
Misc
Resolved
12/12/2024
Identify ufer ground connection at each end
All Rough Inspection - Residential Passed 12/13/2024 12/13/2024 12/13/2024
Misc
Resolved
12/13/2024
-Address rear cspf missing plate under header per design and nailed -provide smoke/co outside immediate vicinity of bedrooms (main floor front bedroom needs to be 3’ away from bathroom.
Miscellaneous Inspection Not Ready 12/23/2024 12/23/2024 12/23/2024
Misc
Corrective Action Required
12/23/2024
GB bracing not secured to code. 7” on edges and 7” in field
Miscellaneous Inspection Passed 12/24/2024 12/24/2024 12/24/2024
Misc
Resolved
12/24/2024
GB bracing not secured to code. 7” on edges and 7” in field
Driveway Inspection Failed 1/3/2025 1/3/2025 01/03/2025
Misc
Corrective Action Required
01/03/2025
Misc
Corrective Action Required
01/03/2025
1-3-24 Dustin A, Dw is formed. Aggregate is not compacted and is to shallow. Will need dug out and have min 4 inch of gravel. Recall when corrected for another inspection
Driveway Inspection Partial 1/16/2025 1/16/2025 01/16/2025
Misc
Corrective Action Required
01/03/2025
Misc
Informational
01/16/2025
1-3-24 Dustin A, Dw is formed. Aggregate is not compacted and is to shallow. Will need dug out and have min 4 inch of gravel. Recall when corrected for another inspection 1-16-25 dustin a, dw has been formed and compacted. Approved to pour
Piers/Caissons Inspection - Residential Passed 1/16/2025 1/16/2025 01/16/2025
Driveway Inspection Partial 1/27/2025 1/27/2025 01/23/2025
Misc
Corrective Action Required
01/16/2025
Misc
Informational
01/16/2025
1-3-24 Dustin A, Dw is formed. Aggregate is not compacted and is to shallow. Will need dug out and have min 4 inch of gravel. Recall when corrected for another inspection 1-16-25 dustin a, dw has been formed and compacted. Approved to pour 1-23-25 Jamie S, DW is still covered with blankets, could not preform inspection.
Erosion Control Inspection Residential Passed 03/14/2025
DCM2 ESC DEFICIENT INSTALLATION
Resolved
03/14/2025
Erosion control in compliance at time of inspection
Occupancy Inspection - Codes Residential Failed 3/14/2025 3/14/2025 03/14/2025
Misc
Corrective Action Required
03/14/2025
-pay all fees -stairs at rear patio greater 3/8” difference in rise. -provide spark rings at outlets in kitchen where required -seal penetrations at top of wall at garage doors -missing AFCI and GFCI protection for multiple circuits -
Plot Plan Inspection Passed 3/14/2025 03/14/2025
Driveway Inspection Passed 03/14/2025
Misc
Corrective Action Required
01/23/2025
Misc
Informational
01/23/2025
1-3-24 Dustin A, Dw is formed. Aggregate is not compacted and is to shallow. Will need dug out and have min 4 inch of gravel. Recall when corrected for another inspection 1-16-25 dustin a, dw has been formed and compacted. Approved to pour 1-23-25 Jamie S, DW is still covered with blankets, could not perform inspection. 3-14-25 Dustin A, Dw is poured to city specs. Passed
Occupancy Inspection - Codes Residential Full C of O 3/20/2025 3/20/2025 03/20/2025
Misc
Resolved
03/20/2025
-pay all fees -stairs at rear patio greater 3/8” difference in rise. -provide spark rings at outlets in kitchen where required -seal penetrations at top of wall at garage doors -missing AFCI and GFCI protection for multiple circuits
Documents & Images
Date Uploaded File Type Document Name
10/04/2024 HP 24-10-04 HF 141 - Greystone~ab stamped
10/04/2024 License_Tax_Application-24-10-4
10/04/2024 Residental Permit Application-24-10-4
10/07/2024 Permit Codes Residential Plan Review
10/07/2024 Permit Codes Residential Plan Review
10/08/2024 Permit Codes Residential Plan Review
10/08/2024 Permit Codes Residential Plan Review
10/09/2024 Permit Codes Residential Plan Review
10/09/2024 Permit Codes Residential Plan Review
10/09/2024 Approved Plans APPROVED PLANS
10/09/2024 Approved Plans APPROVED PLOT PLAN
10/10/2024 Permit DS Building Permit
10/10/2024 Permit DS Building Permit
10/10/2024 Receipt Receipt for transaction:2024-008255
10/18/2024 Letter INSPECTION SUMMARY
10/18/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/04/2024 Letter INSPECTION SUMMARY
11/04/2024 Letter INSPECTION SUMMARY
11/04/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
11/26/2024 Letter INSPECTION SUMMARY
11/26/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter INSPECTION SUMMARY
12/10/2024 Letter INSPECTION SUMMARY
12/10/2024 Letter INSPECTION SUMMARY
12/10/2024 Letter INSPECTION SUMMARY
12/10/2024 Letter INSPECTION SUMMARY
12/10/2024 Letter INSPECTION SUMMARY
12/10/2024 Letter INSPECTION SUMMARY
12/10/2024 Letter INSPECTION SUMMARY
12/10/2024 Letter INSPECTION SUMMARY
12/12/2024 Letter INSPECTION SUMMARY
12/13/2024 Letter INSPECTION SUMMARY
12/23/2024 Letter INSPECTION SUMMARY
12/23/2024 Letter INSPECTION SUMMARY
01/03/2025 Letter INSPECTION SUMMARY
01/03/2025 Letter INSPECTION SUMMARY
01/16/2025 Letter INSPECTION SUMMARY
01/16/2025 Letter INSPECTION SUMMARY
01/23/2025 Letter INSPECTION SUMMARY
01/23/2025 Letter INSPECTION SUMMARY
03/13/2025 141 Hook Farm as graded plot plan
03/14/2025 Letter INSPECTION SUMMARY
03/14/2025 Letter INSPECTION SUMMARY
03/14/2025 Letter INSPECTION SUMMARY
03/14/2025 Letter INSPECTION SUMMARY
03/14/2025 Letter INSPECTION SUMMARY
03/18/2025 RENEWAL
03/19/2025 Receipt Receipt for transaction:2025-001645
03/20/2025 Letter INSPECTION SUMMARY
03/20/2025 Letter Codes Final Certificate of Occupancy
03/20/2025 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home