Permit Application Status

PRRES20243943


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20243943
Building Permit - Residential
Issued
CHOYCE LLC
NEW 3 OR 4 FAMILY
NEW TRIPLEX - ROOF TRUSSES (DEF) - FINISHED AND UNFINISHED BASEMENT - COVERED PATIO - TILE ROOF
07/29/2024
12/04/2024
05/24/2025
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
CHOYCE LLC, Address:PO BOX 847  
kevin higdon, Address:po box 847  
KEVIN@HIGDONBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New 3 or 4 Family $4,025.48 $4,025.48 Paid 12/04/2024
8331507-Sanitary Sewer Development Fee $6,855.00 $6,855.00 Paid 12/04/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 12/04/2024
8331401-Water Tap Fee $11,919.00 $11,919.00 Paid 12/04/2024
8350015-Water Meter Fee $2,244.09 $2,244.09 Paid 12/04/2024
7232302-Residential License Tax Fee $1,860.48 $1,860.48 Paid 12/04/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
All Rough Inspection - Residential Pending
Electrical Service Inspection Pending
Gas Service Inspection - Residential Pending
Rated Assembly Inspection Pending
Occupancy Inspection - Codes Residential Pending
Sewer Service Inspection - R Pending
Misc
Corrective Action Required
03/25/2025
Sewer lines for units 720 & 722 only-Trench for the sewer dug right to the footing. Have engineer address. Sewer for 718-OK
Erosion Control Inspection Residential Pending
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/07/2025
Erosion control in compliance
Driveway Inspection Pending
Miscellaneous Correction
Informational
05/13/2025
5-13-25 NS Site visited just checking to see progress and not ready
Erosion Control Inspection Residential Failed 2/4/2025 02/04/2025
Misc
Corrective Action Required
02/04/2025
Overall, erosion control is in compliance; however, repair erosion control where damaged by fallen trees
Footing Inspection - Residential Passed 2/4/2025 2/4/2025 02/04/2025
Informational
02/04/2025
Patio column pads formed at same time as footing
Erosion Control Inspection Residential Failed 3/25/2025 03/25/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/04/2025
EROSION CONTROL REQUIRED ALONG THE STREET AND AT STORM INLET. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Sewer Service Inspection - R Failed 3/25/2025 3/25/2025 03/25/2025
Misc
Corrective Action Required
03/25/2025
Sewer lines for units 720 & 722 only-Trench for the sewer dug right to the footing. Have engineer address.
Sewer Service Inspection - R Failed 3/25/2025 3/25/2025 03/25/2025
Misc
Corrective Action Required
03/25/2025
Sewer lines for units 720 & 722 only-Trench for the sewer dug right to the footing. Have engineer address. Sewer for 718-OK
Underslab Plumbing Inspection - Residential Failed 3/26/2025 3/25/2025 03/25/2025
Misc
Corrective Action Required
03/25/2025
Lav drain cannot be used to wet-vent both the water closet and shower trap. Each trap in a wet-vented configuration must individually connect to the horizontal drain
Water Service Inspection - R Passed 3/26/2025 3/26/2025 03/26/2025
Erosion Control Inspection Residential Partial 4/7/2025 04/07/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/25/2025
Erosion control in compliance
Underslab Electrical Inspection - Residential Passed 4/7/2025 4/7/2025 04/07/2025
Underslab Plumbing Inspection - Residential Failed 4/7/2025 4/7/2025 04/07/2025
Misc
Corrective Action Required
03/25/2025
Lav drain cannot be used to wet-vent both the water closet and shower trap. Each trap in a wet-vented configuration must individually connect to the horizontal drain
Underslab Plumbing Inspection - Residential Passed 4/8/2025 4/8/2025 04/08/2025
Misc
Resolved
04/08/2025
Lav drain cannot be used to wet-vent both the water closet and shower trap. Each trap in a wet-vented configuration must individually connect to the horizontal drain
Driveway Inspection Partial 5/14/2025 05/13/2025
Miscellaneous Correction
Informational
05/13/2025
5-13-25 NS Site visited just checking to see progress and not ready
Documents & Images
Date Uploaded File Type Document Name
08/01/2024 Permit Codes Residential Plan Review
08/01/2024 Approved Plans APPROVED PLANS
11/25/2024 Permit Codes Residential Plan Review
12/02/2024 Plot Plan APPROVED PLOT PLAN
12/02/2024 Application Form APPLICATION
12/02/2024 Application Form EXCISE TAX APP.
12/04/2024 Permit Codes Residential Plan Review
12/04/2024 Permit DS Building Permit
12/04/2024 Receipt Receipt for transaction:2024-009336
02/04/2025 Letter INSPECTION SUMMARY
02/04/2025 Letter INSPECTION SUMMARY
03/25/2025 Letter INSPECTION SUMMARY
03/25/2025 Letter INSPECTION SUMMARY
03/25/2025 Letter INSPECTION SUMMARY
03/25/2025 Letter INSPECTION SUMMARY
03/26/2025 Engineer Report/Study 718 Lone Hill
03/26/2025 Letter INSPECTION SUMMARY
03/27/2025 Letter DS Building Permit
04/07/2025 Letter INSPECTION SUMMARY
04/07/2025 Letter INSPECTION SUMMARY
04/07/2025 Letter INSPECTION SUMMARY
04/08/2025 Letter INSPECTION SUMMARY
05/13/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home