Summary
PRRES20243685
Building Permit - Residential
Certificate of Occupancy
SUMMIT VIEW FARMS DEVELOPMENT GROUP LLC
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. COVERED PATIO. STOP WORK ORDER generated on 08/15/2024 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 08/19/2024 12:00 AM by username 'Mitchell Schwarz'.
07/17/2024
08/08/2024
01/21/2025
05/07/2025
Locations
Contacts
JW Thomas LLC, Address:14704 S Hutt rd  
Jeffrey Boehm, Address:14704 S Hutt rd, Phone:(816) 588-3193  
COMFORT SYSTEMS HTG/CLG, Address:128 W Markey Rd, Phone:(816) 322-1013  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
jeff@jw-thomas.com  
SUMMIT VIEW FARMS DEVELOPMENT GROUP LLC, Address:13450 E STATE ROUTE 150  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 08/08/2024
8350015-Water Meter Fee $748.03 $748.03 Paid 08/08/2024
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 08/08/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 08/08/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 08/08/2024
9110078-Valuation Fee New Single Family $2,221.84 $2,221.84 Paid 08/08/2024
Outstanding Fees Amount Paid Owing Date Paid
9110080-Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid


$75.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed - Stop Work 8/15/2024 08/15/2024
Misc
Corrective Action Required
08/15/2024
Footing poured without erosion control, no inspection performed
Erosion Control Inspection Residential Partial 8/19/2024 08/19/2024
Underslab Plumbing Inspection - Residential Passed 8/26/2024 8/26/2024 08/26/2024
Sewer Service Inspection - R Passed 8/30/2024 08/30/2024
Water Service Inspection - R Partial 9/3/2024 9/3/2024 09/03/2024
Misc
Corrective Action Required
09/03/2024
- Partial, poly out of foundation
Water Service Inspection - R Passed 9/4/2024 9/4/2024 09/04/2024
Misc
Resolved
09/04/2024
- Partial, poly out of foundation
Erosion Control Inspection Residential Failed 10/14/2024 10/14/2024 10/14/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/14/2024
10-14-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Silt fence is down in areas and storm inlet needs to be cleaned out
Erosion Control Inspection Residential Partial 10/17/2024 10/17/2024 10/17/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/14/2024
10-14-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Silt fence is down in areas and storm inlet needs to be cleaned out 10-17-24 Dustin A, corrected
Footing Inspection - Residential Passed 11/4/2024 11/04/2024
Misc
Resolved
11/04/2024
Footing poured without erosion control, no inspection performed
Misc
Informational
11/04/2024
David P. Ainsworth, P.E. THIRD PARTY INSPECTOR
All Rough Inspection - Residential Not Ready 11/4/2024 11/4/2024 11/04/2024
Misc
Corrective Action Required
11/04/2024
INSPECTION DENIED NOT READY NO CITY STAMPED PLANS ON SIGHT (No plans at all)
Electrical Service Inspection Passed 11/6/2024 11/6/2024 11/06/2024
Gas Service Inspection - Residential Passed 11/6/2024 11/6/2024 11/06/2024
All Rough Inspection - Residential Failed 11/6/2024 11/6/2024 11/06/2024
Misc
Resolved
11/06/2024
INSPECTION DENIED NOT READY NO CITY STAMPED PLANS ON SIGHT (No plans at all)
Misc
Corrective Action Required
11/06/2024
- top plate in mud room doesn’t have minimum 24” overlap. Strap and provide at least 4 nail each side - nail off studs at exterior corner of pantry top and bottom - Check return venting at wine rack/ shelving - Missing joist hangers for triple LVL at foyer/closet - Fire block top plate at foyer/ powder room - Fire block top of chase in hearth room right side - Purlin struts to be 4’ O.C. - Hip joist not supported above bedroom 3 - Material used for fire blocking in bedroom 3 chase next to stairs not approved - Protect DWV with nova plate not electrical strike plate in upstairs laundry - Strap top plate at North side bedroom 2 less than minimum overlap - Strap top plate of master bedroom at 3” and 2” DWV with correct strapping ( 6” either side of opening with 4 nails each side on bearings walls - Nail triple stud pack together both under double LVL at master closet - Fire block penetration top plate South East wall rec room - Fire block South wall top plate left of window - No ductwork for basement bathroom vent - Tighten anchor bolts through out ( garage, stairs landing, basement) -
All Rough Inspection - Residential Failed 11/6/2024 11/06/2024
Misc
Corrective Action Required
11/06/2024
revised - top plate in mud room doesn’t have minimum 24” overlap. Strap and provide at least 4 nail each side - nail off studs at exterior corner of pantry top and bottom - Check return venting at wine rack/ shelving - Missing joist hangers for triple LVL at foyer/closet - Fire block top plate at foyer/ powder room - Fire block top of chase in hearth room right side - Purlin struts to be 4’ O.C. - Hip joist not supported above bedroom 3 - Material used for fire blocking in bedroom 3 chase next to stairs not approved - Protect DWV with nova plate not electrical strike plate in upstairs laundry - Strap top plate at North side bedroom 2 less than minimum overlap - Strap top plate of master bedroom at 3” and 2” DWV with correct strapping ( 6” either side of opening with 4 nails each side on bearings walls - Nail triple stud pack together both under double LVL at master closet - Fire block penetration top plate South East wall rec room - Fire block South wall top plate left of window - No ductwork for basement bathroom vent - Tighten anchor bolts through out ( garage, stairs landing, basement) -R602.7.5 Support for headers, 12 ft. span at main floor slider required to have 2 king studs adjacent to each end of header.
All Rough Inspection - Residential Failed 11/13/2024 11/13/2024 11/13/2024
Misc
Corrective Action Required
11/06/2024
- Strap top plate at North side bedroom 2 less than minimum overlap - Fire block penetration top plate South East wall rec room ( second floor stairs wall )
All Rough Inspection - Residential Passed 11/14/2024 11/14/2024 11/14/2024
Misc
Resolved
11/14/2024
- Strap top plate at North side bedroom 2 less than minimum overlap - Fire block penetration top plate South East wall rec room ( second floor stairs wall )
Driveway Inspection Failed 11/22/2024 11/22/2024 11/22/2024
Misc
Corrective Action Required
11/22/2024
11-22-24 Dustin A, DW is formed, Aggregate was less then an inch in spots, Standing water in corner. Not compacted. Failed 11-22-24 Dustin A, Contractor dug it out , no compacter on site, Must recall. Fail
Driveway Inspection Partial 11/22/2024 11/22/2024 11/22/2024
Misc
Corrective Action Required
11/22/2024
11-22-24 Dustin A, DW is formed, Aggregate was less then an inch in spots, Standing water in corner. Not compacted. Failed 11-22-24 Dustin A, Contractor dug it out , no compacter on site, Must recall. Fail 11-22-24 Dustin A, DW has bee corrected. Approved to pour
Driveway Inspection Passed 12/2/2024 12/2/2024 12/02/2024
Misc
Corrective Action Required
11/22/2024
11-22-24 Dustin A, DW is formed, Aggregate was less then an inch in spots, Standing water in corner. Not compacted. Failed 11-22-24 Dustin A, Contractor dug it out , no compacter on site, Must recall. Fail 11-22-24 Dustin A, DW has bee corrected. Approved to pour 12-2-24 Dustin A, DW is poured to city spec, Passed
Occupancy Inspection - Codes Residential Failed 4/18/2025 04/18/2025
Misc
Corrective Action Required
04/18/2025
Door to garage needs self closure -garage handrail needs to be graspable -1st bedroom, lower window must be tempered within 18” of floor -fireplace breaker in panel needs lockout -egress well ladders, to first step to be no more than 18” from ground -outdoor ac unit supply whip taken out of ground and secured to house
Plot Plan Inspection Passed 04/18/2025
Erosion Control Inspection Residential Passed 5/7/2025 05/07/2025
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/17/2024
10-14-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Silt fence is down in areas and storm inlet needs to be cleaned out 10-17-24 Dustin A, corrected
Occupancy Inspection - Codes Residential Full C of O 5/7/2025 5/7/2025 05/07/2025
Misc
Resolved
05/07/2025
Documents & Images
Date Uploaded File Type Document Name
07/19/2024 License_Tax_Application lot 90 (1)
07/19/2024 Residental Permit Application lot 90
07/25/2024 Permit Codes Residential Plan Review
08/06/2024 Plot Plan APPROVED PLOT PLAN
08/06/2024 Approved Plans APPROVED PLANS
08/06/2024 Permit Codes Residential Plan Review
08/08/2024 Permit DS Building Permit
08/08/2024 Receipt Receipt for transaction: 2024-006707
08/15/2024 Letter Stop Work Order
08/18/2024 ML Crose 3111 SW Summit View Trail LSMO Footing Inspection Report 8-14-24_compressed
08/19/2024 Letter INSPECTION SUMMARY
08/26/2024 Letter INSPECTION SUMMARY
08/30/2024 Letter INSPECTION SUMMARY
09/03/2024 Letter INSPECTION SUMMARY
09/04/2024 Letter INSPECTION SUMMARY
09/04/2024 Letter INSPECTION SUMMARY
10/14/2024 Letter INSPECTION SUMMARY
10/14/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
11/04/2024 Letter INSPECTION SUMMARY
11/04/2024 Letter INSPECTION SUMMARY
11/04/2024 Letter INSPECTION SUMMARY
11/06/2024 Letter INSPECTION SUMMARY
11/06/2024 Letter INSPECTION SUMMARY
11/06/2024 Letter INSPECTION SUMMARY
11/13/2024 Letter INSPECTION SUMMARY
11/14/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
12/02/2024 Letter INSPECTION SUMMARY
04/18/2025 Letter INSPECTION SUMMARY
04/18/2025 Letter INSPECTION SUMMARY
05/07/2025 Letter Codes Final Certificate of Occupancy
05/07/2025 Letter Field Certificate of Occupancy
05/07/2025 Letter INSPECTION SUMMARY
05/07/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents