Summary
PRRES20242933
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ENG FLOOR SYSTEM - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
06/07/2024
06/27/2024
12/10/2024
06/27/2025
Locations
Contacts
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST, Phone:(816) 470-0074  
Erin Skinner, Address:1314 SW Market Street  
PERMITTING@JFECONSTRUCTION.COM  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 06/27/2024
Right of Way Permit Fee $85.00 $85.00 Paid 06/27/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 06/27/2024
Water Tap Fee $3,760.00 $3,760.00 Paid 06/27/2024
Water Meter Fee $680.46 $680.46 Paid 06/27/2024
Valuation Fee New Single Family $1,679.56 $1,679.56 Paid 06/27/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 12/05/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/8/2024 10/8/2024 10/08/2024
Misc
Informational
10/08/2024
Approved by Al Hermans on 10/7/24
Erosion Control Inspection Residential Partial 10/8/2024 10/8/2024 10/08/2024
Misc
Informational
10/08/2024
10/8/24 -In compliance at time of inspection
Underslab Plumbing Inspection - Residential Failed 10/24/2024 10/24/2024 10/24/2024
Misc
Corrective Action Required
10/24/2024
-Correct erosion control and backfill around foundation for inspection
Erosion Control Inspection Residential Failed 10/24/2024 10/24/2024 10/24/2024
Misc
Informational
10/08/2024
10/8/24 -In compliance at time of inspection
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/24/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Extend silt fence to street and angle ends at entry uphill -Clean debris from storm inlet
Erosion Control Inspection Residential Failed 10/28/2024 10/24/2024
Misc
Resolved
10/24/2024
10/8/24 -In compliance at time of inspection
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/24/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Extend silt fence to street and angle ends at entry uphill -Clean debris from storm inlet
Sewer Service Inspection - R Passed 10/28/2024 10/28/2024 10/28/2024
Water Service Inspection - R Partial 10/28/2024 10/28/2024
Miscellaneous Correction
Informational
10/28/2024
PEX has been ran about 25 feet out from the foundation towards the street and is okay to cover This is a partial pass only
Water Service Inspection - R Passed 10/29/2024 10/29/2024 10/29/2024
Miscellaneous Correction
Resolved
10/29/2024
PEX has been ran about 25 feet out from the foundation towards the street and is okay to cover This is a partial pass only
Erosion Control Inspection Residential Partial 10/29/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
10/29/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Extend silt fence to street and angle ends at entry uphill -Clean debris from storm inlet
Underslab Plumbing Inspection - Residential Passed 11/7/2024 11/7/2024 11/07/2024
Misc
Resolved
11/07/2024
-Correct erosion control and backfill around foundation for inspection
Erosion Control Inspection Residential Partial 11/7/2024 11/7/2024 11/07/2024
Underslab Electrical Inspection - Residential Passed 11/7/2024 11/7/2024 11/07/2024
All Rough Inspection - Residential Failed 11/21/2024 11/21/2024 11/21/2024
Miscellaneous Correction
Corrective Action Required
11/21/2024
11/21/24 *Inspection for exterior garage PFH and dining CS-PF: -Solid block and nail horizontal seams at PFH -Splices in sheathing at CS-PF must be in middle 24" of panel height
Erosion Control Inspection Residential Failed 11/21/2024 11/21/2024 11/21/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
11/21/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Maintain silt fence -Remove trash and debris from street and storm inlet
Erosion Control Inspection Residential Failed 11/26/2024 11/26/2024 11/26/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
11/21/2024
11/21/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Maintain silt fence -Remove trash and debris from street and storm inlet
DCM5 ESC INSP DENIED
Corrective Action Required
11/26/2024
11/26/24 REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
All Rough Inspection - Residential Failed 11/26/2024 11/26/2024 11/26/2024
Miscellaneous Correction
Corrective Action Required
11/21/2024
11/21/24 *Inspection for exterior garage PFH and dining CS-PF: -Solid block and nail horizontal seams at PFH -Splices in sheathing at CS-PF must be in middle 24" of panel height 11/26/24 -Inspection denied due to deficient erosion control as noted on 11/21/24
Erosion Control Inspection Residential Partial 11/27/2024 11/27/2024 11/27/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
11/27/2024
11/21/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Maintain silt fence -Remove trash and debris from street and storm inlet
DCM5 ESC INSP DENIED
Resolved
11/27/2024
11/26/24 REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
All Rough Inspection - Residential Not Ready 11/27/2024 11/27/2024 11/27/2024
Miscellaneous Correction
Corrective Action Required
11/26/2024
11/21/24 *Inspection for exterior garage PFH and dining CS-PF: -Solid block and nail horizontal seams at PFH 11/27/24 -Seams at PFH still not blocked and nailed
All Rough Inspection - Residential Failed 12/2/2024 12/2/2024 12/02/2024
Miscellaneous Correction
Corrective Action Required
11/27/2024
12/2/24 Garage portal OK - Dining room CS-PF sheeting nailing at header not complete.
All Rough Inspection - Residential Failed 12/2/2024 12/02/2024
Miscellaneous Correction
Informational
12/02/2024
12/2/24 Garage portal OK - Dining room CS-PF OK
Erosion Control Inspection Residential Failed 2/5/2025 2/5/2025 02/05/2025
Misc
Corrective Action Required
02/05/2025
-Clean silt and debris from storm inlet -Protect storm inlet by proper means (gutter buddy needs needs replaced and separated from inlet with cinder blocks)
Electrical Service Inspection Passed 2/5/2025 2/5/2025 02/05/2025
Gas Service Inspection - Residential Passed 2/5/2025 2/5/2025 02/05/2025
All Rough Inspection - Residential Failed 2/5/2025 2/5/2025 02/05/2025
Miscellaneous Correction
Informational
12/02/2024
-Tighten anchor bolt at single car bay return wall -Hip truss over notched at lvl in living room -Fireblock top of exterior fireplace. Use approved material -Roof support strut over 45 degrees above entry -Provide min 1” clearance at b vent in master closet top plates -Provide 16g structural straps at cut top plate for hvac, extend 6” each way and nail with min (4) 10d nails each side -Sister over notched stud behind basement shower (egress window king stud) -Missing third stud at exterior corner bed 3, install and nail 12" oc -Seal gap at ceiling line fire blocking at dwv in shared bathroom -Missing third stud at exterior corner mechanical room, install and nail 12" oc -Strap top plate lapping less than 24" at exterior corner of mechanical room -Protect service panel from water lines above per R3405.3 -Seal penetration in return air joist space at floor outlet above basement living area
Erosion Control Inspection Residential Failed 2/10/2025 2/10/2025 02/10/2025
Misc
Corrective Action Required
02/05/2025
-Protect storm inlet by proper means (gutter buddy needs needs replaced and separated from inlet with cinder blocks)
All Rough Inspection - Residential Failed 2/10/2025 2/10/2025 02/10/2025
Miscellaneous Correction
Informational
02/05/2025
-Strap top plate lapping less than 24" at exterior corner of mechanical room-THIS IS AT THE EXTERIOR CORNER. THE BOTTOM TOP PLATE IS ROUGHLY 2" LONG.
All Rough Inspection - Residential Partial 2/11/2025 2/11/2025 02/11/2025
Miscellaneous Correction
Resolved
02/11/2025
-Strap top plate lapping less than 24" at exterior corner of mechanical room-THIS IS AT THE EXTERIOR CORNER. THE BOTTOM TOP PLATE IS ROUGHLY 2" LONG.
All Rough Inspection - Residential Passed 02/11/2025
Erosion Control Inspection Residential Partial 02/11/2025
Misc
Corrective Action Required
02/10/2025
-Protect storm inlet by proper means (gutter buddy needs needs replaced and separated from inlet with cinder blocks)
Erosion Control Inspection Residential Partial 02/11/2025
Misc
Corrective Action Required
02/11/2025
In compliance at time of inspection
Driveway Inspection Partial 3/17/2025 3/17/2025 03/17/2025
Misc
Informational
03/17/2025
3-17-25 BR Driveway is formed up with aggregate is place and compacted ready for concrete.
Driveway Inspection Passed 03/19/2025
Misc
Informational
03/17/2025
3-17-25 BR Driveway is formed up with aggregate is place and compacted ready for concrete. 03/19/25 Wednesday JMJ Driveway passed final inspection.
Plot Plan Inspection Failed 5/9/2025 05/09/2025
Misc
Corrective Action Required
05/09/2025
-Provide engineer plans for retaining wall over 4’ -uncover covered manhole -grading N side of driveway incomplete
Occupancy Inspection - Codes Residential Failed 5/15/2025 5/15/2025 05/15/2025
Misc
Corrective Action Required
05/15/2025
-Complete sod, splash blocks etc. -Obtain lawn irrigation permit and backflow certificate -Wet rated receptacles required at all exterior receptacles -Garage door must self close and latch -Install (2) 1/2" through bolts at deck post to beam connections -Install light fixture at kitchen
Plot Plan Inspection Passed 05/15/2025
Misc
Resolved
05/15/2025
-Provide engineer plans for retaining wall over 4’ -uncover covered manhole -grading N side of driveway incomplete
Occupancy Inspection - Codes Residential Failed 5/23/2025 5/23/2025 05/23/2025
Misc
Resolved
05/23/2025
-Complete sod, splash blocks etc.
Misc
Corrective Action Required
05/23/2025
- add sod, splash blocks ect
Occupancy Inspection - Codes Residential Full C of O 6/27/2025 6/27/2025 06/27/2025
Misc
Resolved
06/27/2025
- add sod, splash blocks ect
Documents & Images
Date Uploaded File Type Document Name
06/07/2024 WR187 - Permit App
06/07/2024 WR187 - Tax App
06/11/2024 Permit Codes Residential Plan Review
06/13/2024 Permit Codes Residential Plan Review
06/13/2024 Plot Plan APPROVED PLOT PLAN
06/27/2024 Approved Plans APPROVED PLANS
06/27/2024 Permit Codes Residential Plan Review
06/27/2024 Permit DS Building Permit
06/27/2024 Receipt Receipt for transaction:2024-005259
09/26/2024 Approved Plans pier plan detail
10/08/2024 Footing-2218 NW Killarney Ln_
10/08/2024 Letter INSPECTION SUMMARY
10/08/2024 Letter INSPECTION SUMMARY
10/08/2024 2218 nw killarney ln_pier insp_2024-10-04
10/24/2024 Letter INSPECTION SUMMARY
10/24/2024 Letter INSPECTION SUMMARY
10/28/2024 Letter INSPECTION SUMMARY
10/28/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
11/07/2024 Letter INSPECTION SUMMARY
11/07/2024 Letter INSPECTION SUMMARY
11/07/2024 Letter INSPECTION SUMMARY
11/12/2024 2218 NW Killarney Ln_ALL SLAB INSP_2024-11-08
11/20/2024 Approved Plans APPROVED I JOIST PLAN
11/21/2024 Letter INSPECTION SUMMARY
11/21/2024 Letter INSPECTION SUMMARY
11/26/2024 Letter INSPECTION SUMMARY
11/26/2024 Letter INSPECTION SUMMARY
11/27/2024 Letter INSPECTION SUMMARY
11/27/2024 Letter INSPECTION SUMMARY
12/02/2024 Letter INSPECTION SUMMARY
12/02/2024 Letter INSPECTION SUMMARY
12/05/2024 Receipt Receipt for transaction:2024-009360
02/05/2025 Letter INSPECTION SUMMARY
02/05/2025 Letter INSPECTION SUMMARY
02/05/2025 Letter INSPECTION SUMMARY
02/05/2025 Letter INSPECTION SUMMARY
02/10/2025 2218 NW Killarney Lane_Framing Evaluation Report_2-7-25
02/10/2025 Letter INSPECTION SUMMARY
02/10/2025 Letter INSPECTION SUMMARY
02/11/2025 Letter INSPECTION SUMMARY
02/11/2025 Letter INSPECTION SUMMARY
02/11/2025 Letter INSPECTION SUMMARY
02/11/2025 Letter INSPECTION SUMMARY
03/17/2025 Letter INSPECTION SUMMARY
03/19/2025 Letter INSPECTION SUMMARY
03/19/2025 Letter INSPECTION SUMMARY
05/08/2025 LOT 187 ASBUILT
05/08/2025 Plot Plan APPROVED AS GRADED PLOT PLAN
05/09/2025 Letter INSPECTION SUMMARY
05/14/2025 JFE 2218 NW Killarney Ln Final Letter
05/14/2025 Approved Plans APPROVED RETAINING WALL PLAN
05/15/2025 Letter INSPECTION SUMMARY
05/15/2025 Letter INSPECTION SUMMARY
06/27/2025 Letter Codes Final Certificate of Occupancy
06/27/2025 Letter Field Certificate of Occupancy
06/27/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home