Permit Application Status

PRRES20242729


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20242729
Building Permit - Residential
Issued
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 07/23/2024 12:00 AM by username 'Alex Fischer'. STOP WORK ORDER removed on 07/24/2024 12:00 AM by username 'Kyle Beard'. STOP WORK ORDER generated on 09/20/2024 12:00 AM by username 'Kyle Beard'. STOP WORK ORDER removed on 09/24/2024 12:00 AM by username 'Kyle Beard'.
05/29/2024
06/11/2024
12/04/2024
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
kevin higdon, Address:po box 847  
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
KEVIN@HIGDONBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 06/11/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 06/11/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 06/11/2024
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 06/11/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 06/11/2024
9110078-Valuation Fee New Single Family $1,936.61 $1,936.61 Paid 06/11/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Misc
Informational
12/02/2024
11-22-24 Dustin A, DW is formed and compacted . Gravel was less then 4 inch but contractor corrected while i was there. Approved to pour. 12-2-24 Dustin A, DW is poured, slopes is in compliance . Cannot pass due to forms still on
Sidewalk Inspection Pending
Misc
Informational
12/02/2024
11-22-24 Dustin A, SW is formed and compacted . Gravel was less then 4 inch but contractor corrected while i was there. Approved to pour. Slopes are in compliance 12-2-24 Dustin A, SW is poured, one panel is out of compliance near storm box, white cure is applied poorly. forms still on. Fail
Occupancy Inspection - Codes Residential Pending
Misc
Corrective Action Required
04/22/2025
-CLEAN STORM INLET -provide issued lawn irrigation permit -address pending sidewalk and driveway inspection -gfci needed under kitchen sink -gfci needed in laundry room -label the breaker panel to corresponding breaker -provide afci protection as required by code section 210.12 -provide lockouts for all hardwired appliance circuits -receptacle at wet bar is tripping on it own -secondary locking device on basement slider is missing -flood light not installed
Erosion Control Inspection Residential Pending
Sewer Service Inspection - R Failed 7/22/2024 07/22/2024
Miscellaneous Correction
Corrective Action Required
07/22/2024
Sewer passed and is okay to cover Sewer failed on inspection report because the footing was never passed
Water Service Inspection - R Failed 7/22/2024 07/22/2024
Miscellaneous Correction
Corrective Action Required
07/22/2024
PEX has been run about 20 feet out from the foundation and is okay to cover Water failed because the footing report was never uploaded
Erosion Control Inspection Residential Failed 7/23/2024 07/23/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/23/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Sewer Service Inspection - R Passed 7/24/2024 07/24/2024
Miscellaneous Correction
Resolved
07/24/2024
Sewer passed and is okay to cover Sewer failed on inspection report because the footing was never passed
Footing Inspection - Residential Passed 7/24/2024 07/24/2024
Miscellaneous Correction
Informational
07/24/2024
Footing passed by a third party Exterior piers were not mentioned in footing inspection
Water Service Inspection - R Passed 7/23/2024 7/24/2024 07/24/2024
Miscellaneous Correction
Resolved
07/24/2024
PEX has been run about 20 feet out from the foundation and is okay to cover Water failed because the footing report was never uploaded
Underslab Plumbing Inspection - Residential Passed 7/23/2024 7/25/2024 07/25/2024
Misc
Resolved
07/25/2024
Erosion Control Inspection Residential Partial 7/25/2024 07/25/2024
Misc
Informational
07/25/2024
-Erosion control in compliance at time of inspection
Erosion Control Inspection Residential Failed 9/12/2024 09/12/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
09/12/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/12/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Erosion control measures at the street curb are torn down and no longer serves its intended use and needs to be repaired or replaced. Erosion control measures protecting the pond is down in the middle and needs to be repaired or replaced Full lot clean up of liter needs to be done This is the second letter sent about erosion control . Please address erosion control before a stop work is placed on this permit
Piers/Caissons Inspection - Residential Failed 9/12/2024 09/12/2024
Miscellaneous Correction
Informational
09/12/2024
Two exterior deck piers were passed by a third party Pier inspection failed due to erosion control stating that no more inspections will be completed until erosion control has been addressed and passed inspection 09/12/24. KBEARD
Erosion Control Inspection Residential Failed - Stop Work 9/20/2024 09/20/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
09/20/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Erosion control measures at the street curb are torn down and no longer serves its intended use and needs to be repaired or replaced. Erosion control measures protecting the pond is down in the middle and needs to be repaired or replaced Full lot clean up of liter needs to be done This is the second letter sent about erosion control . Please address erosion control before a stop work is placed on this permit
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/20/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Erosion control measures at the street curb are torn down and no longer serves its intended use and needs to be repaired or replaced. Erosion control measures protecting the pond is down in the middle and needs to be repaired or replaced Full lot clean up of liter needs to be done This is the second letter sent about erosion control . Please address erosion control before a stop work is placed on this permit (This is a copy of the last inspection completed on 09/12/2024) KBEARD 09/20/24 time 11:25
Erosion Control Inspection Residential Partial 9/24/2024 09/24/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
09/24/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Erosion control measures at the street curb are torn down and no longer serves its intended use and needs to be repaired or replaced. Erosion control measures protecting the pond is down in the middle and needs to be repaired or replaced Full lot clean up of liter needs to be done This is the second letter sent about erosion control . Please address erosion control before a stop work is placed on this permit (This is a copy of the last inspection completed on 09/12/2024) KBEARD 09/20/24 time 11:25
Miscellaneous Correction
Informational
09/24/2024
Full erosion control measures are in place and must be maintained until CofO
Gas Service Inspection - Residential Passed 9/27/2024 9/27/2024 09/27/2024
Piers/Caissons Inspection - Residential Passed 10/30/2024 10/30/2024
Miscellaneous Correction
Resolved
10/30/2024
Two exterior deck piers were passed by a third party Pier inspection failed due to erosion control stating that no more inspections will be completed until erosion control has been addressed and passed inspection 09/12/24. KBEARD
Erosion Control Inspection Residential Partial 10/30/2024 10/30/2024
Miscellaneous Correction
Informational
09/24/2024
Full erosion control measures are in place and must be maintained until CofO
Electrical Service Inspection Passed 10/30/2024 10/30/2024
All Rough Inspection - Residential Failed 10/30/2024 10/30/2024 10/30/2024
Miscellaneous Correction
Corrective Action Required
10/30/2024
3917 SW Flintrock. All rough POST ADDRESS Install PFH anchor washers and bolts Garage anchor bolts must be installed in the middle 1/3 of the bottom plate Nail all garage corners to code Two studs in garage east exterior wall are broken/split and do not serve its intended purpose Purlin strut above garage to attic access hatch has a span of 9 feet. Plans are every 4 feet on center Secure electrical within 6 feet of attic access hatch N/W corner of office top plate does not tie in together Electrical nail guard is needed in stud by gas range Nails are missing in joist hanger to LVL above kitchen island Great room N/E corner 2x6 top plate is not tied into 2x4 top plate Block exterior snow step flashing above great room to master suite Secure 14/2 wire at fireplace south side Purlins and struts are not installed at rafters above entry and stairs Electrical nail guards are needed in master suite west wall by entry door Fire block top plate in master bathroom at shower Electrical nail guard is needed in master closet top plate S/W corner Latterly secure electrical in basement HVAC/Ibeam raceway Basement anchor bolts need to be in the middle 1/3 of bottom plate N/W corner of basement at foundation has one stud scabbed on to a short stud and one stud that was over 1/3 notched out for an anchor bolt. Both studs need to be sistered Basement game area is missing some studs in the 7 and 8 stud packs Nail N/W corner of bedroom 3 to code Bedroom 2 window anchor bolts just hold down 1 of the 2 bottom plates Back deck beams to post connections are not competed with proper fasteners No further inspections until address is posted
Erosion Control Inspection Residential Partial 11/7/2024 11/07/2024
Miscellaneous Correction
Informational
10/30/2024
Full erosion control measures are in place and must be maintained until CofO
All Rough Inspection - Residential Failed 11/7/2024 11/7/2024 11/07/2024
Miscellaneous Correction
Resolved
11/07/2024
3917 SW Flintrock. All rough POST ADDRESS Install PFH anchor washers and bolts Garage anchor bolts must be installed in the middle 1/3 of the bottom plate Nail all garage corners to code Two studs in garage east exterior wall are broken/split and do not serve its intended purpose Purlin strut above garage to attic access hatch has a span of 9 feet. Plans are every 4 feet on center Secure electrical within 6 feet of attic access hatch N/W corner of office top plate does not tie in together Electrical nail guard is needed in stud by gas range Nails are missing in joist hanger to LVL above kitchen island Great room N/E corner 2x6 top plate is not tied into 2x4 top plate Block exterior snow step flashing above great room to master suite Secure 14/2 wire at fireplace south side Purlins and struts are not installed at rafters above entry and stairs Electrical nail guards are needed in master suite west wall by entry door Fire block top plate in master bathroom at shower Electrical nail guard is needed in master closet top plate S/W corner Latterly secure electrical in basement HVAC/Ibeam raceway Basement anchor bolts need to be in the middle 1/3 of bottom plate N/W corner of basement at foundation has one stud scabbed on to a short stud and one stud that was over 1/3 notched out for an anchor bolt. Both studs need to be sistered Basement game area is missing some studs in the 7 and 8 stud packs Nail N/W corner of bedroom 3 to code Bedroom 2 window anchor bolts just hold down 1 of the 2 bottom plates Back deck beams to post connections are not competed with proper fasteners No further inspections until address is posted
Miscellaneous Correction
Corrective Action Required
11/07/2024
3917 SW Flintrock. All rough (2) -Latterly secure electrical in basement HVAC/Ibeam raceway -N/W corner of basement at foundation has one stud scabbed on to a short stud and one stud that was over 1/3 notched out for an anchor bolt. Both studs need to be sistered (need full height sistering) -Basement game area is missing some studs in the 7 and 8 stud packs
All Rough Inspection - Residential Passed 11/12/2024 11/12/2024 11/12/2024
Miscellaneous Correction
Resolved
11/12/2024
3917 SW Flintrock. All rough (2) -Latterly secure electrical in basement HVAC/Ibeam raceway -N/W corner of basement at foundation has one stud scabbed on to a short stud and one stud that was over 1/3 notched out for an anchor bolt. Both studs need to be sistered (need full height sistering) -Basement game area is missing some studs in the 7 and 8 stud packs
Driveway Inspection Partial 11/22/2024 11/22/2024 11/22/2024
Misc
Informational
11/22/2024
11-22-24 Dustin A, DW is formed and compacted . Gravel was less then 4 inch but contractor corrected while i was there. Approved to pour.
Sidewalk Inspection Partial 11/22/2024 11/22/2024 11/22/2024
Misc
Informational
11/22/2024
11-22-24 Dustin A, SW is formed and compacted . Gravel was less then 4 inch but contractor corrected while i was there. Approved to pour. Slopes are in compliance
Driveway Inspection Partial 12/2/2024 12/2/2024 12/02/2024
Misc
Informational
11/22/2024
11-22-24 Dustin A, DW is formed and compacted . Gravel was less then 4 inch but contractor corrected while i was there. Approved to pour. 12-2-24 Dustin A, DW is poured, slopes is in compliance . Cannot pass due to forms still on
Sidewalk Inspection Failed 12/2/2024 12/2/2024 12/02/2024
Misc
Informational
11/22/2024
11-22-24 Dustin A, SW is formed and compacted . Gravel was less then 4 inch but contractor corrected while i was there. Approved to pour. Slopes are in compliance 12-2-24 Dustin A, SW is poured, one panel is out of compliance near storm box, white cure is applied poorly. forms still on. Fail
Plot Plan Inspection Passed 4/22/2025 04/22/2025
Erosion Control Inspection Residential Failed 4/22/2025 04/22/2025
Miscellaneous Correction
Resolved
04/22/2025
Full erosion control measures are in place and must be maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/22/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. CLEAN STORM INLET
Occupancy Inspection - Codes Residential Failed 4/22/2025 4/22/2025 04/22/2025
Misc
Corrective Action Required
04/22/2025
-CLEAN STORM INLET -provide issued lawn irrigation permit -address pending sidewalk and driveway inspection -gfci needed under kitchen sink -gfci needed in laundry room -label the breaker panel to corresponding breaker -provide afci protection as required by code section 210.12 -provide lockouts for all hardwired appliance circuits -receptacle at wet bar is tripping on it own -secondary locking device on basement slider is missing -flood light not installed
Erosion Control Inspection Residential Partial 4/24/2025 4/24/2025 04/24/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/24/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. CLEAN STORM INLET
Documents & Images
Date Uploaded File Type Document Name
05/29/2024 Application Form Lees Summit Residental Permit Application 525 ne sienna
05/29/2024 exciseapplication 525 ne sienna lot 27
05/29/2024 LOT 170 FINAL
05/29/2024 NPV170 Spec - Sealed Plans (May 6, 2024)
05/30/2024 Permit Codes Residential Plan Review
06/06/2024 LOT 170 CITY
06/07/2024 Plot Plan APPROVED PLOT PLAN
06/07/2024 Permit Codes Residential Plan Review
06/11/2024 NPV170 Spec - Sealed Plans (June 5, 2024)
06/11/2024 Approved Plans APPROVED PLANS
06/11/2024 Permit Codes Residential Plan Review
06/11/2024 Permit DS Building Permit
06/11/2024 Receipt Receipt for transaction:2024-004607
06/19/2024 Engineer Report/Study ENGINEER SOILS REPORT
07/22/2024 Letter INSPECTION SUMMARY
07/22/2024 Letter INSPECTION SUMMARY
07/23/2024 Letter INSPECTION SUMMARY
07/23/2024 Letter Stop Work Order
07/24/2024 Letter INSPECTION SUMMARY
07/24/2024 Letter INSPECTION SUMMARY
07/24/2024 Letter INSPECTION SUMMARY
07/24/2024 3917 SW FLINTROCK DR FTG INSP
07/25/2024 Letter INSPECTION SUMMARY
07/25/2024 Letter INSPECTION SUMMARY
09/11/2024 2024_09_10_NAS_Dpiers_FECO_Sealed
09/12/2024 Letter INSPECTION SUMMARY
09/12/2024 Letter INSPECTION SUMMARY
09/20/2024 Letter Stop Work Order
09/24/2024 Letter INSPECTION SUMMARY
09/27/2024 Letter INSPECTION SUMMARY
10/30/2024 Letter INSPECTION SUMMARY
10/30/2024 Letter INSPECTION SUMMARY
10/30/2024 Letter INSPECTION SUMMARY
10/30/2024 Letter INSPECTION SUMMARY
11/07/2024 Letter INSPECTION SUMMARY
11/07/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
12/02/2024 Letter INSPECTION SUMMARY
12/02/2024 Letter INSPECTION SUMMARY
12/02/2024 Letter INSPECTION SUMMARY
04/21/2025 Letter Codes 140 Day Letter
04/22/2025 Letter INSPECTION SUMMARY
04/22/2025 Letter INSPECTION SUMMARY
04/22/2025 Letter INSPECTION SUMMARY
04/24/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home