Permit Application Status

PRRES20242565


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20242565
Building Permit - Residential
Certificate of Occupancy
DOMAIN TIMBERLAKE MULTISTATE LLC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. WALKOUT BASEMENT. UNCOVERED DECK. ROOF TRUSSES.
05/20/2024
06/07/2024
11/20/2024
12/27/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
DOMAIN TIMBERLAKE MULTISTATE LLC, Address:590 MADISON AVE FL 13TH  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
TYLER@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,460.83 $1,460.83 Paid 06/07/2024
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 06/07/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 06/07/2024
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 06/07/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 06/07/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 06/07/2024
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 12/04/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/04/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/09/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/3/2024 07/03/2024
Sewer Service Inspection - R Passed 7/3/2024 7/3/2024 07/03/2024
Water Service Inspection - R Passed 7/8/2024 7/8/2024 07/08/2024
Underslab Plumbing Inspection - Residential Passed 7/11/2024 7/11/2024 07/11/2024
All Rough Inspection - Residential Failed 8/21/2024 8/21/2024 08/21/2024
Misc
Corrective Action Required
08/21/2024
portal inspection only 2x plate under heard required
All Rough Inspection - Residential Failed 9/11/2024 9/11/2024 09/11/2024
Misc
Corrective Action Required
08/21/2024
2x plate under heard required Exterior nailing of pfh okay
All Rough Inspection - Residential Failed 9/24/2024 9/24/2024 09/24/2024
Misc
Resolved
09/24/2024
Garage portal inspection only 2x plate under heard required Exterior nailing of pfh okay
Misc
Corrective Action Required
09/24/2024
-anchor bolts to be in the middle 1/3 of sill plate and tight -address stud bored to close to edge at service panel in garage -provide attic access for space above single car garage -CSPF missing plate under header in primary bedroom -CSPF missing plate under header at great room rear wall -strap top plate at bed 3 closet exterior wall where lapped less than 24” -lib in bath 2 not to plans length -address foyer/garage load bearing wall not built to code and missing hold downs for trusses. Have engineer address -missing TBE4 at girder truss in garage -nail girder trusses together to plans -rear basement wall NE not framed to CSPF specifications -anchor bolts to be within 12” of plate breaks not closer than 7x the diameter of the bolt -missing stud at NW and NE basement exterior wall corners -address over notched exterior wall stud at future basement bath -address over bored floor joist under bath 2
Electrical Service Inspection Passed 9/24/2024 9/24/2024 09/24/2024
Erosion Control Inspection Residential Failed 10/1/2024 10/01/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/01/2024
DEFICIENT EROSION CONTROL INSTALLATION. RESTORE EROSION CONTROL AT THE BACK SIDE OF LOT NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Gas Service Inspection - Residential Failed 10/1/2024 10/1/2024 10/01/2024
Misc
Corrective Action Required
10/01/2024
Provide pressure gauge with range no more than 30 psi
All Rough Inspection - Residential Failed 10/1/2024 10/1/2024 10/01/2024
Misc
Corrective Action Required
09/24/2024
-anchor bolts to be in the middle 1/3 of sill plate and tight **At east garage PFH wall, anchor shall be located in middle 1/3 of sill plate -address foyer/garage load bearing wall not built to code and missing hold downs for trusses. Have engineer address **Build wall with double top plate under pt 17 of C03 trusses and tie down trusses to wall -Install TBE4 hold down at west end of A04 girder truss per plan -rear basement wall NE not framed to CSPF specifications -address over bored floor joist under bath 2 **Electrician please properly redo the grounding to rebar
All Rough Inspection - Residential Not Ready 10/7/2024 10/7/2024 10/07/2024
Misc
Corrective Action Required
10/01/2024
-anchor bolts to be in the middle 1/3 of sill plate and tight **At east garage PFH wall, anchor shall be located in middle 1/3 of sill plate -rear basement wall NE not framed to CSPF specifications -address over bored floor joist under bath 2 **Electrician please properly redo the grounding to rebar
Piers/Caissons Inspection - Residential Passed 11/20/2024 11/20/2024 11/20/2024
Sidewalk Inspection Partial 11/20/2024 11/20/2024 11/20/2024
Misc
Informational
11/20/2024
11-20-24 Dustin A, SW has been formed and compacted and slopes are in compliance. Approved to pour
Driveway Inspection Partial 11/20/2024 11/20/2024 11/20/2024
Misc
Informational
11/20/2024
11-20-24 Dustin A, DW and curb have been formed and compacted, Approved to pour
All Rough Inspection - Residential Failed 11/26/2024 11/26/2024 11/26/2024
Misc
Resolved
11/26/2024
-anchor bolts to be in the middle 1/3 of sill plate and tight **At east garage PFH wall, anchor shall be located in middle 1/3 of sill plate -rear basement wall NE not framed to CSPF specifications -address over bored floor joist under bath 2 **Electrician please properly redo the grounding to rebar
Miscellaneous Correction
Corrective Action Required
11/26/2024
anchor bolts to be in the middle 1/3 of sill plate and tight **At east garage PFH wall, anchor shall be located in middle 1/3 of sill plate (only one anchor bolt was exposed) -rear basement wall NE not framed to CSPF specifications (strap along west side of header is not fully fastened) - Tie basement NE corner together from the 3 inch gap -address over bored floor joist under bath 2 ( plans are not on site to verify bathroom 2) **Electrician please properly redo the grounding to rebar
Gas Service Inspection - Residential Passed 11/26/2024 11/26/2024 11/26/2024
Misc
Resolved
11/26/2024
Provide pressure gauge with range no more than 30 psi
Driveway Inspection Passed 11/27/2024 11/27/2024 11/27/2024
Misc
Informational
11/20/2024
11-20-24 Dustin A, DW and curb have been formed and compacted, Approved to pour 11-27-24 Dustin A, DW iss pouredd to city pecs. Pass
Sidewalk Inspection Passed 11/27/2024 11/27/2024 11/27/2024
Misc
Informational
11/20/2024
11-20-24 Dustin A, SW has been formed and compacted and slopes are in compliance. Approved to pour 11-27-24 Dustin A, sw is poured to city specs and slopes are in compliance. Pass
All Rough Inspection - Residential Passed 12/2/2024 12/2/2024 12/02/2024
Miscellaneous Correction
Resolved
12/02/2024
anchor bolts to be in the middle 1/3 of sill plate and tight **At east garage PFH wall, anchor shall be located in middle 1/3 of sill plate (only one anchor bolt was exposed) -rear basement wall NE not framed to CSPF specifications (strap along west side of header is not fully fastened) - Tie basement NE corner together from the 3 inch gap -address over bored floor joist under bath 2 ( plans are not on site to verify bathroom 2) **Electrician please properly redo the grounding to rebar
Occupancy Inspection - Codes Residential Failed 12/6/2024 12/6/2024 12/06/2024
Misc
Corrective Action Required
12/06/2024
-sod -splash blocks and sump pump discharge to extend 36” from foundation -will check water meter at time of sod. Ensure 14”-18” from top of meter to well ring lid -outlets in garage to be gfci protected or single pull receptacle and labeled -address deck post to beam connections
Plot Plan Inspection Passed 12/6/2024 12/06/2024
Occupancy Inspection - Codes Residential Ready for Temp CO 12/9/2024 12/9/2024 12/09/2024
Misc
Corrective Action Required
12/06/2024
-sod -splash blocks and sump pump discharge to extend 36” from foundation -will check water meter at time of sod. Ensure 14”-18” from top of meter to well ring lid
Erosion Control Inspection Residential Passed 12/27/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
12/27/2024
DEFICIENT EROSION CONTROL INSTALLATION. RESTORE EROSION CONTROL AT THE BACK SIDE OF LOT NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Full C of O 12/27/2024 12/27/2024 12/27/2024
Misc
Resolved
12/27/2024
-sod -splash blocks and sump pump discharge to extend 36” from foundation -will check water meter at time of sod. Ensure 14”-18” from top of meter to well ring lid
Documents & Images
Date Uploaded File Type Document Name
05/24/2024 Permit Codes Residential Plan Review
06/07/2024 Approved Plans APPROVED PLANS
06/07/2024 Plot Plan APPROVED PLOT PLAN
06/07/2024 Approved Plans APPROVED TRUSS PACKAGE
06/07/2024 Approved Plans APPROVED TRUSS LAYOUT
06/07/2024 Permit Codes Residential Plan Review
06/07/2024 Permit DS Building Permit
06/07/2024 Receipt Receipt for transaction:2024-004528
06/07/2024 Application Form H4 #161 - PERMIT APP
06/20/2024 3RD Party Insp Report THIRD PARTY FOOTING INSPECTION
07/03/2024 Letter INSPECTION SUMMARY
07/03/2024 Letter INSPECTION SUMMARY
07/08/2024 Letter INSPECTION SUMMARY
07/11/2024 Letter INSPECTION SUMMARY
08/21/2024 Letter INSPECTION SUMMARY
09/11/2024 Letter INSPECTION SUMMARY
09/24/2024 Letter INSPECTION SUMMARY
09/24/2024 Letter INSPECTION SUMMARY
10/01/2024 Letter INSPECTION SUMMARY
10/01/2024 Letter INSPECTION SUMMARY
10/01/2024 Letter INSPECTION SUMMARY
10/07/2024 Letter INSPECTION SUMMARY
11/20/2024 Letter INSPECTION SUMMARY
11/20/2024 Letter INSPECTION SUMMARY
11/20/2024 Letter INSPECTION SUMMARY
11/26/2024 Engineer Report/Study FLOOR JOIST ENIGNEER LETTER
11/26/2024 Letter INSPECTION SUMMARY
11/26/2024 Letter INSPECTION SUMMARY
11/27/2024 Letter INSPECTION SUMMARY
11/27/2024 Letter INSPECTION SUMMARY
12/02/2024 Letter INSPECTION SUMMARY
12/04/2024 Receipt Receipt for transaction:2024-009313
12/06/2024 Letter INSPECTION SUMMARY
12/06/2024 Letter INSPECTION SUMMARY
12/09/2024 Letter INSPECTION SUMMARY
12/09/2024 Certificate/License Codes Temporary Certificate of Occupancy
12/09/2024 Receipt Receipt for transaction:2024-009396
12/27/2024 Letter INSPECTION SUMMARY
12/27/2024 Letter Field Certificate of Occupancy
12/27/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home