Permit Application Status

PRRES20242469


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20242469
Building Permit - Residential
Temporary Occupancy
DOMAIN TIMBERLAKE MULTISTATE LLC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. UNCOVERED PATIO. ROOF TRUSSES.
05/15/2024
06/13/2024
12/03/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
DOMAIN TIMBERLAKE MULTISTATE LLC, Address:590 MADISON AVE FL 13TH  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
TYLER@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 06/13/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 06/13/2024
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 06/13/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 06/13/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 06/13/2024
9110078-Valuation Fee New Single Family $1,656.60 $1,656.60 Paid 06/13/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/04/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/04/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/04/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/09/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/09/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/13/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/13/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/13/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Erosion Control Inspection Residential Pending
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/03/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM5 ESC INSP DENIED
Corrective Action Required
12/03/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Occupancy Inspection - Codes Residential Pending 4/12/2025
Misc
Corrective Action Required
03/17/2025
Bring water meter well lid to grade.
Footing Inspection - Residential Passed 7/3/2024 07/03/2024
Sewer Service Inspection - R Passed 7/3/2024 7/3/2024 07/03/2024
Water Service Inspection - R Passed 7/8/2024 7/8/2024 07/08/2024
Underslab Plumbing Inspection - Residential Failed 7/16/2024 7/16/2024 07/16/2024
Misc
Corrective Action Required
07/16/2024
No floor drain installed
Underslab Plumbing Inspection - Residential Not Ready 7/17/2024 7/17/2024 07/17/2024
Misc
Corrective Action Required
07/16/2024
No floor drain installed Still not done
Erosion Control Inspection Residential Failed 7/19/2024 07/19/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/19/2024
Repair erosion control at front left side of lot
Underslab Plumbing Inspection - Residential Passed 7/19/2024 7/19/2024 07/19/2024
Misc
Resolved
07/19/2024
All Rough Inspection - Residential Failed 8/20/2024 8/20/2024 08/20/2024
Misc
Corrective Action Required
08/20/2024
-Garage portal frame nailing okay -trusses for front porch okay to cover -engineered bracing at front porch/NE Corner of home not correct Not a complete inspection only portal and porch
Erosion Control Inspection Residential Failed 9/30/2024 09/30/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
09/30/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/30/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED RE- ESTABLIST EROSION CONTROL AT FRONT OF LOT
Electrical Service Inspection Passed 9/30/2024 9/30/2024 09/30/2024
All Rough Inspection - Residential Failed 9/30/2024 9/30/2024 09/30/2024
Misc
Corrective Action Required
08/20/2024
-Garage portal frame nailing okay -trusses for front porch okay to cover -engineered bracing at front porch/NE Corner of home not correct Not a complete inspection only portal and porch
Misc
Corrective Action Required
09/30/2024
I’m Fb = Fire block/ draft stop - Nail off siding at North East corner - Nail off all exterior corners studs to plans throughout - Fur out gas line in garage - Fb gaps at top plate in HVAC chase garage - Fb rim penetration at gas line garage - Install HD12 hold down device at stairs - Complete ductwork to vent at powder room main floor - Address top plate at entry wall no tied in - Protect DWV at entry closet - (4) stud pack not nailed to code at entry closet - Address over bored top plate of bearings wall at main floor power room - Minimum of 3 studs required at all exterior corners at stairs - Fb top of chase at bedroom 2 - Complete vent ductwork bathroom 2 - Provide roof boots - Land electrical wiring hanging in second floor hallway - Fb top plate at double wall primary bathroom shower - Complete vents ductwork at both vents at primary bathroom - Protect DWV at primary bathroom toilet with boca plate - Protect DWV at primary bathroom vanity sill plate with boca plate
Gas Service Inspection - Residential Passed 9/30/2024 9/30/2024 09/30/2024
All Rough Inspection - Residential Not Ready 10/1/2024 10/1/2024 10/01/2024
Misc
Corrective Action Required
09/30/2024
INSPECTION DENIED / NOT READY CHECKED FIRST 5 ITEMS CALLED OUT, NONE COMPLETED
Misc
Corrective Action Required
09/30/2024
Fb = Fire block/ draft stop - Nail off siding at North East corner - Nail off all exterior corners studs to plans throughout - Fur out gas line in garage - Fb gaps at top plate in HVAC chase garage - Fb rim penetration at gas line garage - Install HD12 hold down device at stairs - Complete ductwork to vent at powder room main floor - Address top plate at entry wall no tied in - Protect DWV at entry closet - (4) stud pack not nailed to code at entry closet - Address over bored top plate of bearings wall at main floor power room - Minimum of 3 studs required at all exterior corners at stairs - Fb top of chase at bedroom 2 - Complete vent ductwork bathroom 2 - Provide roof boots - Land electrical wiring hanging in second floor hallway - Fb top plate at double wall primary bathroom shower - Complete vents ductwork at both vents at primary bathroom - Protect DWV at primary bathroom toilet with boca plate - Protect DWV at primary bathroom vanity sill plate with boca plate
All Rough Inspection - Residential Passed 10/7/2024 10/7/2024 10/07/2024
Misc
Resolved
10/07/2024
INSPECTION DENIED / NOT READY CHECKED FIRST 5 ITEMS CALLED OUT, NONE COMPLETED
Misc
Resolved
10/07/2024
Fb = Fire block/ draft stop - Nail off siding at North East corner - Nail off all exterior corners studs to plans throughout - Fur out gas line in garage - Fb gaps at top plate in HVAC chase garage - Fb rim penetration at gas line garage - Complete ductwork to vent at powder room main floor - Address top plate at entry wall no tied in - Protect DWV at entry closet - (4) stud pack not nailed to code at entry closet - Address over bored top plate of bearings wall at main floor power room - Minimum of 3 studs required at all exterior corners at stairs - Fb top of chase at bedroom 2 - Complete vent ductwork bathroom 2 - Provide roof boots - Land electrical wiring hanging in second floor hallway - Fb top plate at double wall primary bathroom shower - Complete vents ductwork at both vents at primary bathroom k - Protect DWV at primary bathroom toilet with boca plate - Protect DWV at primary bathroom vanity sill plate with boca plate
Driveway Inspection Partial 11/15/2024 11/15/2024 11/15/2024
Misc
Informational
11/15/2024
11-15-24 Dustin A, DW and curb are formed and compacted. Approved to pour
Sidewalk Inspection Partial 11/15/2024 11/15/2024 11/15/2024
Misc
Informational
11/15/2024
11-15-24 Dustin A, SW has been formed and compacted and slopes are in compliance. Approved to pour
Driveway Inspection Passed 11/22/2024 11/22/2024 11/22/2024
Misc
Informational
11/15/2024
11-15-24 Dustin A, DW and curb are formed and compacted. Approved to pour 11-15-24 Dustin A, DW is poured to city specs. Slopes are in compliance. Pass
Sidewalk Inspection Failed 11/22/2024 11/22/2024 11/22/2024
Misc
Informational
11/15/2024
11-15-24 Dustin A, SW has been formed and compacted and slopes are in compliance. Approved to pour 11-22-24 Dustin A, SW has been poured. Slopes are in compliance . One side is missing expansion joint. Failed
Occupancy Inspection - Codes Residential Not Ready 12/3/2024 12/3/2024 12/03/2024
Misc
Corrective Action Required
12/03/2024
Inspection denied no erosion control
Erosion Control Inspection Residential Failed 12/3/2024 12/3/2024 12/03/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
12/03/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED RE- ESTABLIST EROSION CONTROL AT FRONT OF LOT
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/03/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM5 ESC INSP DENIED
Corrective Action Required
12/03/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Occupancy Inspection - Codes Residential Not Ready 12/5/2024 12/5/2024 12/05/2024
Misc
Corrective Action Required
12/03/2024
Inspection denied no hand rail or guard rail at interior stairs to 2nd floor. NOT READY
Occupancy Inspection - Codes Residential Failed 12/6/2024 12/6/2024 12/06/2024
Misc
Resolved
12/06/2024
Inspection denied no hand rail or guard rail at interior stairs to 2nd floor. NOT READY
Misc
Corrective Action Required
12/06/2024
-address pending sidewalk inspection -provide as graded plot plan -uncover covered water meter pit -garage door to be self closing and latching -water hammer device for dishwasher
Occupancy Inspection - Codes Residential Ready for Temp CO 12/9/2024 12/9/2024 12/09/2024
Misc
Corrective Action Required
12/06/2024
-address pending sidewalk inspection -provide as graded plot plan -uncover covered water meter pit
Sidewalk Inspection Partial 12/9/2024 12/09/2024
Misc
Informational
11/22/2024
11-15-24 Dustin A, SW has been formed and compacted and slopes are in compliance. Approved to pour 11-22-24 Dustin A, SW has been poured. Slopes are in compliance . One side is missing expansion joint. Failed 12-9-24 Dustin A, Sw panel is reformed and compacted to city specs. Approved to pour
Sidewalk Inspection Passed 12/16/2024 12/16/2024 12/16/2024
Misc
Informational
12/09/2024
11-15-24 Dustin A, SW has been formed and compacted and slopes are in compliance. Approved to pour 11-22-24 Dustin A, SW has been poured. Slopes are in compliance . One side is missing expansion joint. Failed 12-9-24 Dustin A, Sw panel is reformed and compacted to city specs. Approved to pour 12-16-24 Dustin A, sw has been replaced and passed
Occupancy Inspection - Codes Residential Ready for Temp CO 1/8/2025 01/08/2025
Misc
Corrective Action Required
12/09/2024
TCO extension granted for and additional 30 days. Mitchell Schwarz 01/08/2025 2:22 PM -sod - splash blocks and sump pump discharge -provide as graded plot plan -uncover covered water meter pit
Occupancy Inspection - Codes Residential Failed 3/17/2025 3/17/2025 03/17/2025
Misc
Corrective Action Required
01/08/2025
Bring water meter well lid to grade.
Documents & Images
Date Uploaded File Type Document Name
05/21/2024 Permit Codes Residential Plan Review
05/30/2024 HT #203 - PERMIT APP
06/03/2024 Approved Plans APPROVED TRUSS PACKAGE
06/06/2024 Permit Codes Residential Plan Review
06/11/2024 Approved Plans APPROVED PLANS
06/11/2024 Plot Plan APPROVED PLOT PLAN
06/11/2024 Approved Plans APPROVED TRUSS LAYOUT
06/11/2024 Permit Codes Residential Plan Review
06/13/2024 Permit DS Building Permit
06/13/2024 Receipt Receipt for transaction:2024-004723
06/20/2024 3RD Party Insp Report THIRD PARTY FOOTING INSPECTION
07/03/2024 Letter INSPECTION SUMMARY
07/03/2024 Letter INSPECTION SUMMARY
07/16/2024 Letter INSPECTION SUMMARY
07/16/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter INSPECTION SUMMARY
08/20/2024 Letter INSPECTION SUMMARY
08/20/2024 Letter INSPECTION SUMMARY
09/30/2024 Letter INSPECTION SUMMARY
09/30/2024 Letter INSPECTION SUMMARY
09/30/2024 Letter INSPECTION SUMMARY
09/30/2024 Letter INSPECTION SUMMARY
09/30/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/07/2024 3RD Party Insp Report 203 Hawthorn Ridge Field Issue- signed
10/07/2024 Letter INSPECTION SUMMARY
11/15/2024 Letter INSPECTION SUMMARY
11/15/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter INSPECTION SUMMARY
12/04/2024 Receipt Receipt for transaction:2024-009316
12/05/2024 Letter INSPECTION SUMMARY
12/06/2024 Letter INSPECTION SUMMARY
12/09/2024 Letter INSPECTION SUMMARY
12/09/2024 Letter INSPECTION SUMMARY
12/09/2024 Certificate/License Codes Temporary Certificate of Occupancy
12/09/2024 Receipt Receipt for transaction:2024-009395
12/13/2024 Plot Plan APPROVED AS BUILT PLOT PLAN
12/16/2024 Letter INSPECTION SUMMARY
12/16/2024 Letter INSPECTION SUMMARY
01/08/2025 Application Form HT #203 - TCO Extension 1_8_25
03/13/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/13/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/13/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/13/2025 Receipt Receipt for transaction:2025-001543
03/17/2025 Letter INSPECTION SUMMARY
03/17/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home