Permit Application Status

PRRES20242212


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20242212
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. WALKOUT BASEMENT. COVERED DECK. ENGINEERED FLOOR SYSTEM - DEFERRED.
05/02/2024
05/17/2024
11/05/2024
07/02/2025
Locations
Contacts
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST, Phone:(816) 470-0074  
Erin Skinner, Address:1314 SW Market Street  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
JORDAN@JFECONSTRUCTION.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,760.00 $3,760.00 Paid 05/17/2024
Water Meter Fee $680.46 $680.46 Paid 05/17/2024
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 05/17/2024
Right of Way Permit Fee $85.00 $85.00 Paid 05/17/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 05/17/2024
Valuation Fee New Single Family $1,901.72 $1,901.72 Paid 05/17/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 12/05/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 06/20/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/22/2024 10/22/2024 10/22/2024
Misc
Informational
10/22/2024
Footing approved by Al Hermans on 10/8/24
Erosion Control Inspection Residential Partial 10/22/2024 10/22/2024 10/22/2024
Misc
Informational
10/22/2024
In compliance at time of inspection
Erosion Control Inspection Residential Partial 10/31/2024 10/31/2024
Misc
Informational
10/22/2024
In compliance at time of inspection
Sewer Service Inspection - R Passed 10/31/2024 10/31/2024 10/31/2024
Water Service Inspection - R Passed 11/1/2024 11/1/2024 11/01/2024
Erosion Control Inspection Residential Failed 11/1/2024 11/1/2024 11/01/2024
Misc
Corrective Action Required
11/01/2024
Restore erosion control methods and clean debris from street
Underslab Electrical Inspection - Residential Passed 11/12/2024 11/12/2024 11/12/2024
Underslab Plumbing Inspection - Residential Passed 11/12/2024 11/12/2024 11/12/2024
Erosion Control Inspection Residential Partial 11/12/2024 11/12/2024 11/12/2024
Misc
Resolved
11/12/2024
Restore erosion control methods and clean debris from street
All Rough Inspection - Residential Not Ready 12/2/2024 12/2/2024 12/02/2024
Misc
Corrective Action Required
12/02/2024
Inspection denide- Not Ready - still building, hold down straps are not nailed, no nail patern, did not go in.
All Rough Inspection - Residential Failed 12/10/2024 12/10/2024 12/10/2024
Misc
Informational
12/10/2024
Garage PFH and back CSPF exterior only ok to cover
Electrical Service Inspection Passed 2/26/2025 2/26/2025 02/26/2025
Gas Service Inspection - Residential Failed 2/26/2025 2/26/2025 02/26/2025
Miscellaneous Correction
Corrective Action Required
02/26/2025
No pressure gauge on system at the time of inspection
All Rough Inspection - Residential Failed 2/26/2025 2/26/2025 02/26/2025
Misc
Resolved
02/26/2025
Garage PFH and back CSPF exterior only ok to cover
Miscellaneous Correction
Corrective Action Required
02/26/2025
-Small garage overhead door header does not extend all the way to to king stud on the south side -Nail plate is needed in master bathroom to laundry room at hot water pipe -HVAC duct support bracket in basement family room is broken -Joist bracket for I joist in closet 4 is missing -BOCA plate is required for protection in top plate of bedroom 4 to bar area at water and DWV lines -No gas pressure gauge on system at the time of inspection
Gas Service Inspection - Residential Passed 2/27/2025 2/27/2025 02/27/2025
Miscellaneous Correction
Resolved
02/27/2025
No pressure gauge on system at the time of inspection
Erosion Control Inspection Residential Partial 3/3/2025 03/03/2025
Misc
Corrective Action Required
03/03/2025
- Erosion control in place at time of inspection.
All Rough Inspection - Residential Passed 3/3/2025 3/3/2025 03/03/2025
Miscellaneous Correction
Resolved
03/03/2025
Driveway Inspection Partial 5/23/2025 5/23/2025 05/23/2025
Misc
Informational
05/23/2025
05/23/25 Friday JMJ (Concrete Design of KC, Inc.) Driveway passed pre-inspection of forms and materials.
Sidewalk Inspection Partial 5/23/2025 5/23/2025 05/23/2025
Misc
Informational
05/23/2025
05/23/25 Friday JMJ (Concrete Design of KC, Inc.) Sidewalk- forms and materials passed pre-inspection.
Driveway Inspection Passed 5/27/2025 5/27/2025 05/27/2025
Misc
Informational
05/23/2025
05/23/25 Friday JMJ (Concrete Design of KC, Inc.) Driveway passed pre-inspection of forms and materials. 05/27/25 Tuesday JMJ (Concrete Design of KC, Inc.) Driveway passed.
Sidewalk Inspection Passed 5/27/2025 5/27/2025 05/27/2025
Misc
Informational
05/23/2025
05/23/25 Friday JMJ (Concrete Design of KC, Inc.) Sidewalk- forms and materials passed pre-inspection. 05/27/25 Tuesday JMJ (Concrete Design of KC, Inc.) Sidewalk passed final inspection.
Occupancy Inspection - Codes Residential Failed 6/17/2025 6/17/2025 06/17/2025
Misc
Corrective Action Required
06/17/2025
-provide as graded plot plan -provide issued lawn irrigation permit -garage door to be self closing and LATCHING -remove all smoke detector dust covers for inspection/testing -all outlets under sink to be GFCI protected -secondary locking device required at rear slider -uncover covered water meter
Occupancy Inspection - Codes Residential Failed 6/17/2025 6/17/2025 06/17/2025
Misc
Corrective Action Required
06/17/2025
-provide as graded plot plan -provide issued lawn irrigation permit -sod -splash blocks and sump pump discharge to extend 36” from foundation -garage door to be self closing and LATCHING -remove all smoke detector dust covers for inspection/testing -all outlets under sink to be GFCI protected -secondary locking device required at rear slider -uncover covered water meter
Occupancy Inspection - Codes Residential Ready for Temp CO 6/20/2025 6/20/2025 06/20/2025
Misc
Corrective Action Required
06/17/2025
-provide as graded plot plan -provide issued lawn irrigation permit -sod -splash blocks and sump pump discharge to extend 36” from foundation
Erosion Control Inspection Residential Partial 06/20/2025
Misc
Corrective Action Required
03/03/2025
- Erosion control in place at time of inspection.
Plot Plan Inspection Passed 6/25/2025 06/25/2025
Erosion Control Inspection Residential Passed 07/02/2025
Misc
Resolved
07/02/2025
- Erosion control in place at time of inspection.
Occupancy Inspection - Codes Residential Full C of O 7/2/2025 7/2/2025 07/02/2025
Misc
Resolved
07/02/2025
-provide as graded plot plan -provide issued lawn irrigation permit -sod -splash blocks and sump pump discharge to extend 36” from foundation
Documents & Images
Date Uploaded File Type Document Name
05/02/2024 WR158 - Permit App
05/02/2024 WR158 - Tax App
05/09/2024 Permit Codes Residential Plan Review
05/16/2024 Approved Plans APPROVED PLANS
05/16/2024 Plot Plan APPROVED PLOT PLAN
05/16/2024 Permit Codes Residential Plan Review
05/17/2024 Permit DS Building Permit
05/17/2024 Receipt Receipt for transaction:2024-003599
09/27/2024 Approved Plans APPROVED PIER PLAN
10/04/2024 Letter Codes 140 Day Letter
10/08/2024 3RD Party Insp Report 373 NW Patch Ct_PIER INSP_2024-10-07
10/21/2024 373 NW PATCH CT FTG INSP
10/22/2024 Letter INSPECTION SUMMARY
10/22/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
11/20/2024 373 NW Patch Ct_ALL SLAB INSP_2024-11-14
11/21/2024 Approved Plans APPROVED JOIST DRAWING
12/02/2024 Letter INSPECTION SUMMARY
12/05/2024 Receipt Receipt for transaction:2024-009355
12/10/2024 Letter INSPECTION SUMMARY
02/12/2025 Approved Plans 2-12-25 APPROVED PLANS
02/26/2025 Letter INSPECTION SUMMARY
02/26/2025 Letter INSPECTION SUMMARY
02/26/2025 Letter INSPECTION SUMMARY
02/27/2025 Letter INSPECTION SUMMARY
03/03/2025 373 NW Patch Ct__Framing Evaluation Report_3-3-25
03/03/2025 Letter INSPECTION SUMMARY
03/03/2025 Letter INSPECTION SUMMARY
03/03/2025 Letter INSPECTION SUMMARY
05/23/2025 Letter INSPECTION SUMMARY
05/23/2025 Letter INSPECTION SUMMARY
05/23/2025 Letter INSPECTION SUMMARY
05/27/2025 Letter INSPECTION SUMMARY
05/27/2025 Letter INSPECTION SUMMARY
06/17/2025 Letter INSPECTION SUMMARY
06/17/2025 Letter INSPECTION SUMMARY
06/20/2025 Letter INSPECTION SUMMARY
06/20/2025 Letter INSPECTION SUMMARY
06/20/2025 Certificate/License Codes Temporary Certificate of Occupancy
06/20/2025 Receipt Receipt for transaction:2025-004694
06/24/2025 Plot Plan APPROVED AS GRADED PLOT PLAN
06/25/2025 Letter INSPECTION SUMMARY
07/02/2025 Letter INSPECTION SUMMARY
07/02/2025 Letter Codes Final Certificate of Occupancy
07/02/2025 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home