Permit Application Status

PRRES20242186


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20242186
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. COVERED PATIO. ROOF TRUSSES. STOP WORK ORDER generated on 07/08/2024 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 07/31/2024 12:00 AM by username 'Shawn Hoffman'.
05/01/2024
05/13/2024
11/03/2024
01/02/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
TYLER@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,760.00 $3,760.00 Paid 05/13/2024
Water Meter Fee $680.46 $680.46 Paid 05/13/2024
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 05/13/2024
Right of Way Permit Fee $85.00 $85.00 Paid 05/13/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 05/13/2024
Valuation Fee New Single Family $1,530.52 $1,530.52 Paid 05/13/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 11/26/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 11/26/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 11/26/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/5/2024 06/05/2024
Sewer Service Inspection - R Failed 6/5/2024 06/05/2024
Misc
Corrective Action Required
06/05/2024
Clean out required every 100’
Sewer Service Inspection - R Passed 6/5/2024 6/5/2024 06/05/2024
Misc
Resolved
06/05/2024
Clean out required every 100’
Underslab Plumbing Inspection - Residential Passed 6/21/2024 6/21/2024 06/21/2024
Water Service Inspection - R Passed 7/2/2024 07/02/2024
Erosion Control Inspection Residential Failed 7/2/2024 7/2/2024 07/02/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/02/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Clean street Maintain down silt fence
Erosion Control Inspection Residential Failed - Stop Work 7/8/2024 7/8/2024 07/08/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/02/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Clean street Maintain down silt fence Still not in compliance 07/08/24
Erosion Control Inspection Residential Failed 7/25/2024 07/25/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/08/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Clean street Maintain down silt fence Still not in compliance 07/08/24
Misc
Corrective Action Required
07/25/2024
07/25/24- contain trash and debris on lot
Erosion Control Inspection Residential Partial 7/31/2024 07/31/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
07/31/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Clean street Maintain down silt fence Still not in compliance 07/08/24
Misc
Resolved
07/31/2024
07/25/24- contain trash and debris on lot
Misc
Corrective Action Required
07/31/2024
- EROSION CONTROL IN COMPLIANCE AT TIME OF INSPECTION
Piers/Caissons Inspection - Residential Passed 8/5/2024 8/5/2024 08/05/2024
Erosion Control Inspection Residential Partial 8/5/2024 08/05/2024
Misc
Corrective Action Required
07/31/2024
- EROSION CONTROL IN COMPLIANCE AT TIME OF INSPECTION
Electrical Service Inspection Passed 9/9/2024 9/9/2024 09/09/2024
Gas Service Inspection - Residential Failed 9/9/2024 9/9/2024 09/09/2024
Misc
Corrective Action Required
09/09/2024
Pressure gauge not working correctly
G2417.4.1 Test Pressure
Corrective Action Required
09/09/2024
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
All Rough Inspection - Residential Failed 9/9/2024 9/9/2024 09/09/2024
Misc
Corrective Action Required
09/09/2024
-furr out garage wall for insulation and fireblock top -nail GT truss above double car bay together to plans -all anchor bolts to be securely fastened -lib bracing not installed to plans (missing in some areas, missing nails, cut, incorrect size) -address broken truss B10 -uncover covered rear patio and front porch framing -missing lateral bracing on multiple trusses throughout -solid block between joists above beam in basement -address holes drilled to close to one another in joist at beam end E side of basement
All Rough Inspection - Residential Failed 9/19/2024 9/19/2024 09/19/2024
Misc
Corrective Action Required
09/09/2024
-lib bracing not installed to plans (missing in some areas, missing nails, cut, incorrect size)[above stairs] -address broken truss B10 -uncover covered rear patio and front porch framing
All Rough Inspection - Residential Not Ready 9/20/2024 9/20/2024 09/20/2024
Misc
Corrective Action Required
09/19/2024
-lib bracing not installed to plans (missing in some areas, missing nails, cut, incorrect size)[above stairs] -address broken truss B10 -uncover covered rear patio and front porch framing
All Rough Inspection - Residential Failed 9/25/2024 9/25/2024 09/25/2024
Misc
Corrective Action Required
09/20/2024
-address broken truss B10 leave open
All Rough Inspection - Residential Failed 10/7/2024 10/7/2024 10/07/2024
Misc
Corrective Action Required
09/25/2024
-address broken truss B10 leave open Can not confirm fix is to engineer specifications. Can not see nailing and length of added 2x
Driveway Inspection Partial 10/24/2024 10/24/2024 10/24/2024
Misc
Informational
10/24/2024
10-24-24 Dustin A, DW is formed and aggregate is compacted. Approved to pour.
Driveway Inspection Passed 10/31/2024 10/31/2024 10/30/2024
Misc
Informational
10/24/2024
10-24-24 Dustin A, DW is formed and aggregate is compacted. Approved to pour. 10-30-24 Dustin A, DW is poured to city specs.. Passed
Gas Service Inspection - Residential Passed 11/1/2024 11/1/2024 11/01/2024
Misc
Resolved
11/01/2024
Pressure gauge not working correctly
G2417.4.1 Test Pressure
Resolved
11/01/2024
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
All Rough Inspection - Residential Passed 11/20/2024 11/20/2024 11/20/2024
Misc
Resolved
11/20/2024
-address broken truss B10 leave open Can not confirm fix is to engineer specifications. Can not see nailing and length of added 2x
Plot Plan Inspection Passed 11/22/2024 11/22/2024
Erosion Control Inspection Residential Partial 11/22/2024 11/22/2024
Misc
Corrective Action Required
08/05/2024
- EROSION CONTROL IN COMPLIANCE AT TIME OF INSPECTION
Occupancy Inspection - Codes Residential Not Ready 11/22/2024 11/22/2024 11/22/2024
Misc
Corrective Action Required
11/22/2024
NOT READY NO INSPECTION FIREPLACE NOT INSTALLED ELECTRICIANS STILL WORKING OPEN OUTLETS IN KITCHEN
Occupancy Inspection - Codes Residential Failed 11/25/2024 11/25/2024 11/25/2024
Misc
Resolved
11/25/2024
NOT READY NO INSPECTION FIREPLACE NOT INSTALLED ELECTRICIANS STILL WORKING OPEN OUTLETS IN KITCHEN
Miscellaneous Correction
Corrective Action Required
11/25/2024
Fireplace is not installed Seal hole in garage ceiling sheet rock Secure garage overhead door track within 18 inches of floor Sod and splash pads are not installed Seal exterior penetrations
Occupancy Inspection - Codes Residential Failed 11/25/2024 11/25/2024
Miscellaneous Correction
Corrective Action Required
11/25/2024
Fireplace is not installed Seal hole in garage ceiling sheet rock Secure garage overhead door track within 18 inches of floor Sod and splash pads are not installed Seal exterior penetrations Pay $150 in fees associated with this permit
Occupancy Inspection - Codes Residential Ready for Temp CO 11/26/2024 11/26/2024 11/26/2024
Miscellaneous Correction
Resolved
11/26/2024
Fireplace is not installed Seal hole in garage ceiling sheet rock Secure garage overhead door track within 18 inches of floor Sod and splash pads are not installed Seal exterior penetrations Pay $150 in fees associated with this permit
Miscellaneous Correction
Corrective Action Required
11/26/2024
Sod and splash pads are not installed Pay $150 in fees associated with this permit Passed for TCO only
Erosion Control Inspection Residential Passed 01/02/2025
Misc
Resolved
01/02/2025
- EROSION CONTROL IN COMPLIANCE AT TIME OF INSPECTION
Occupancy Inspection - Codes Residential Full C of O 1/2/2025 01/02/2025
Miscellaneous Correction
Resolved
01/02/2025
Sod and splash pads are not installed Pay $150 in fees associated with this permit Passed for TCO only
Documents & Images
Date Uploaded File Type Document Name
05/07/2024 H4 #120 - PERMIT APP
05/07/2024 Permit Codes Residential Plan Review
05/07/2024 Approved Plans APPROVED PLANS
05/13/2024 Plot Plan APPROVED PLOT PLAN
05/13/2024 Approved Plans APPROVED TRUSS LAYOUT
05/13/2024 Approved Plans APPROVED TRUSS PACKAGE
05/13/2024 Permit Codes Residential Plan Review
05/13/2024 Permit DS Building Permit
05/13/2024 Receipt Receipt for transaction:2024-003294
05/22/2024 3RD Party Insp Report THIRD PARTY FOOTING INSPECTION
06/05/2024 Letter INSPECTION SUMMARY
06/05/2024 Letter INSPECTION SUMMARY
06/05/2024 Letter INSPECTION SUMMARY
06/21/2024 Letter INSPECTION SUMMARY
07/02/2024 Letter INSPECTION SUMMARY
07/02/2024 Letter INSPECTION SUMMARY
07/08/2024 Letter Stop Work Order
07/25/2024 Letter INSPECTION SUMMARY
08/05/2024 Letter INSPECTION SUMMARY
08/05/2024 Letter INSPECTION SUMMARY
08/05/2024 Letter INSPECTION SUMMARY
09/09/2024 Letter INSPECTION SUMMARY
09/09/2024 Letter INSPECTION SUMMARY
09/09/2024 Letter INSPECTION SUMMARY
09/19/2024 Letter INSPECTION SUMMARY
09/20/2024 Letter INSPECTION SUMMARY
09/25/2024 Letter INSPECTION SUMMARY
09/25/2024 Letter INSPECTION SUMMARY
09/30/2024 Plans 240127 B8 Repair
10/07/2024 Letter INSPECTION SUMMARY
10/24/2024 Letter INSPECTION SUMMARY
10/30/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/20/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
11/25/2024 Letter INSPECTION SUMMARY
11/25/2024 Letter INSPECTION SUMMARY
11/25/2024 Letter INSPECTION SUMMARY
11/26/2024 Letter INSPECTION SUMMARY
11/26/2024 Certificate/License Codes Temporary Certificate of Occupancy
11/26/2024 Receipt Receipt for transaction:2024-009173
01/02/2025 Letter INSPECTION SUMMARY
01/02/2025 Letter Field Certificate of Occupancy
01/02/2025 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home