Permit Application Status

PRRES20241854


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20241854
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. ROOF TRUSSES. UNCOVERED DECK.
04/15/2024
04/23/2024
12/18/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
United Heating & Cooling, Address:301 Duck Rd, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
TAYLOR@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,760.00 $3,760.00 Paid 04/23/2024
Water Meter Fee $680.46 $680.46 Paid 04/23/2024
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 04/23/2024
Right of Way Permit Fee $85.00 $85.00 Paid 04/23/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 04/23/2024
Valuation Fee New Single Family $1,735.34 $1,735.34 Paid 04/23/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 12/04/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 12/04/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Partial 5/2/2024 05/02/2024
Miscellaneous Correction
Informational
05/02/2024
Erosion control is in place and must be maintained until CofO
Footing Inspection - Residential Passed 5/2/2024 05/02/2024
Miscellaneous Correction
Informational
05/02/2024
Footing inspection was passed by a third party. Exterior piers were not mentioned in the footing report
Sewer Service Inspection - R Passed 5/16/2024 05/16/2024
Water Service Inspection - R Passed 5/17/2024 05/17/2024
Underslab Plumbing Inspection - Residential Failed 5/22/2024 5/22/2024 05/22/2024
Miscellaneous Correction
Corrective Action Required
05/22/2024
Remove all wood decaying material from foundation
Erosion Control Inspection Residential Partial 5/22/2024 05/22/2024
Miscellaneous Correction
Informational
05/02/2024
Erosion control is in place and must be maintained until CofO
Underslab Plumbing Inspection - Residential Passed 5/23/2024 5/23/2024 05/23/2024
Miscellaneous Correction
Resolved
05/23/2024
Remove all wood decaying material from foundation
All Rough Inspection - Residential Failed 6/25/2024 6/25/2024 06/25/2024
Miscellaneous Correction
Corrective Action Required
06/25/2024
-Nail exterior garage sheeting to code along the top plate This is a garage exterior portal inspection only
Erosion Control Inspection Residential Failed 7/15/2024 07/15/2024
Miscellaneous Correction
Resolved
07/15/2024
Erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
07/15/2024
Repair or replace damaged straw waddles at the front of the lot at the street Full erosion control measures must be maintained until CofO
All Rough Inspection - Residential Failed 7/25/2024 7/25/2024 07/25/2024
Miscellaneous Correction
Corrective Action Required
06/25/2024
-Nail exterior garage sheeting to code along the top plate This is a garage exterior portal inspection only
Miscellaneous Correction
Corrective Action Required
07/25/2024
3820 SW Ravengate. All rough Truss hangers are missing in garage to bedroom above Horizontal fire blocking is needed in powder bathroom furr down Nail exterior pantry corner to code Fire block to of chase in pantry Re do joist hanger above dining room 4 over from the west wall (not properly installed) Fire block top of chase in great room Plans call for (3) 2x6’s in office for stud pack bearing the load of (3) 2x10 joist above Fire block hole next to vent in ceiling above office Roof boot jackets are missing at plumbing through the roof Nail exterior corner of bedroom 2 to code Plumbing nail guard is needed in bedroom 3 to bathroom 2 in two locations Truss tie down screw is missing in primary bedroom N/E corner 1 LGT2 located in primary bedroom to linen is not installed HDU14-SDS2.5 is not installed in main to basement stairwell exterior corner Fire blocking is missing in one joist bay above basement I beam 3 over from west wall One joist hanger above basement window is not installed Nail garage exterior sheeting to both top plates
Gas Service Inspection - Residential Passed 7/25/2024 07/25/2024
Electrical Service Inspection Passed 7/25/2024 07/25/2024
All Rough Inspection - Residential Failed 8/2/2024 8/2/2024 08/02/2024
Miscellaneous Correction
Corrective Action Required
07/25/2024
-Nail exterior garage sheeting to code along the top plate This is a garage exterior portal inspection only
Miscellaneous Correction
Partial Correction
08/02/2024
Nail garage exterior sheeting to both top plates
All Rough Inspection - Residential Passed 8/6/2024 8/6/2024 08/06/2024
Miscellaneous Correction
Resolved
08/06/2024
Miscellaneous Correction
Resolved
08/06/2024
Erosion Control Inspection Residential Partial 8/13/2024 08/13/2024
Miscellaneous Correction
Resolved
08/13/2024
Repair or replace damaged straw waddles at the front of the lot at the street Full erosion control measures must be maintained until CofO
Miscellaneous Correction
Informational
08/13/2024
Full erosion control measures are in place and must be maintained until CofO
Driveway Inspection Partial 8/14/2024 08/14/2024
Misc
Informational
08/14/2024
8-14-24 Dustin A, Dw is formed and compacted to city specs. Must maintain ADA compliance throughout approach. Approved to pour
Sidewalk Inspection Partial 8/14/2024 08/14/2024
Misc
Informational
08/14/2024
8-14-24 Dustin A, SW is formed and compacted to city specs. Slopes are in compliance. Approved to pour
Driveway Inspection Passed 8/23/2024 8/23/2024 08/23/2024
Misc
Informational
08/14/2024
8-14-24 Dustin A, Dw is formed and compacted to city specs. Must maintain ADA compliance throughout approach. Approved to pour 8-23-24 DP. DW was poured, cross slopes in compliance, forms removed. Passed.
Sidewalk Inspection Passed 8/23/2024 8/23/2024 08/23/2024
Misc
Informational
08/14/2024
8-14-24 Dustin A, SW is formed and compacted to city specs. Slopes are in compliance. Approved to pour 8-23-24 DP. SW was poured, cross slopes are in compliance and forms have been removed. Passed
Occupancy Inspection - Codes Residential Failed 9/26/2024 9/26/2024 09/26/2024
Miscellaneous Correction
Corrective Action Required
09/26/2024
Front driveway lights are not installed Inspection denied and is not ready Scrape mud from sidewalk before rescheduling inspection This is not a complete list
Corrective Action Required
09/26/2024
Occupancy Inspection - Codes Residential Not Ready 10/1/2024 10/1/2024 10/01/2024
Miscellaneous Correction
Resolved
10/01/2024
Front driveway lights are not installed Inspection denied and is not ready Scrape mud from sidewalk before rescheduling inspection This is not a complete list
Miscellaneous Correction
Corrective Action Required
10/01/2024
No access Front and back door was locked Not ready
Erosion Control Inspection Residential Partial 10/2/2024 10/02/2024
Miscellaneous Correction
Informational
08/13/2024
Full erosion control measures are in place and must be maintained until CofO
Plot Plan Inspection Failed 10/2/2024 10/02/2024
Miscellaneous Correction
Corrective Action Required
10/02/2024
Plot plans shows ADA ramp which is not installed.
Occupancy Inspection - Codes Residential Failed 10/2/2024 10/2/2024 10/02/2024
Miscellaneous Correction
Resolved
10/02/2024
No access Front and back door was locked Not ready
Miscellaneous Correction
Corrective Action Required
10/02/2024
3820 SW Ravengate Occupancy Install guard rails on stairs in garage to house. Code requires guard rails to be installed on steps of 4 or more. The threshold counts as a step First riser from the main living area to the basement is over the code allowance of 7 3/4 inches in height Last step going to the basement at the platform does not have the code 36 inches of travel distance A couple of 12/2 wire in basement needs to be vertically supported to code A couple of 14/2 wire in basement needs to be vertically supported to code Hot water heater needs a lock out installed at the panel Electrical receptacle by basement HVAC needs to state it is non GFCI protected Seal front driveway lights Seal penetrations in exterior siding Sod and splash pads are not installed Ada ramp is not installed as per plans Pay $75 fee associated with this permit
Sidewalk Inspection Partial 10/3/2024 10/3/2024 10/03/2024
Misc
Informational
10/03/2024
10-3-24 DP. Crew had formed the missed ADA ramp on the development. Running slopes were able to be in compliance. The cross slopes will be slightly above 3% at the existing sidewalk. Every thought was exhausted and the ADA ramp is being poured as well as it can get. Approved to pour
Erosion Control Inspection Residential Partial 10/4/2024 10/04/2024
Miscellaneous Correction
Informational
10/02/2024
Full erosion control measures are in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Ready for Temp CO 10/4/2024 10/4/2024 10/04/2024
Miscellaneous Correction
Resolved
10/04/2024
3820 SW Ravengate Occupancy Install guard rails on stairs in garage to house. Code requires guard rails to be installed on steps of 4 or more. The threshold counts as a step First riser from the main living area to the basement is over the code allowance of 7 3/4 inches in height Last step going to the basement at the platform does not have the code 36 inches of travel distance A couple of 12/2 wire in basement needs to be vertically supported to code A couple of 14/2 wire in basement needs to be vertically supported to code Hot water heater needs a lock out installed at the panel Electrical receptacle by basement HVAC needs to state it is non GFCI protected Seal front driveway lights Seal penetrations in exterior siding Sod and splash pads are not installed Ada ramp is not installed as per plans Pay $75 fee associated with this permit
Miscellaneous Correction
Corrective Action Required
10/04/2024
Sod and splash pads are not installed Pay $75 fee associated with permit Passed for TCO only
Sidewalk Inspection Passed 10/4/2024 10/4/2024 10/04/2024
Misc
Informational
10/03/2024
10-3-24 DP. Crew had formed the missed ADA ramp on the development. Running slopes were able to be in compliance. The cross slopes will be slightly above 3% at the existing sidewalk. Every thought was exhausted and the ADA ramp is being poured as well as it can get. Approved to pour 10-4-24 DP. ADA ramp was poured, forms have been removed. Still Need to remove plastic from indicator pad. Passed.
Erosion Control Inspection Residential Failed 11/1/2024 11/01/2024
Miscellaneous Correction
Resolved
11/01/2024
Full erosion control measures are in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
11/01/2024
Repair or replace damaged straw waddle along north side of property Full erosion control measures must be in place and properly maintained until CofO
Erosion Control Inspection Residential Failed 11/4/2024 11/4/2024 11/04/2024
Miscellaneous Correction
Corrective Action Required
11/01/2024
Repair or replace damaged straw waddle along north side of property Full erosion control measures must be in place and properly maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/04/2024
11-4-24 Dustin A, Silt has washed out on sw. Needs cleaned up. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Plot Plan Inspection Passed 12/5/2024 12/05/2024
Miscellaneous Correction
Resolved
12/05/2024
Plot plans shows ADA ramp which is not installed.
Erosion Control Inspection Residential Passed 12/5/2024 12/05/2024
Miscellaneous Correction
Resolved
12/05/2024
Repair or replace damaged straw waddle along north side of property Full erosion control measures must be in place and properly maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Resolved
12/05/2024
11-4-24 Dustin A, Silt has washed out on sw. Needs cleaned up. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Full C of O 12/18/2024 12/18/2024 12/18/2024
Miscellaneous Correction
Resolved
12/18/2024
Sod and splash pads are not installed Pay $75 fee associated with permit Passed for TCO only
Documents & Images
Date Uploaded File Type Document Name
04/15/2024 OS #64 - ENGINEERED PLANS
04/15/2024 OS #64 - Permit App
04/15/2024 OS #64 - PLOT PLAN
04/15/2024 OS #64 - TRUSS DETAILS
04/15/2024 OS #64 - TRUSS LAYOUT
04/19/2024 Plot Plan APPROVED PLOT PLAN
04/19/2024 Approved Plans APPROVED TRUSS LAYOUT
04/19/2024 Approved Plans APPROVED TRUSS PACKAGE
04/19/2024 Approved Plans APPROVED PLANS
04/19/2024 Permit Codes Residential Plan Review
04/23/2024 Permit DS Building Permit
04/23/2024 Receipt Receipt for transaction:2024-002584
05/01/2024 3RD Party Insp Report THIRD PARTY FOOTING INSPECTION
05/02/2024 Letter INSPECTION SUMMARY
05/02/2024 Letter INSPECTION SUMMARY
05/16/2024 Letter INSPECTION SUMMARY
05/17/2024 Letter INSPECTION SUMMARY
05/22/2024 Letter INSPECTION SUMMARY
05/22/2024 Letter INSPECTION SUMMARY
05/23/2024 Letter INSPECTION SUMMARY
06/25/2024 Letter INSPECTION SUMMARY
07/15/2024 Letter INSPECTION SUMMARY
07/25/2024 Letter INSPECTION SUMMARY
07/25/2024 Letter INSPECTION SUMMARY
07/25/2024 Letter INSPECTION SUMMARY
07/25/2024 Letter INSPECTION SUMMARY
08/02/2024 Letter INSPECTION SUMMARY
08/05/2024 OS 63 TRUSSES
08/06/2024 Letter INSPECTION SUMMARY
08/13/2024 Letter INSPECTION SUMMARY
08/14/2024 Letter INSPECTION SUMMARY
08/14/2024 Letter INSPECTION SUMMARY
08/23/2024 Letter INSPECTION SUMMARY
08/23/2024 Letter INSPECTION SUMMARY
09/26/2024 Letter INSPECTION SUMMARY
10/01/2024 Letter INSPECTION SUMMARY
10/01/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/03/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/04/2024 Letter INSPECTION SUMMARY
11/04/2024 Letter INSPECTION SUMMARY
12/04/2024 Certificate/License Codes Temporary Certificate of Occupancy
12/04/2024 Receipt Receipt for transaction:2024-009345
12/05/2024 Letter INSPECTION SUMMARY
12/05/2024 Letter INSPECTION SUMMARY
12/18/2024 Letter Codes Final Certificate of Occupancy
12/18/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home