Summary
PRRES20241800
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. UNCOVERED PATIO. ROOF TRUSSES.
04/12/2024
04/23/2024
10/14/2024
12/05/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
TAYLOR@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,760.00 $3,760.00 Paid 04/23/2024
Water Meter Fee $680.46 $680.46 Paid 04/23/2024
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 04/23/2024
Right of Way Permit Fee $85.00 $85.00 Paid 04/23/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 04/23/2024
Valuation Fee New Single Family $1,735.34 $1,735.34 Paid 04/23/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 10/04/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 12/04/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/30/2024 04/30/2024
Miscellaneous Correction
Informational
04/30/2024
-Footing passed by a third party -Piers were not mentioned in the footing report
Erosion Control Inspection Residential Failed 4/30/2024 04/30/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/30/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Silt fence is missing or damaged -Gravel needs to be spread from the street to the foundation
Sewer Service Inspection - R Passed 5/16/2024 5/16/2024 05/16/2024
Water Service Inspection - R Passed 5/17/2024 05/17/2024
Erosion Control Inspection Residential Partial 5/22/2024 05/22/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/22/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Silt fence is missing or damaged -Gravel needs to be spread from the street to the foundation
Miscellaneous Correction
Informational
05/22/2024
Erosion control measures are in place and must be maintained until CofO
Underslab Plumbing Inspection - Residential Failed 5/22/2024 5/22/2024 05/22/2024
Miscellaneous Correction
Corrective Action Required
05/22/2024
Remove all wood decay material from foundation
Underslab Plumbing Inspection - Residential Passed 5/23/2024 5/23/2024 05/23/2024
Miscellaneous Correction
Resolved
05/23/2024
Remove all wood decay material from foundation
All Rough Inspection - Residential Failed 6/25/2024 6/25/2024 06/25/2024
Miscellaneous Correction
Informational
06/25/2024
-Exterior garage portal inspection only. -Passed and is okay to cover This is a exterior garage portal inspection only
Erosion Control Inspection Residential Failed 7/16/2024 07/16/2024
Miscellaneous Correction
Resolved
07/16/2024
Erosion control measures are in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
07/16/2024
Erosion control is damaged at the front of the lot and needs to be replaced or repaired. Full erosion control measures must be maintained until CofO
All Rough Inspection - Residential Failed 7/30/2024 7/30/2024 07/30/2024
Miscellaneous Correction
Informational
06/25/2024
-Exterior garage portal inspection only. -Passed and is okay to cover This is a exterior garage portal inspection only
Misc
Corrective Action Required
07/30/2024
-Missing fire blocking at top of chase in garage -Missing fire blocking at top of chase in pantry -NM branch wiring in pantry not landed in boxes -Nail missing at joist hanger middle of I beam south and west of kitchen island -Missing framing for hvac chase at south west corner of living room -Missing security blocking at front door -Holes drilled too close together at joists electrical -Uncover OSB at front porch area for nailing pattern inspection -Engineered bracing is not nailed or blocked per plan at stairwell area south east corner -Missing fire blocking at chase between shower and bathtub upstairs -Missing hold down device at southeast corner of stairs going to base -Over-bored hole for DWV at joist in basement south of furnace -Strap top plate above garage door minimum lag of 24 inches north east corner -Missing hold downs at truss in garage
All Rough Inspection - Residential Failed 8/7/2024 8/7/2024 08/07/2024
Miscellaneous Correction
Informational
07/30/2024
-Exterior garage portal inspection only. -Passed and is okay to cover This is a exterior garage portal inspection only
Misc
Partial Correction
08/07/2024
-Missing fire blocking at top of chase in garage (still missing around DWV) -NM branch wiring in pantry not landed in boxes (done but now hole at top plate missing fire blocking) -Missing security blocking at front door (still missing at lowest hinge) -Engineered bracing is not nailed or blocked per plan at stairwell area south east corner (still missing on east wall) -Missing hold down device at southeast corner of stairs going to base (installed but nut is not tightened down)
All Rough Inspection - Residential Passed 8/9/2024 8/9/2024 08/09/2024
Miscellaneous Correction
Informational
08/07/2024
-Exterior garage portal inspection only. -Passed and is okay to cover This is a exterior garage portal inspection only
Misc
Resolved
08/09/2024
Erosion Control Inspection Residential Partial 8/13/2024 08/13/2024
Miscellaneous Correction
Resolved
08/13/2024
Erosion control is damaged at the front of the lot and needs to be replaced or repaired. Full erosion control measures must be maintained until CofO
Miscellaneous Correction
Informational
08/13/2024
Full erosion control measures are in place and must be maintained until CofO
Driveway Inspection Partial 8/19/2024 08/19/2024
Misc
Informational
08/19/2024
8-19-24 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour
Sidewalk Inspection Partial 8/19/2024 08/19/2024
Misc
Informational
08/19/2024
8-19-24 PS Sidewalk pre pour, forms in place and aggregate compacted, approved to pour
Driveway Inspection Passed 8/28/2024 8/28/2024 08/28/2024
Misc
Informational
08/19/2024
8-19-24 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour 8-28-24 PS Approach meets ADA and LS requirements
Sidewalk Inspection Passed 8/28/2024 8/28/2024 08/28/2024
Misc
Informational
08/19/2024
8-19-24 PS Sidewalk pre pour, forms in place and aggregate compacted, approved to pour 8-28-24 PS Sidewalk meets LS and ADA requirements
Electrical Service Inspection Passed 9/13/2024 09/13/2024
Erosion Control Inspection Residential Failed 9/13/2024 09/13/2024
Miscellaneous Correction
Resolved
09/13/2024
Full erosion control measures are in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
09/13/2024
Erosion control waddles at the street have been damaged and or are missing. Full erosion control measures must be in place and maintained until CofO
Gas Service Inspection - Residential Failed 9/13/2024 9/13/2024 09/13/2024
Miscellaneous Correction
Corrective Action Required
09/13/2024
Gas inspection did not pass. Have pressure gauge installed and reschedule
Gas Service Inspection - Residential Passed 9/19/2024 9/19/2024 09/19/2024
Miscellaneous Correction
Resolved
09/19/2024
Gas inspection did not pass. Have pressure gauge installed and reschedule
Erosion Control Inspection Residential Failed 9/25/2024 09/25/2024
Miscellaneous Correction
Resolved
09/25/2024
Erosion control waddles at the street have been damaged and or are missing. Full erosion control measures must be in place and maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/25/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Erosion control waddles at the street have been damaged and or are missing. Full erosion control measures must be in place and maintained until CofO Clean mud off of sidewalk Clean mud from around storm drain at street
Occupancy Inspection - Codes Residential Failed 9/25/2024 9/25/2024 09/25/2024
Miscellaneous Correction
Corrective Action Required
09/25/2024
3824 SW Ravengate. Occupancy Oven anti tip bracket is not installed according to manufacturer specifications Hot water is not hooked up to the dishwasher Smoke detector in master bedroom is not working properly GFCI in basement by stairs is not working Receptacle in basement by HVAC needs to state it is non GFCI protected Sod, splash pads and sump pump passes are not installed Seal all exterior penetrations See failed erosion control about no further inspections
Occupancy Inspection - Codes Residential Failed 10/3/2024 10/3/2024 10/03/2024
Miscellaneous Correction
Corrective Action Required
09/25/2024
3824 SW Ravengate. Occupancy (2) GFCI in basement by stairs is not working (Has a open ground) Sod, splash pads and sump pump extension are not installed
Erosion Control Inspection Residential Partial 10/3/2024 10/03/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
10/03/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Erosion control waddles at the street have been damaged and or are missing. Full erosion control measures must be in place and maintained until CofO Clean mud off of sidewalk Clean mud from around storm drain at street
Miscellaneous Correction
Informational
10/03/2024
Full erosion control is in place and must be maintained until CofO
Plot Plan Inspection Failed 10/3/2024 10/03/2024
Miscellaneous Correction
Corrective Action Required
10/03/2024
As graded plot plan is needed before sodding
Occupancy Inspection - Codes Residential Not Ready 10/4/2024 10/4/2024 10/04/2024
Miscellaneous Correction
Corrective Action Required
10/03/2024
3824 SW Ravengate. Occupancy (3) GFCI in basement by stairs is not working (Has a open ground) Sod, splash pads and sump pump extension are not installed As graded plot plan is not uploaded Not ready for re inspection Pay not ready fee
Erosion Control Inspection Residential Partial 10/4/2024 10/04/2024
Miscellaneous Correction
Informational
10/03/2024
Full erosion control is in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Ready for Temp CO 10/7/2024 10/7/2024 10/07/2024
Miscellaneous Correction
Resolved
10/07/2024
3824 SW Ravengate. Occupancy (3) GFCI in basement by stairs is not working (Has a open ground) Sod, splash pads and sump pump extension are not installed As graded plot plan is not uploaded Not ready for re inspection Pay not ready fee
Miscellaneous Correction
Corrective Action Required
10/07/2024
Sod, splash pads and sump pump extension are not installed As graded plot plan is not uploaded
Plot Plan Inspection Passed 12/5/2024 12/05/2024
Miscellaneous Correction
Resolved
12/05/2024
As graded plot plan is needed before sodding
Erosion Control Inspection Residential Passed 12/5/2024 12/05/2024
Miscellaneous Correction
Resolved
12/05/2024
Full erosion control is in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Full C of O 12/5/2024 12/05/2024
Miscellaneous Correction
Resolved
12/05/2024
Sod, splash pads and sump pump extension are not installed As graded plot plan is not uploaded
Documents & Images
Date Uploaded File Type Document Name
04/12/2024 OS #65 - ENGINEERED PLANS
04/12/2024 OS #65 - PERMIT APP
04/12/2024 OS #65 - PLOT PLAN
04/12/2024 OS #65 - TRUSS DETAILS
04/12/2024 OS #65 - TRUSS LAYOUT
04/17/2024 Permit Codes Residential Plan Review
04/17/2024 OS #65 - PERMIT APP
04/18/2024 LOT 65 CITY
04/18/2024 Plot Plan APPROVED PLOT PLAN
04/18/2024 Approved Plans APPROVED PLANS
04/18/2024 Approved Plans APPROVED TRUSS PACKAGE
04/18/2024 Approved Plans APPROVED TRUSS LAYOUT
04/18/2024 Permit Codes Residential Plan Review
04/23/2024 Permit DS Building Permit
04/23/2024 Receipt Receipt for transaction:2024-002583
04/29/2024 3RD Party Insp Report THIRD PARTY INSPECTION
04/30/2024 Letter INSPECTION SUMMARY
04/30/2024 Letter INSPECTION SUMMARY
05/16/2024 Letter INSPECTION SUMMARY
05/17/2024 Letter INSPECTION SUMMARY
05/22/2024 Letter INSPECTION SUMMARY
05/22/2024 Letter INSPECTION SUMMARY
05/23/2024 Letter INSPECTION SUMMARY
06/25/2024 Letter INSPECTION SUMMARY
07/16/2024 Letter INSPECTION SUMMARY
07/30/2024 Letter INSPECTION SUMMARY
08/07/2024 Letter INSPECTION SUMMARY
08/09/2024 Letter INSPECTION SUMMARY
08/13/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/28/2024 Letter INSPECTION SUMMARY
08/28/2024 Letter INSPECTION SUMMARY
09/13/2024 Letter INSPECTION SUMMARY
09/13/2024 Letter INSPECTION SUMMARY
09/13/2024 Letter INSPECTION SUMMARY
09/19/2024 Letter INSPECTION SUMMARY
09/25/2024 Letter INSPECTION SUMMARY
09/25/2024 Letter INSPECTION SUMMARY
10/03/2024 Letter INSPECTION SUMMARY
10/03/2024 Letter INSPECTION SUMMARY
10/03/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Receipt Receipt for transaction:2024-008115
10/07/2024 Letter INSPECTION SUMMARY
12/04/2024 Certificate/License Codes Temporary Certificate of Occupancy
12/04/2024 Receipt Receipt for transaction:2024-009343
12/05/2024 Letter INSPECTION SUMMARY
12/05/2024 Letter INSPECTION SUMMARY
12/05/2024 Letter Codes Final Certificate of Occupancy
12/05/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home