Permit Application Status

PRRES20241221


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20241221
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. COVERED/UNCOVERED PATIO. ROOF TRUSSES.
03/15/2024
04/10/2024
09/16/2024
11/08/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
TYLER@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 04/10/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 04/10/2024
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 04/10/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 04/10/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 04/10/2024
9110078-Valuation Fee New Single Family $1,472.04 $1,472.04 Paid 04/10/2024
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 10/09/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 10/09/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 10/09/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 10/09/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 10/09/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 10/09/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/15/2024 04/15/2024
Sewer Service Inspection - R Passed 5/1/2024 (2:00) 5/1/2024 05/01/2024
Water Service Inspection - R Passed 5/8/2024 5/8/2024 05/08/2024
Underslab Plumbing Inspection - Residential Passed 5/14/2024 5/14/2024 05/14/2024
All Rough Inspection - Residential Partial 6/12/2024 6/12/2024 06/12/2024
Misc
Informational
06/12/2024
Garage portal frame and nail pattern inspection only
Gas Service Inspection - Residential Failed 7/23/2024 7/23/2024 07/23/2024
Misc
Corrective Action Required
07/23/2024
Complete and correct gas line installation
Electrical Service Inspection Passed 7/23/2024 7/23/2024 07/23/2024
All Rough Inspection - Residential Failed 7/23/2024 7/23/2024 07/23/2024
Misc
Resolved
07/23/2024
Garage portal frame and nail pattern inspection only
Misc
Corrective Action Required
07/23/2024
-address missing truss screws throughout -anchor bolts to be in the middle 1/3 of sill plate in garage (see S wall) -address cspf above at slider not framed to plans and code -address cspf nailing through out -identify bracing called out in plans at bed 1 toilet and fireplace -fireblock fireplace to ceiling space -complete outdoor fireplace framing -missing lib throughout -strap top plate where plate breaks occur less than 24” apart -nail C9 truss to plans -add support for furr down ceiling joist in basement -fireblock furr down ends in basement and beam ends -complete bath fan in basement bath -complete gas line installation -gas shut off valve shall comply with code section G2420 of the 2018 IRC
All Rough Inspection - Residential Failed 7/30/2024 7/30/2024 07/30/2024
Misc
Corrective Action Required
07/23/2024
-address electrical at slider and tie slider wall to rear greatroom wall together at top plate -address cspf nailing at rear dining -identify bracing called out in plans at bed 1 toilet and fireplace -fireblock fireplace to ceiling space -complete outdoor fireplace framing -missing lib throughout -strap top plate where plate breaks occur less than 24” apart -nail C9 truss to plans -fireblock furr down ends in basement and beam ends -complete gas line installation -gas shut off valve shall comply with code section G2420 of the 2018 IRC
All Rough Inspection - Residential Failed 8/1/2024 8/1/2024 08/01/2024
Misc
Corrective Action Required
07/30/2024
-identify bracing called out in plans at bed 1 toilet and fireplace -complete outdoor fireplace framing -complete gas line installation -gas shut off valve shall comply with code section G2420 of the 2018 IRC
All Rough Inspection - Residential Not Ready 8/7/2024 8/7/2024 08/07/2024
Misc
Corrective Action Required
08/01/2024
-identify bracing called out in plans at bed 1 toilet and fireplace -complete outdoor fireplace framing
Gas Service Inspection - Residential Failed 8/27/2024 8/27/2024 08/27/2024
Misc
Corrective Action Required
07/23/2024
Complete and correct gas line installation 08-27-24 No pressure at gas line for inspection
All Rough Inspection - Residential Not Ready 8/27/2024 8/27/2024 08/27/2024
Misc
Corrective Action Required
08/07/2024
-identify bracing called out in plans at bed 1 toilet and fireplace -complete outdoor fireplace framing
Driveway Inspection Partial 9/5/2024 9/5/2024 09/05/2024
Misc
Informational
09/05/2024
9-524 Dustin A, DW is formed to city specs. Approved to pour
Driveway Inspection Passed 9/12/2024 9/12/2024 09/12/2024
Misc
Informational
09/05/2024
9-524 Dustin A, DW is formed to city specs. Approved to pour 9-12-24 Dustin A, DW is poured to city specs . Passed
Gas Service Inspection - Residential Not Ready 10/3/2024 10/3/2024 10/03/2024
Misc
Corrective Action Required
08/27/2024
Complete and correct gas line installation 08-27-24 No pressure at gas line for inspection No access inspection denied. Gas line incomplete outside-10/03/24
All Rough Inspection - Residential Failed 10/4/2024 10/4/2024 10/04/2024
Misc
Corrective Action Required
08/27/2024
-identify bracing called out in plans at bed 1 toilet and fireplace( top and bottom of panels to be screwed to design behind fireplace must extend from top plate to bottom plate, bath walls not completely screwed,) -complete outdoor fireplace framing (covered without inspection)
Occupancy Inspection - Codes Residential Failed 10/4/2024 10/4/2024 10/04/2024
Misc
Corrective Action Required
10/04/2024
Complete all rough inspection before scheduling occupancy.
Gas Service Inspection - Residential Not Ready 10/4/2024 10/4/2024 10/04/2024
Misc
Corrective Action Required
10/03/2024
Complete and correct gas line installation 08-27-24 No pressure at gas line for inspection No access inspection denied. Gas line incomplete outside-10/03/24 No gauge on gas line -10/4/24
Gas Service Inspection - Residential Passed 10/7/2024 10/7/2024 10/07/2024
Misc
Resolved
10/07/2024
Complete and correct gas line installation 08-27-24 No pressure at gas line for inspection No access inspection denied. Gas line incomplete outside-10/03/24 No gauge on gas line -10/4/24
Plot Plan Inspection Passed 10/08/2024
All Rough Inspection - Residential Passed 10/8/2024 10/8/2024 10/08/2024
Misc
Resolved
10/08/2024
-identify bracing called out in plans at bed 1 toilet and fireplace( top and bottom of panels to be screwed to design behind fireplace must extend from top plate to bottom plate, bath walls not completely screwed,) -complete outdoor fireplace framing (covered without inspection)
Occupancy Inspection - Codes Residential Ready for Temp CO 10/8/2024 10/8/2024 10/08/2024
Misc
Corrective Action Required
10/04/2024
-pay all fees -splash blocks -siding from grade on S side of home not in compliance -establish vegetation in disturbed green space behind lot
Occupancy Inspection - Codes Residential Full C of O 11/8/2024 11/08/2024
Misc
Resolved
11/08/2024
-pay all fees -splash blocks -siding from grade on S side of home not in compliance -establish vegetation in disturbed green space behind lot
Documents & Images
Date Uploaded File Type Document Name
03/15/2024 HT # 172 - ENGINEERED PLANS
03/15/2024 HT # 172 - PERMIT APP
03/15/2024 HT # 172 - PLOT PLAN
03/15/2024 HT # 172 - TRUSS DETAILS
03/15/2024 HT # 172 - TRUSS LAYOUT
03/20/2024 Permit Codes Residential Plan Review
04/09/2024 HT 172 - RESPONSE TO PLAN REVIEW COMMENTS- 240409
04/09/2024 LOT 172 CITY
04/09/2024 Approved Plans APPROVED PLANS
04/09/2024 Plot Plan APPROVED PLOT PLAN
04/09/2024 Approved Plans APPROVED TRUSS LAYOUT
04/09/2024 Approved Plans APPROVED TRUSS PACKAGE
04/09/2024 Permit Codes Residential Plan Review
04/10/2024 Permit DS Building Permit
04/10/2024 Receipt Receipt for transaction:2024-002294
04/12/2024 3RD Party Insp Report 3216 SW Arbor Sound Dr LSMO Basement Foundation Footing Inspection Report 4-12-24
04/15/2024 Letter INSPECTION SUMMARY
05/01/2024 Letter INSPECTION SUMMARY
05/08/2024 Letter INSPECTION SUMMARY
05/14/2024 Letter INSPECTION SUMMARY
06/12/2024 Letter INSPECTION SUMMARY
07/23/2024 Letter INSPECTION SUMMARY
07/23/2024 Letter INSPECTION SUMMARY
07/23/2024 Letter INSPECTION SUMMARY
07/30/2024 Letter INSPECTION SUMMARY
08/01/2024 Letter INSPECTION SUMMARY
08/07/2024 Letter INSPECTION SUMMARY
08/27/2024 Letter INSPECTION SUMMARY
08/27/2024 Letter INSPECTION SUMMARY
09/05/2024 Letter INSPECTION SUMMARY
09/12/2024 Letter INSPECTION SUMMARY
10/03/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/07/2024 Letter INSPECTION SUMMARY
10/08/2024 Letter INSPECTION SUMMARY
10/08/2024 Letter INSPECTION SUMMARY
10/08/2024 Letter INSPECTION SUMMARY
10/09/2024 Certificate/License Codes Temporary Certificate of Occupancy
10/09/2024 Receipt Receipt for transaction:2024-008210
11/08/2024 Letter Field Certificate of Occupancy
11/08/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home