Summary
PRRES20241195
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
03/14/2024
03/28/2024
09/17/2024
12/13/2024
Locations
Contacts
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
Chad McGraw, Address:902 SE Willow Pl  
chad@mcgraw-homes.com  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
MSSP LLC, Address:13544 BEGEMANN RD, Phone:(816) 365-7067  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 03/28/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 03/28/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 03/28/2024
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 03/28/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 03/28/2024
9110078-Valuation Fee New Single Family $1,900.50 $1,900.50 Paid 03/28/2024
Outstanding Fees Amount Paid Owing Date Paid
9110078-Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid
9110078-Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid


$100.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Water Service Inspection - R Partial 4/22/2024 04/22/2024
Misc
Corrective Action Required
04/22/2024
- Partial, poly out of foundation 20"
Sewer Service Inspection - R Passed 4/22/2024 4/22/2024 04/22/2024
Footing Inspection - Residential Passed 04/30/2024
Informational
04/30/2024
FOOTING APPROVED BY ENGINEER
Underslab Plumbing Inspection - Residential Failed 5/7/2024 5/7/2024 05/07/2024
Misc
Corrective Action Required
05/07/2024
-Insufficient drain tile, should go the entire perimeter or diagonally from one corner all the way to opposite corner
Underslab Plumbing Inspection - Residential Passed 5/8/2024 05/08/2024
Misc
Resolved
05/08/2024
-Insufficient drain tile, should go the entire perimeter or diagonally from one corner all the way to opposite corner
Piers/Caissons Inspection - Residential Passed 5/8/2024 5/8/2024 05/08/2024
Water Service Inspection - R Passed 6/6/2024 6/6/2024 06/06/2024
Misc
Resolved
06/06/2024
- Partial, poly out of foundation 20"
Gas Service Inspection - Residential Failed 7/12/2024 7/12/2024 07/12/2024
Misc
Corrective Action Required
07/12/2024
-Provide min ten psi test pressure
Electrical Service Inspection Passed 7/12/2024 7/12/2024 07/12/2024
All Rough Inspection - Residential Failed 7/12/2024 7/12/2024 07/12/2024
Misc
Corrective Action Required
07/12/2024
-Nail siding to studs and sill plate per code -Protect wiring at garage PFH wall -Install tension straps adjacent to opening -Anchors in garage must be located within middle 1/3 of sill plates -Strap garage top plates lapped less than two ft -Install plumbing vent roof flashings -Support valley rafter at ridge above garage-dwelling door -Protect wiring where located less than 1.25” from surface at: mud closet; near deck door; at bedroom 2 and closet top plates; living room; check throughout -Fb kitchen wall from roof at gaps and penetrations -Nail corner studs per code at deck door; master closet; master bedroom -Complete electrical at rear dining -Provide solid support underneath lvl valley rafter above dryer -Support lvl hip rafter near mid span -Fb stair wall from roof -Fill in gap at basement exterior door with wood per security code -Protect 3” PVC at bedroom 4 closet -Fb bedroom 4 closet walls and bathroom exterior wall from ceiling space; fb all basement wall from ceiling & joist space throughout -Over notched joist above bedroom 4 -Provide (3)2x4 stud support at master bathroom walls per plan **OK TO INSULATE
All Rough Inspection - Residential Failed 7/22/2024 7/22/2024 07/22/2024
Misc
Corrective Action Required
07/12/2024
-Fb bedroom 4 closet walls and bathroom exterior wall from ceiling space; fb all basement wall from ceiling & joist space throughout -Over notched joist above bedroom 4 **Redo return air pan-off
Gas Service Inspection - Residential Passed 7/22/2024 7/22/2024 07/22/2024
Misc
Resolved
07/22/2024
-Provide min ten psi test pressure
Erosion Control Inspection Residential Partial 7/22/2024 07/22/2024
All Rough Inspection - Residential Passed 7/23/2024 7/23/2024 07/23/2024
Misc
Resolved
07/23/2024
-Fb bedroom 4 closet walls and bathroom exterior wall from ceiling space; fb all basement wall from ceiling & joist space throughout -Over notched joist above bedroom 4 **Redo return air pan-off
Driveway Inspection Partial 9/6/2024 9/6/2024 09/06/2024
Misc
Informational
09/06/2024
9-6-24 NS Site visited and it appears driveway meets city standards for pour.
Sidewalk Inspection Partial 9/9/2024 09/09/2024
Misc
Informational
09/09/2024
9-9-24 NS site visited and it appears that sidewalk meets city standards for pre-pour.
Driveway Inspection Passed 9/24/2024 09/24/2024
Misc
Informational
09/06/2024
9-6-24 NS Site visited and it appears driveway meets city standards for pour. 9-24-24 NS Driveway and Sidewalk pass.
Sidewalk Inspection Passed 09/24/2024
Misc
Informational
09/09/2024
9-9-24 NS site visited and it appears that sidewalk meets city standards for pre-pour. 9-24-24 NS Driveway and Sidewalk pass.
Erosion Control Inspection Residential Passed 10/17/2024
Plot Plan Inspection Passed 10/17/2024 10/17/2024
Occupancy Inspection - Codes Residential Ready for Temp CO 10/17/2024 10/17/2024 10/17/2024
Misc
Corrective Action Required
10/17/2024
-Final grade, sod -Support garage receptacle yokes -No power to some garage receptacles -Window located within 24” of deck door must be safety tempered glazing window -Provide AFCI protection for all outlets required per NEC 210.12. (Laundry)
Occupancy Inspection - Codes Residential Ready for Temp CO 10/21/2024 10/21/2024 10/21/2024
Misc
Corrective Action Required
10/17/2024
-Window located within 24” of deck door must be safety tempered glazing window
Occupancy Inspection - Codes Residential Full C of O 12/13/2024 12/13/2024
Misc
Resolved
12/13/2024
-Window located within 24” of deck door must be safety tempered glazing window
Documents & Images
Date Uploaded File Type Document Name
03/14/2024 DW Permit Plan 2025 Lot 383 Park Ridge 4359 NE Hideaway Dr 3-6-24
03/14/2024 383 Park Ridge Staked
03/14/2024 City of Lee's Summit Building Permit
03/14/2024 City of Lee's Summit License_Tax_Application
03/19/2024 Permit Codes Residential Plan Review
03/20/2024 383 Park Ridge Added as graded note
03/20/2024 DW Permit Plan 2025 Lot 383 Park Ridge 4359 NE Hideaway Dr 3-20-24
03/21/2024 Permit Codes Residential Plan Review
03/21/2024 Plot Plan approved plot plan
03/27/2024 DW Permit Plan 2025 Lot 383 Park Ridge 4359 NE Hideaway Dr 3-27-24
03/27/2024 Permit Codes Residential Plan Review
03/27/2024 Approved Plans APPROVED PLANS
03/28/2024 Permit DS Building Permit
03/28/2024 Receipt Receipt for transaction:2024-001970
04/01/2024 Wilmoth 4359 NE Hideaway Dr LSMO McGraw Permit 2024-1195 3rd Party Footing Inspection Report 4-1-24
04/22/2024 Letter INSPECTION SUMMARY
04/22/2024 Letter INSPECTION SUMMARY
05/07/2024 Letter INSPECTION SUMMARY
05/07/2024 Letter INSPECTION SUMMARY
05/08/2024 DW Permit Plan 2025 Lot 383 Park Ridge 4359 NE Hideaway Dr 5-7-24
05/08/2024 Letter INSPECTION SUMMARY
05/08/2024 Approved Plans APPROVED UPDATED PLANS
05/08/2024 Letter INSPECTION SUMMARY
06/06/2024 Letter INSPECTION SUMMARY
07/12/2024 Letter INSPECTION SUMMARY
07/12/2024 Letter INSPECTION SUMMARY
07/12/2024 Letter INSPECTION SUMMARY
07/22/2024 Letter INSPECTION SUMMARY
07/22/2024 Letter INSPECTION SUMMARY
07/23/2024 Letter INSPECTION SUMMARY
07/23/2024 Letter INSPECTION SUMMARY
09/09/2024 Letter INSPECTION SUMMARY
09/09/2024 Letter INSPECTION SUMMARY
09/24/2024 Letter INSPECTION SUMMARY
09/24/2024 Letter INSPECTION SUMMARY
10/16/2024 Plot Plan APPROVED AS GRADED PLOT PLAN
10/17/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
10/21/2024 Letter INSPECTION SUMMARY
12/13/2024 Letter Codes Final Certificate of Occupancy
12/13/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home