Permit Application Status

PRRES20241190


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20241190
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. ROOF TRUSSES. STOP WORK ORDER generated on 04/25/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 04/25/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER generated on 05/02/2024 12:00 AM by username 'Kyle Beard'. STOP WORK ORDER removed on 05/06/2024 12:00 AM by username 'Kyle Beard'. STOP WORK ORDER generated on 08/19/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 08/19/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER generated on 10/17/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 12/02/2024 12:00 AM by username 'Kyle Beard'.
03/14/2024
03/24/2024
09/15/2024
01/10/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,598.10 $1,598.10 Paid 03/24/2024
Water Tap Fee $3,760.00 $3,760.00 Paid 03/24/2024
Water Meter Fee $680.46 $680.46 Paid 03/24/2024
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 03/24/2024
Right of Way Permit Fee $85.00 $85.00 Paid 03/24/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 03/24/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 10/29/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 12/04/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Passed 04/25/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/25/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Erosion Control Inspection Residential Failed 4/29/2024 04/29/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/25/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/29/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. KBEARD
Sewer Service Inspection - R Failed 4/29/2024 4/29/2024 04/29/2024
Miscellaneous Correction
Corrective Action Required
04/29/2024
-Sewer passed and is okay to cover. -Sewer failed due to erosion control measures not being in place
Water Service Inspection - R Passed 5/1/2024 05/01/2024
Underslab Plumbing Inspection - Residential Failed - Stop Work 5/2/2024 5/2/2024 05/02/2024
Miscellaneous Correction
Corrective Action Required
05/02/2024
-Underslab plumbing inspection was not done -Footing inspection was never uploaded or completed -Stop work order is issued on this permit -Work covered without inspection KBEARD
Underslab Plumbing Inspection - Residential Failed - Stop Work 5/3/2024 5/3/2024 05/03/2024
Miscellaneous Correction
Resolved
05/03/2024
-Underslab plumbing inspection was not done -Footing inspection was never uploaded or completed -Stop work order is issued on this permit -Work covered without inspection KBEARD
Miscellaneous Correction
Corrective Action Required
05/03/2024
Underslab plumbing inspection was not done -Footing inspection was never uploaded or completed -Stop work order is issued on this permit -Work covered without inspection KBEARD Documentation of passed footing inspection was not provided. Stop work order is still issued on this permit KBEARD 05/03/2024
Erosion Control Inspection Residential Partial 5/6/2024 05/06/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/06/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/06/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. KBEARD
Miscellaneous Correction
Informational
05/06/2024
Full erosion control is in place and must be maintained until CofO
Footing Inspection - Residential Passed 5/6/2024 05/06/2024
Miscellaneous Correction
Informational
05/06/2024
Footing was passed by a third party. Exterior piers were not included in the footing report
Underslab Plumbing Inspection - Residential Passed 5/6/2024 5/6/2024 05/06/2024
Miscellaneous Correction
Resolved
05/06/2024
Underslab plumbing inspection was not done -Footing inspection was never uploaded or completed -Stop work order is issued on this permit -Work covered without inspection KBEARD Documentation of passed footing inspection was not provided. Stop work order is still issued on this permit KBEARD 05/03/2024
Sewer Service Inspection - R Passed 6/4/2024 06/04/2024
Miscellaneous Correction
Resolved
06/04/2024
-Sewer passed and is okay to cover. -Sewer failed due to erosion control measures not being in place
All Rough Inspection - Residential Failed 6/4/2024 6/4/2024 06/04/2024
Miscellaneous Correction
Corrective Action Required
06/04/2024
- Exterior East side of garage sheeting does not extend to the upper top plate - Exterior of garage sheeting must be fastened to both top plates - Exterior of North side CSPF is not fastened in any pattern
Erosion Control Inspection Residential Partial 6/4/2024 06/04/2024
Miscellaneous Correction
Resolved
06/04/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Informational
06/04/2024
Full erosion control is in place and must be maintained until CofO
All Rough Inspection - Residential Failed 6/14/2024 6/14/2024 06/14/2024
Miscellaneous Correction
Corrective Action Required
06/04/2024
- Exterior East side of garage sheeting does not extend to the upper top plate - Exterior of garage sheeting must be fastened to both top plates - Exterior of North side CSPF is not fastened in any pattern
Misc
Corrective Action Required
06/14/2024
-Inspection denied no drawings on site
All Rough Inspection - Residential Failed 7/3/2024 7/3/2024 07/03/2024
Miscellaneous Correction
Resolved
07/03/2024
- Exterior East side of garage sheeting does not extend to the upper top plate - Exterior of garage sheeting must be fastened to both top plates - Exterior of North side CSPF is not fastened in any pattern
Misc
Resolved
07/03/2024
-Inspection denied no drawings on site
Miscellaneous Correction
Corrective Action Required
07/03/2024
Builder asked for the exterior garage portal sheeting inspection only. -As stated by the inspector from the last inspection. Exterior garage sheeting must be nailed to both top plates. Have full erosion control measures in place before rescheduling all rough inspection
Erosion Control Inspection Residential Failed 7/3/2024 07/03/2024
Miscellaneous Correction
Resolved
07/03/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
07/03/2024
Erosion control is torn down, damaged or missing along the properties west side. Erosion control is missing along the properties front east side Full erosion control measures must be maintained until CofO
All Rough Inspection - Residential Failed 7/15/2024 7/15/2024 07/15/2024
Miscellaneous Correction
Resolved
07/15/2024
Builder asked for the exterior garage portal sheeting inspection only. -As stated by the inspector from the last inspection. Exterior garage sheeting must be nailed to both top plates. Have full erosion control measures in place before rescheduling all rough inspection
Miscellaneous Correction
Informational
07/15/2024
Garage exterior sheeting portal passed and is okay to cover This is a partial pass only. The interior of the garage was not inspected
Erosion Control Inspection Residential Partial 7/15/2024 07/15/2024
Miscellaneous Correction
Informational
07/15/2024
Erosion control is torn down, damaged or missing along the properties west side. Erosion control is missing along the properties front east side Full erosion control measures must be maintained until CofO
Miscellaneous Correction
Informational
07/15/2024
Erosion control is in place and must be maintained until CofO
Gas Service Inspection - Residential Passed 7/19/2024 07/19/2024
Electrical Service Inspection Failed 7/19/2024 07/19/2024
Miscellaneous Correction
Corrective Action Required
07/19/2024
Electrical fixtures are hanging from the top plate in bath 2
All Rough Inspection - Residential Failed 7/19/2024 7/19/2024 07/19/2024
Miscellaneous Correction
Resolved
07/19/2024
Garage exterior sheeting portal passed and is okay to cover This is a partial pass only. The interior of the garage was not inspected
Miscellaneous Correction
Corrective Action Required
07/19/2024
2134 SW Rutherford. All rough -Garage south side anchor bolts are not spaced according to code -Garage anchor bolts can not be placed closer than 4 inches from the end of each sole plate -Fire block top of chase in garage to entry closet -LIB in garage N/W corner nail pattern could not be accessed for inspection -Missing joist hangers in powder bathroom at waste line -Fire block top of chase in pantry at ventilation ductwork -Nail kitchen exterior corner to code -Kitchen window header is not a 2x10 -Nail missing in joist hanger at dining room/entry closet at triple 2x10 -Have engineer address holes cut in double floor joist in dining room (2 inches from bottom side and 2 inches or closer to water line) -Truss hangers are not installed on the front porch -Girder truss in upper stairwell does not have a (4) 2x6 stud pack as per plan -Upper stair stringer beam does not bear 1 1/2 inches against double 2x10 beam -Roof boot jackets are not installed -Electrical fixtures are hanging from the top plate in bath2 -Stair platform going to the basement from the main entry is not supported at the S/E corner -Stair stringer beams in basement to first platform does not bear 1 1/2 inches up against the 2x10 platform
Electrical Service Inspection Passed 7/25/2024 07/25/2024
Miscellaneous Correction
Resolved
07/25/2024
Electrical fixtures are hanging from the top plate in bath 2
All Rough Inspection - Residential Failed 7/25/2024 7/25/2024 07/25/2024
Miscellaneous Correction
Resolved
07/25/2024
2134 SW Rutherford. All rough -Garage south side anchor bolts are not spaced according to code -Garage anchor bolts can not be placed closer than 4 inches from the end of each sole plate -Fire block top of chase in garage to entry closet -LIB in garage N/W corner nail pattern could not be accessed for inspection -Missing joist hangers in powder bathroom at waste line -Fire block top of chase in pantry at ventilation ductwork -Nail kitchen exterior corner to code -Kitchen window header is not a 2x10 -Nail missing in joist hanger at dining room/entry closet at triple 2x10 -Have engineer address holes cut in double floor joist in dining room (2 inches from bottom side and 2 inches or closer to water line) -Truss hangers are not installed on the front porch -Girder truss in upper stairwell does not have a (4) 2x6 stud pack as per plan -Upper stair stringer beam does not bear 1 1/2 inches against double 2x10 beam -Roof boot jackets are not installed -Electrical fixtures are hanging from the top plate in bath2 -Stair platform going to the basement from the main entry is not supported at the S/E corner -Stair stringer beams in basement to first platform does not bear 1 1/2 inches up against the 2x10 platform
Miscellaneous Correction
Corrective Action Required
07/25/2024
2134 SW Rutherford. All rough (2) -Garage anchor bolts can not be placed closer than 4 inches and no more than 12 inches from the end of each sole plate -Nail kitchen exterior corner to code -Fire block holes in top plate of bathroom 2 -Stair platform going to the basement from the main entry is not supported at the S/E corner (2x4 vertical brace installed is non treated lumber in contact with cement) -Stair stringer beams in basement to first platform does not bear 1 1/2 inches up against the 2x10 platform
All Rough Inspection - Residential Failed 7/26/2024 7/26/2024 07/26/2024
Miscellaneous Correction
Partial Correction
07/26/2024
2134 SW Rutherford. All rough (2) -Stair platform going to the basement from the main entry is not supported at the S/E corner (2x4 vertical brace installed is non treated lumber in contact with cement)
All Rough Inspection - Residential Passed 7/26/2024 07/26/2024
Miscellaneous Correction
Resolved
07/26/2024
Driveway Inspection Partial 8/1/2024 08/01/2024
Misc
Informational
08/01/2024
8-1-24 PS Driveway approach pre pour, forms in place aggregate compacted, approved to pour
Sidewalk Inspection Partial 8/1/2024 08/01/2024
Misc
Informational
08/01/2024
8-1-24 PS Sidewalk pre pour, forms in place, aggregate compacted, approved to pour
Erosion Control Inspection Residential Partial 8/14/2024 8/14/2024 08/14/2024
Miscellaneous Correction
Informational
07/15/2024
Erosion control is torn down, damaged or missing along the properties west side. Erosion control is missing along the properties front east side Full erosion control measures must be maintained until CofO
Miscellaneous Correction
Informational
07/15/2024
Erosion control is in place and must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/14/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. All silt needs to be cleaned off of approach and sidewalks
Driveway Inspection Partial 8/15/2024 8/14/2024 08/14/2024
Misc
Informational
08/01/2024
8-1-24 PS Driveway approach pre pour, forms in place aggregate compacted, approved to pour 8-14-24 Dustin A, Met with Andrew with Summit. Inspection was accidently scheduled. I informed him silt needed to be cleaned from approaches and sidewalks before development could sign off. He also has a broken water valve top and a street sign down.
Sidewalk Inspection Partial 8/15/2024 8/14/2024 08/14/2024
Misc
Informational
08/14/2024
8-14-24 Dustin A, Met with Andrew with Summit. Inspection was accidently scheduled. I informed him silt needed to be cleaned from approaches and sidewalks before development could sign off. He also has a broken water valve top and a street sign down.
Driveway Inspection Partial 8/15/2024 8/15/2024 08/15/2024
Misc
Informational
08/14/2024
8-1-24 PS Driveway approach pre pour, forms in place aggregate compacted, approved to pour 8-14-24 Dustin A, Met with Andrew with Summit. Inspection was accidently scheduled. I informed him silt needed to be cleaned from approaches and sidewalks before development could sign off. He also has a broken water valve top and a street sign down.
Sidewalk Inspection Partial 8/15/2024 8/15/2024 08/15/2024
Erosion Control Inspection Residential Failed - Stop Work 8/19/2024 8/19/2024 08/19/2024
Miscellaneous Correction
Informational
08/14/2024
Erosion control is torn down, damaged or missing along the properties west side. Erosion control is missing along the properties front east side Full erosion control measures must be maintained until CofO
Miscellaneous Correction
Informational
08/14/2024
Erosion control is in place and must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/14/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. All silt needs to be cleaned off of approach and sidewalks 8-19-24 Dustin A SW's and ADA ramp still has silt and dirt on it.
Erosion Control Inspection Residential Partial 8/19/2024 8/19/2024 08/19/2024
Miscellaneous Correction
Informational
08/19/2024
Erosion control is torn down, damaged or missing along the properties west side. Erosion control is missing along the properties front east side Full erosion control measures must be maintained until CofO
Miscellaneous Correction
Informational
08/19/2024
Erosion control is in place and must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/19/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. All silt needs to be cleaned off of approach and sidewalks 8-19-24 Dustin A SW's and ADA ramp still has silt and dirt on it. 8-19-24 Dustin A . SW's has been cleaned, Will need to maintain erosion control until completion
Driveway Inspection Partial 8/30/2024 8/30/2024 08/29/2024
Misc
Corrective Action Required
08/29/2024
8-29-24 Dustin A, DW has been poured. Forms pulled., Development will not sign off until stop sign is fixed
Sidewalk Inspection Partial 8/29/2024 8/29/2024 08/29/2024
Misc
Informational
08/29/2024
8-29-24 DA. Met with Andrew with summit, went over some trip hazards that were in the SW that needs to be fixed.
Erosion Control Inspection Residential Failed 9/6/2024 09/06/2024
Miscellaneous Correction
Resolved
09/06/2024
Erosion control is torn down, damaged or missing along the properties west side. Erosion control is missing along the properties front east side Full erosion control measures must be maintained until CofO
Miscellaneous Correction
Resolved
09/06/2024
Erosion control is in place and must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Resolved
09/06/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. All silt needs to be cleaned off of approach and sidewalks 8-19-24 Dustin A SW's and ADA ramp still has silt and dirt on it. 8-19-24 Dustin A . SW's has been cleaned, Will need to maintain erosion control until completion
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/06/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Erosion control is torn down, damaged or missing along the properties east side, west side and at the front of the property by the street Full erosion control measures must be maintained until CofO
Occupancy Inspection - Codes Residential Failed 9/9/2024 9/9/2024 09/09/2024
Miscellaneous Correction
Corrective Action Required
09/09/2024
4 DCM1 ESC REQUIRED NO FURTHER INSP Comments: Inspector: Outcome: Date: Kyle Beard Failed Friday, September 06, 2024 EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Erosion control is torn down, damaged or missing along the properties east side, west side and at the front of the property by the street Full erosion control measures must be maintained until CofO A drive by inspection was done this morning at 8:35am and no improvements were made 09/09/2024 KBEARD
Erosion Control Inspection Residential Partial 9/10/2024 09/10/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
09/10/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Erosion control is torn down, damaged or missing along the properties east side, west side and at the front of the property by the street Full erosion control measures must be maintained until CofO
Miscellaneous Correction
Informational
09/10/2024
Full erosion control measures are in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Failed 9/10/2024 9/10/2024 09/10/2024
Miscellaneous Correction
Resolved
09/10/2024
4 DCM1 ESC REQUIRED NO FURTHER INSP Comments: Inspector: Outcome: Date: Kyle Beard Failed Friday, September 06, 2024 EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Erosion control is torn down, damaged or missing along the properties east side, west side and at the front of the property by the street Full erosion control measures must be maintained until CofO A drive by inspection was done this morning at 8:35am and no improvements were made 09/09/2024 KBEARD
Miscellaneous Correction
Corrective Action Required
09/10/2024
2134 SW Rutherford. Occupancy Fire block gaps in sheet rock in garage at ceiling and north wall to house along sole plate Refrigerator and microwave breaker needs to be AFCI protected Remove dust covers on smoke detectors First stair riser from main living area to upstairs has a height greater than 7 3/4 inches Cold water line above the water heater is not secured Sump pump receptacle needs to state it is non GFCI protected Electrical in basement at stairwell is not fully secured and has gaps to sheet rock Sod, splash pads and sump pump extension is not installed Seal gas line to siding penetration Sidewalk and driveway inspection needs to pass
Erosion Control Inspection Residential Partial 9/13/2024 09/13/2024
Miscellaneous Correction
Informational
09/10/2024
Full erosion control measures are in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Failed 9/13/2024 9/13/2024 09/13/2024
Miscellaneous Correction
Resolved
09/13/2024
2134 SW Rutherford. Occupancy Fire block gaps in sheet rock in garage at ceiling and north wall to house along sole plate Refrigerator and microwave breaker needs to be AFCI protected Remove dust covers on smoke detectors First stair riser from main living area to upstairs has a height greater than 7 3/4 inches Cold water line above the water heater is not secured Sump pump receptacle needs to state it is non GFCI protected Electrical in basement at stairwell is not fully secured and has gaps to sheet rock Sod, splash pads and sump pump extension is not installed Seal gas line to siding penetration Sidewalk and driveway inspection needs to pass
Miscellaneous Correction
Corrective Action Required
09/13/2024
2134 SW Rutherford. Occupancy (2) -Fire block gaps in sheet rock north wall to house at sole plate (still have gaps) -Sod, splash pads and sump pump extension is not installed -Lower water meter to grade -Sidewalk and driveway inspections need to pass
Sidewalk Inspection Failed 9/16/2024 9/16/2024 09/16/2024
Misc
Corrective Action Required
09/16/2024
9-16-24 Dustin A, the panels that were causing a trip hazard have been ground down. The ada warning pad that was damaged has not been replaced still. Will not pass until corrected as well as street sign and stop sign is replaced. Contacted Andrew and discussed with him
Sidewalk Inspection Failed 9/16/2024 9/16/2024 09/16/2024
Misc
Informational
09/16/2024
8-29-24 DA. Met with Andrew with summit, went over some trip hazards that were in the SW that needs to be fixed. 9-16-24 Dustin A, SW hazards have been fixed. ADA warning pad has not been replaced. Cannot sign off until that and street sign is replaced.
Driveway Inspection Failed 09/16/2024
Misc
Informational
08/15/2024
8-1-24 PS Driveway approach pre pour, forms in place aggregate compacted, approved to pour 8-14-24 Dustin A, Met with Andrew with Summit. Inspection was accidently scheduled. I informed him silt needed to be cleaned from approaches and sidewalks before development could sign off. He also has a broken water valve top and a street sign down. 9-16-24 Dustin A, Dw has been formed to city specs and slopes are in compliance. Cannot pass until Street and stop sign are replaced.
Driveway Inspection Failed 9/16/2024 9/16/2024 09/16/2024
Occupancy Inspection - Codes Residential Ready for Temp CO 9/23/2024 9/23/2024 09/23/2024
Miscellaneous Correction
Resolved
09/23/2024
2134 SW Rutherford. Occupancy (2) -Fire block gaps in sheet rock north wall to house at sole plate (still have gaps) -Sod, splash pads and sump pump extension is not installed -Sidewalk and driveway inspections need to pass
Miscellaneous Correction
Corrective Action Required
09/23/2024
2134 SW Rutherford. Occupancy (2) -Sod, splash pads and sump pump extension is not installed -Sidewalk and driveway inspections need to pass
Driveway Inspection Passed 10/14/2024 10/14/2024 10/14/2024
Misc
Informational
10/14/2024
10-14-24 Dustin A, DW is poured to city specs, Slopes are in compliance, Pass
Erosion Control Inspection Residential Failed 10/14/2024 10/14/2024 10/14/2024
Miscellaneous Correction
Informational
09/13/2024
Full erosion control measures are in place and must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/14/2024
10-14-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. silt fence is down in areas
Erosion Control Inspection Residential Failed - Stop Work 10/17/2024 10/17/2024 10/17/2024
Miscellaneous Correction
Informational
10/14/2024
Full erosion control measures are in place and must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/14/2024
10-14-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. silt fence is down in areas 10-17-24 Dustin A, Not corrected and gutter splashes stacked on ADA ramp
Occupancy Inspection - Codes Residential Failed 10/25/2024 10/25/2024
Miscellaneous Correction
Resolved
10/25/2024
2134 SW Rutherford. Occupancy (2) -Sod, splash pads and sump pump extension is not installed -Sidewalk and driveway inspections need to pass
Miscellaneous Correction
Corrective Action Required
10/25/2024
2134 SW Rutherford. Occupancy (3) -Sod, splash pads and sump pump extension is not installed -Sidewalk and driveway inspections need to pass TCO has expired, send in a TCO extension form to keep this permit active KBEARD 10/25/2024
Erosion Control Inspection Residential Failed 11/1/2024 11/01/2024
Miscellaneous Correction
Informational
10/17/2024
Full erosion control measures are in place and must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/17/2024
10-14-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. silt fence is down in areas 10-17-24 Dustin A, Not corrected and gutter splashes stacked on ADA ramp
Erosion Control Inspection Residential Partial 12/2/2024 12/02/2024
Miscellaneous Correction
Resolved
12/02/2024
Full erosion control measures are in place and must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Resolved
12/02/2024
10-14-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. silt fence is down in areas 10-17-24 Dustin A, Not corrected and gutter splashes stacked on ADA ramp
Miscellaneous Correction
Informational
12/02/2024
Erosion control measures are in place and must be properly maintained until CofO
Occupancy Inspection - Codes Residential Failed 12/2/2024 12/02/2024
Miscellaneous Correction
Resolved
12/02/2024
2134 SW Rutherford. Occupancy (3) -Sod, splash pads and sump pump extension is not installed -Sidewalk and driveway inspections need to pass TCO has expired, send in a TCO extension form to keep this permit active KBEARD 10/25/2024
Miscellaneous Correction
Corrective Action Required
12/02/2024
2134 SW Rutherford. Occupancy (3) -Sod, splash pads and sump pump extension is not installed -Sidewalk inspection needs to pass TCO has expired, send in a TCO extension letter to the builder to keep this permit active KBEARD 12/02/2024
Plot Plan Inspection Passed 12/30/2024 12/03/2024
Sidewalk Inspection Passed 01/03/2025
Misc
Informational
09/16/2024
8-29-24 DA. Met with Andrew with summit, went over some trip hazards that were in the SW that needs to be fixed. 9-16-24 Dustin A, SW hazards have been fixed. ADA warning pad has not been replaced. Cannot sign off until that and street sign is replaced. 1-3-24 Dustin A, SW has passed
Sidewalk Inspection Passed 01/03/2025
Erosion Control Inspection Residential Passed 1/3/2025 01/03/2025
Miscellaneous Correction
Resolved
01/03/2025
Erosion control measures are in place and must be properly maintained until CofO
Plot Plan Inspection Passed 1/3/2025 01/03/2025
Occupancy Inspection - Codes Residential Full C of O 1/10/2025 01/10/2025
Miscellaneous Correction
Resolved
01/10/2025
2134 SW Rutherford. Occupancy (3) -Sod, splash pads and sump pump extension is not installed -Sidewalk inspection needs to pass TCO has expired, send in a TCO extension letter to the builder to keep this permit active KBEARD 12/02/2024
Documents & Images
Date Uploaded File Type Document Name
03/14/2024 OS # 75 - ENGINEERED PLANS
03/14/2024 OS # 75 - PERMIT APP
03/14/2024 OS # 75 - PLOT PLAN
03/14/2024 OS # 75 - TRUSS DETAILS
03/14/2024 OS # 75 - TRUSS LAYOUT
03/19/2024 OS 75 - PLANS - CITY COMMENTS
03/19/2024 Permit Codes Residential Plan Review
03/19/2024 Approved Plans APPROVED PLANS
03/19/2024 Approved Plans APPROVED TRUSS LAYOUT
03/19/2024 Approved Plans APPROVED TRUSS PACKAGE
03/22/2024 LOT 75 CITY
03/22/2024 Plot Plan APPROVED PLOT PLAN
03/22/2024 Permit Codes Residential Plan Review
03/24/2024 Permit DS Building Permit
03/24/2024 Receipt Receipt for transaction:2024-001836
04/25/2024 Letter Stop Work Order
04/25/2024 Letter Stop Work Order
04/25/2024 Letter INSPECTION SUMMARY
04/29/2024 Letter INSPECTION SUMMARY
04/29/2024 Letter INSPECTION SUMMARY
04/29/2024 Letter INSPECTION SUMMARY
05/01/2024 Letter INSPECTION SUMMARY
05/02/2024 Letter Stop Work Order
05/03/2024 Letter Stop Work Order
05/03/2024 3RD Party Insp Report THIRD PARTY FOOTING INSPECTION
05/06/2024 Letter INSPECTION SUMMARY
05/06/2024 Letter INSPECTION SUMMARY
05/06/2024 Letter INSPECTION SUMMARY
06/04/2024 Letter INSPECTION SUMMARY
06/04/2024 Letter INSPECTION SUMMARY
06/04/2024 Letter INSPECTION SUMMARY
06/14/2024 Letter INSPECTION SUMMARY
07/03/2024 Letter INSPECTION SUMMARY
07/03/2024 Letter INSPECTION SUMMARY
07/15/2024 Letter INSPECTION SUMMARY
07/15/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter INSPECTION SUMMARY
07/23/2024 Engineer Report/Study ENGINEER LETTER
07/25/2024 3RD Party Insp Report OS 75- FRAMING CORRECTION - 240424
07/25/2024 Letter INSPECTION SUMMARY
07/25/2024 Letter INSPECTION SUMMARY
07/26/2024 Letter INSPECTION SUMMARY
07/26/2024 Letter INSPECTION SUMMARY
07/26/2024 Letter INSPECTION SUMMARY
08/01/2024 Letter INSPECTION SUMMARY
08/01/2024 Letter INSPECTION SUMMARY
08/14/2024 Letter INSPECTION SUMMARY
08/14/2024 Letter INSPECTION SUMMARY
08/14/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter Stop Work Order
08/19/2024 Letter Stop Work Order
08/19/2024 Letter INSPECTION SUMMARY
08/29/2024 Letter INSPECTION SUMMARY
08/29/2024 Letter INSPECTION SUMMARY
09/06/2024 Letter INSPECTION SUMMARY
09/09/2024 Letter INSPECTION SUMMARY
09/10/2024 Letter INSPECTION SUMMARY
09/10/2024 Letter INSPECTION SUMMARY
09/13/2024 Letter INSPECTION SUMMARY
09/13/2024 Letter INSPECTION SUMMARY
09/16/2024 Letter INSPECTION SUMMARY
09/16/2024 Letter INSPECTION SUMMARY
09/16/2024 Letter INSPECTION SUMMARY
09/16/2024 Letter INSPECTION SUMMARY
09/23/2024 Letter INSPECTION SUMMARY
10/14/2024 Letter INSPECTION SUMMARY
10/14/2024 Letter INSPECTION SUMMARY
10/14/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter Stop Work Order
10/17/2024 Letter Stop Work Order
10/25/2024 Letter INSPECTION SUMMARY
10/29/2024 OS #75 - TCO extension form 10_29_24
10/29/2024 Certificate/License Codes Temporary Certificate of Occupancy
10/29/2024 Receipt Receipt for transaction:2024-008645
11/01/2024 Letter INSPECTION SUMMARY
12/02/2024 Letter INSPECTION SUMMARY
12/02/2024 Letter INSPECTION SUMMARY
12/02/2024 Letter INSPECTION SUMMARY
12/03/2024 OS #75 - TCO extension form 12_3_24
12/04/2024 Certificate/License Codes Temporary Certificate of Occupancy
12/04/2024 Receipt Receipt for transaction:2024-009342
12/27/2024 Plot Plan approved as graded plot plan
01/03/2025 Letter INSPECTION SUMMARY
01/03/2025 Letter INSPECTION SUMMARY
01/03/2025 Letter INSPECTION SUMMARY
01/03/2025 Letter INSPECTION SUMMARY
01/10/2025 Letter Codes Final Certificate of Occupancy
01/10/2025 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home