Permit Application Status

PRRES20240962


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20240962
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE. FINISHED BASEMENT. ROOF TRUSSES - DEFERRED. UNCOVERED DECK.
03/01/2024
03/19/2024
09/04/2024
07/29/2024
Locations
Contacts
Avital Homes, LLC, Address:7500 W 151st Street, #23100, Phone:(816) 914-7128  
CMH PARKS INC, Address:5000 CLAYTON RD  
Doug Jenson, Address:11010 Nora Dodge Dr, Phone:(816) 266-0685  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
DOUG@APGKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 03/19/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 03/19/2024
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 03/19/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 03/19/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 03/19/2024
9110078-Valuation Fee New Single Family $1,239.33 $1,239.33 Paid 03/19/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 07/18/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 10/18/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/22/2024 3/22/2024 03/22/2024
Miscellaneous Correction
Informational
03/22/2024
Eufer is located along the garage west wall
Sewer Service Inspection - R Passed 4/3/2024 4/3/2024 04/03/2024
Water Service Inspection - R Failed 4/4/2024 4/4/2024 04/04/2024
Miscellaneous Correction
Corrective Action Required
04/04/2024
-Water passed and is okay to cover -gravel needs to be spread in driveway to foundation and torn down or missing silt fence needs to be replaced or repaired for proper erosion control measures -no further inspections until full erosion control measures are completed
Underslab Plumbing Inspection - Residential Passed 4/5/2024 4/5/2024 04/05/2024
Water Service Inspection - R Passed 4/5/2024 04/05/2024
Miscellaneous Correction
Resolved
04/05/2024
-Water passed and is okay to cover -gravel needs to be spread in driveway to foundation and torn down or missing silt fence needs to be replaced or repaired for proper erosion control measures -no further inspections until full erosion control measures are completed
Erosion Control Inspection Residential Failed 4/8/2024 04/08/2024
Miscellaneous Correction
Corrective Action Required
04/08/2024
- Silt fence between this property and 1921 SW MERRYMAN Ned’s to be repaired or replaced - gravel needs to be spread from the street to the foundation
Erosion Control Inspection Residential Partial 5/3/2024 05/03/2024
Miscellaneous Correction
Resolved
05/03/2024
- Silt fence between this property and 1921 SW MERRYMAN Ned’s to be repaired or replaced - gravel needs to be spread from the street to the foundation
Miscellaneous Correction
Informational
05/03/2024
Full erosion control is in place and must be maintained until CofO
All Rough Inspection - Residential Partial 5/9/2024 5/9/2024 05/09/2024
Miscellaneous Correction
Informational
05/09/2024
Garage portal inspection only. Passed and ok to cover This is a partial pass only
Erosion Control Inspection Residential Failed 5/15/2024 05/15/2024
Miscellaneous Correction
Resolved
05/15/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
05/15/2024
Repair or replace silt fence at the street where it is damaged. Full erosion control must be maintained until CofO
Gas Service Inspection - Residential Passed 5/23/2024 5/23/2024 05/23/2024
Electrical Service Inspection Passed 5/23/2024 5/23/2024 05/23/2024
All Rough Inspection - Residential Failed 5/23/2024 5/23/2024 05/23/2024
Miscellaneous Correction
Informational
05/09/2024
Garage portal inspection only. Passed and ok to cover This is a partial pass only
Miscellaneous Correction
Corrective Action Required
05/23/2024
1925 SW Merryman. All rough •Garage anchor bolts need to be in the middle 1/3 of sole plate •Garage anchor bolts need to be within 4-12 inches from the end of the sole plate •Fire block garage to house chase at the top •Nail pantry outside corner to code •Bedroom 2 N/E corner needs a continuous stud at stud installed •Primary toilet area needs a truss tie down screw installed •Primary bathroom toilet window needs a king stud installed west side •Electrical nail guard is need in primary bedroom north wall •Fire block double top plate between primary and TV •Mechanical HVAC piping needs to have BOCA plates at the top plate and sole plate
All Rough Inspection - Residential Passed 5/29/2024 5/29/2024 05/29/2024
Misc
Informational
05/28/2024
Miscellaneous Correction
Resolved
05/29/2024
•Fire block garage to house chase at the top •Bedroom 2 fire blockk wall space to celing space -fire block furr down ends in basement Mechanical HVAC piping needs to have BOCA plates at the top plate and sole plate
Erosion Control Inspection Residential Partial 06/10/2024
Miscellaneous Correction
Corrective Action Required
05/15/2024
Repair or replace silt fence at the street where it is damaged. Full erosion control must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/10/2024
6-10-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Street needs to be cleaned
Erosion Control Inspection Residential Passed 6/13/2024 6/13/2024 06/12/2024
Miscellaneous Correction
Corrective Action Required
06/10/2024
Repair or replace silt fence at the street where it is damaged. Full erosion control must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/10/2024
6-10-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Street needs to be cleaned 6-12-24 Dustin A, Street has been cleaned and erosion control is in place
Piers/Caissons Inspection - Residential Failed 7/2/2024 07/02/2024
Miscellaneous Correction
Corrective Action Required
07/02/2024
House address numbers must be posted before scheduling inspections
Driveway Inspection Partial 7/2/2024 7/2/2024 07/02/2024
Misc
Informational
07/02/2024
7-2-24 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour
Sidewalk Inspection Partial 7/2/2024 7/2/2024 07/02/2024
Misc
Informational
07/02/2024
7-2-24 PS Sidewalk pre pour, forms in place and aggregate compacted, approved to pour
Piers/Caissons Inspection - Residential Not Ready 7/3/2024 7/3/2024 07/03/2024
Miscellaneous Correction
Resolved
07/03/2024
House address numbers must be posted before scheduling inspections
Miscellaneous Correction
Corrective Action Required
07/03/2024
-Pier holes are full of water -Remove water and reschedule for inspection Not ready. Walk your property before scheduling an inspection Time 10:20am. KBEARD
Piers/Caissons Inspection - Residential Failed 7/3/2024 07/03/2024
Miscellaneous Correction
Resolved
07/03/2024
-Pier holes are full of water -Remove water and reschedule for inspection Not ready. Walk your property before scheduling an inspection Time 10:20am. KBEARD
Miscellaneous Correction
Corrective Action Required
07/03/2024
Pier holes are full of water -Remove water and reschedule for inspection Inspectors usually can not give you an exact time of inspection. Have all work completed before scheduling a inspection Time 1:38 pm. KBEARD
Piers/Caissons Inspection - Residential Passed 7/8/2024 7/8/2024 07/08/2024
Miscellaneous Correction
Resolved
07/08/2024
Pier holes are full of water -Remove water and reschedule for inspection Inspectors usually can not give you an exact time of inspection. Have all work completed before scheduling a inspection Time 1:38 pm. KBEARD
Driveway Inspection Passed 7/9/2024 7/9/2024 07/08/2024
Misc
Informational
07/02/2024
7-2-24 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour 7-8-24 driveway approach meets LS and ADA specs
Sidewalk Inspection Passed 7/9/2024 7/9/2024 07/08/2024
Misc
Informational
07/02/2024
7-2-24 PS Sidewalk pre pour, forms in place and aggregate compacted, approved to pour 7-8-24 PS Sidewalk meets ADA and LS specs
Erosion Control Inspection Residential Partial 7/17/2024 07/17/2024
Miscellaneous Correction
Informational
07/17/2024
Full erosion control measures are in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Failed 7/17/2024 7/17/2024 07/17/2024
Miscellaneous Correction
Corrective Action Required
07/17/2024
1925 SW Merryman. Occupancy Remove dust covers from smoke detectors Front bathroom vent fan is not installed Master bathroom vent fan is not installed Fireplace is not installed Garage to house self closing door does not have its seal installed and could not be inspected Fire block all gaps in sheet rock in garage Garage attic access hatches are not installed Basement bathroom vent fan not installed Sod, sump pump extensions and splash pads are not installed Pay $75 fee associated with this permit
Occupancy Inspection - Codes Residential Ready for Temp CO 7/23/2024 7/23/2024 07/23/2024
Miscellaneous Correction
Resolved
07/23/2024
1925 SW Merryman. Occupancy Remove dust covers from smoke detectors Front bathroom vent fan is not installed Master bathroom vent fan is not installed Fireplace is not installed Garage to house self closing door does not have its seal installed and could not be inspected Fire block all gaps in sheet rock in garage Garage attic access hatches are not installed Basement bathroom vent fan not installed Sod, sump pump extensions and splash pads are not installed Pay $75 fee associated with this permit
Miscellaneous Correction
Corrective Action Required
07/23/2024
Sod, sump pump extensions seal all exterior penetrations and splash pads are not installed Passed for TCO only
Erosion Control Inspection Residential Partial 7/23/2024 07/23/2024
Miscellaneous Correction
Resolved
07/23/2024
Full erosion control measures are in place and must be maintained until CofO
Miscellaneous Correction
Informational
07/23/2024
Full erosion control measures are in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Full C of O 7/29/2024 7/29/2024 07/29/2024
Miscellaneous Correction
Resolved
07/29/2024
Documents & Images
Date Uploaded File Type Document Name
03/01/2024 133 Manor at Stoney Creek - Serenade - 022824
03/01/2024 LOT 133 FINAL
03/01/2024 MN 133 License_Tax_Application
03/01/2024 MN 133 LS Residental Permit Application_1
03/06/2024 Permit Codes Residential Plan Review
03/07/2024 LOT 133 CITY
03/07/2024 133 Manor at Stoney Creek - Serenade - 030724
03/07/2024 1925 SW MERRYMAN DR RESPONSE LETTER
03/08/2024 Permit Codes Residential Plan Review
03/12/2024 Plot Plan APPROVED PLOT PLAN
03/12/2024 133 Manor at Stoney Creek - Serenade - 031224
03/13/2024 Approved Plans APPROVED PLANS
03/13/2024 Permit Codes Residential Plan Review
03/19/2024 Permit DS Building Permit
03/19/2024 Receipt Receipt for transaction:2024-001720
03/22/2024 Letter INSPECTION SUMMARY
03/22/2024 Letter INSPECTION SUMMARY
03/22/2024 3RD Party Insp Report 133 Manor at Stoney Creek - Subgrade
04/03/2024 Letter INSPECTION SUMMARY
04/04/2024 Letter INSPECTION SUMMARY
04/05/2024 Letter INSPECTION SUMMARY
04/05/2024 Letter INSPECTION SUMMARY
04/08/2024 Letter INSPECTION SUMMARY
04/20/2024 240616 Layout
04/20/2024 240616 Seals
04/22/2024 Approved Plans APPROVED TRUSS PACKAGE
05/03/2024 Letter INSPECTION SUMMARY
05/09/2024 Letter INSPECTION SUMMARY
05/15/2024 Letter INSPECTION SUMMARY
05/16/2024 3RD Party Insp Report TRUSS REPAIR
05/28/2024 Letter INSPECTION SUMMARY
05/29/2024 Letter INSPECTION SUMMARY
06/10/2024 Letter INSPECTION SUMMARY
06/10/2024 Letter INSPECTION SUMMARY
06/12/2024 Letter INSPECTION SUMMARY
07/02/2024 Letter INSPECTION SUMMARY
07/02/2024 Letter INSPECTION SUMMARY
07/02/2024 Letter INSPECTION SUMMARY
07/02/2024 Letter INSPECTION SUMMARY
07/02/2024 Letter INSPECTION SUMMARY
07/02/2024 Letter INSPECTION SUMMARY
07/03/2024 Letter INSPECTION SUMMARY
07/03/2024 Letter INSPECTION SUMMARY
07/08/2024 Letter INSPECTION SUMMARY
07/08/2024 Letter INSPECTION SUMMARY
07/08/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/18/2024 Receipt Receipt for transaction:2024-005940
07/23/2024 Letter INSPECTION SUMMARY
07/23/2024 Letter INSPECTION SUMMARY
07/29/2024 Letter Codes Final Certificate of Occupancy
07/29/2024 Letter Field Certificate of Occupancy
10/18/2024 Certificate/License Codes Temporary Certificate of Occupancy
10/18/2024 Receipt Receipt for transaction:2024-008437
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home