Permit Application Status

PRRES20240334


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20240334
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE (Continuation of New Residential Build). FINISHED/UNFINISHED BASEMENT. ROOF TRUSSES. UNCOVERED PATIO. *Foundation up - see PRRES20221206 for Footing, sewer, water, under slab inspections. Andrea Sessler 01/30/2024 11:12 AM STOP WORK ORDER generated on 04/25/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 04/25/2024 12:00 AM by username 'Dustin Agcopra'.
01/26/2024
02/09/2024
07/30/2024
08/21/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
TAYLOR@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,198.11 $1,198.11 Paid 02/09/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/24/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 08/02/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Electrical Service Inspection Failed 3/11/2024 3/11/2024 03/11/2024
Miscellaneous Correction
Corrective Action Required
03/11/2024
14 gauge wire in the ceiling next to the HVAC unit needs to be supported
Gas Service Inspection - Residential Passed 3/11/2024 3/11/2024 03/11/2024
All Rough Inspection - Residential Failed 3/11/2024 3/11/2024 03/11/2024
Miscellaneous Correction
Corrective Action Required
03/11/2024
3529 SE Corbin. All rough -Exterior full sheet of OSB does not go to the top and attach to the top plate for portal framing -Anchor bolt in garage north wall is missing 4-12 inches from the end of sole plate -14 gauge wire at ceiling next to HVAC needs to be supported -Fire blocking missing above ceiling in basement rec room east wall -Basement rec room west wall is missing anchor bolts -Top of stair stringers does not bear 1 1/2 inches up against the double 2x10 header -Bottom of the top stair stringer does not bear 1 1/2 inches on entry platform -Top of chase next to kitchen refrigerator need to be fire blocked -Hold down straps are missing at portal CSPF in great room -Truss in bedroom three at south/east corner is not supported -Attic access in utility room does not have 30 inches of head clearance -Top plate in bedroom one is missing an area of 3 1/2 inches at north wall -Truss screw is missing in bedroom one at north wall -Top of chase in master bathroom has to be of solid blocking, not insulation
All Rough Inspection - Residential Failed 3/13/2024 3/13/2024 03/13/2024
Miscellaneous Correction
Resolved
03/13/2024
3529 SE Corbin. All rough -Exterior full sheet of OSB does not go to the top and attach to the top plate for portal framing -Anchor bolt in garage north wall is missing 4-12 inches from the end of sole plate -14 gauge wire at ceiling next to HVAC needs to be supported -Fire blocking missing above ceiling in basement rec room east wall -Basement rec room west wall is missing anchor bolts -Top of stair stringers does not bear 1 1/2 inches up against the double 2x10 header -Bottom of the top stair stringer does not bear 1 1/2 inches on entry platform -Top of chase next to kitchen refrigerator need to be fire blocked -Hold down straps are missing at portal CSPF in great room -Truss in bedroom three at south/east corner is not supported -Attic access in utility room does not have 30 inches of head clearance -Top plate in bedroom one is missing an area of 3 1/2 inches at north wall -Truss screw is missing in bedroom one at north wall -Top of chase in master bathroom has to be of solid blocking, not insulation
Miscellaneous Correction
Corrective Action Required
03/13/2024
3529 SE Corbin. All rough (2) -14 gauge wire at ceiling next to HVAC needs to be supported -Fire blocking missing above ceiling in basement rec room east wall -Attic access in bathroom does not have a attic light installed
Electrical Service Inspection Failed 3/13/2024 3/13/2024 03/13/2024
Miscellaneous Correction
Resolved
03/13/2024
14 gauge wire in the ceiling next to the HVAC unit needs to be supported
Miscellaneous Correction
Corrective Action Required
03/13/2024
2nd inspection -14 gauge wire in the ceiling next to the HVAC unit needs to be supported -New attic access in bathroom does not have a attic light installed
All Rough Inspection - Residential Failed 3/14/2024 3/14/2024 03/14/2024
Miscellaneous Correction
Resolved
03/14/2024
3529 SE Corbin. All rough (2) -14 gauge wire at ceiling next to HVAC needs to be supported -Fire blocking missing above ceiling in basement rec room east wall -Attic access in bathroom does not have a attic light installed
Miscellaneous Correction
Corrective Action Required
03/14/2024
3529 SE Corbin. All rough (3) -Fire blocking missing above ceiling in basement rec room east wall right above where someone sprayed an orange arrow
Electrical Service Inspection Passed 3/14/2024 3/14/2024 03/14/2024
Miscellaneous Correction
Resolved
03/14/2024
2nd inspection -14 gauge wire in the ceiling next to the HVAC unit needs to be supported -New attic access in bathroom does not have a attic light installed
All Rough Inspection - Residential Passed 3/15/2024 3/15/2024 03/15/2024
Miscellaneous Correction
Resolved
03/15/2024
3529 SE Corbin. All rough (3) -Fire blocking missing above ceiling in basement rec room east wall right above where someone sprayed an orange arrow
Sidewalk Inspection Partial 3/25/2024 03/25/2024
Misc
Informational
03/25/2024
3-25-24 Dustin A, Sw is formed and compacted to city specs. Approved to pour
Driveway Inspection Partial 3/25/2024 03/25/2024
Misc
Informational
03/25/2024
3-25-24 Dustin A, DW is formed to city specs and is compacted. Approved to pour
Driveway Inspection Partial 4/1/2024 4/1/2024 04/01/2024
Misc
Informational
03/25/2024
3-25-24 Dustin A, DW is formed to city specs and is compacted. Approved to pour 4-1-24 Dustin A, Dw is poured to city specs. Cannot pass until forms pulled
Sidewalk Inspection Partial 4/1/2024 4/1/2024 04/01/2024
Misc
Informational
03/25/2024
3-25-24 Dustin A, Sw is formed and compacted to city specs. Approved to pour 4-1-24 Dustin A, SW is poured to city specs, cannot pass until forms pulled
Piers/Caissons Inspection - Residential Passed 4/17/2024 4/17/2024 04/17/2024
Driveway Inspection Passed 4/23/2024 4/23/2024 04/23/2024
Misc
Informational
04/01/2024
3-25-24 Dustin A, DW is formed to city specs and is compacted. Approved to pour 4-1-24 Dustin A, Dw is poured to city specs. Cannot pass until forms pulled 4-23-24 Dustin A, Passed
Sidewalk Inspection Passed 4/23/2024 4/23/2024 04/23/2024
Misc
Informational
04/01/2024
3-25-24 Dustin A, Sw is formed and compacted to city specs. Approved to pour 4-1-24 Dustin A, SW is poured to city specs, cannot pass until forms pulled 4-23-24 Dustin A, Passed
Erosion Control Inspection Residential Passed 04/25/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/25/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Plot Plan Inspection Passed 5/20/2024 05/20/2024
Erosion Control Inspection Residential Partial 5/20/2024 05/20/2024
Misc
Corrective Action Required
04/25/2024
OK AT TIME OF INSPECTION
Occupancy Inspection - Codes Residential Failed 5/20/2024 5/20/2024 05/20/2024
Misc
Corrective Action Required
05/20/2024
- Final grading and sod - Provide splash pads 36” away from foundation - Sump discharge to be 36” away from foundation - Seal all exterior penetrations - Fire block around gas line in garage - Fire block above electrical panel in garage - Fire block above garage doors, at gaps in sheet rock - A/v outlet in furnace room be single not duplex and labeled non-gfci or change to gfci - Anti siphon on water main spigot in furnace room has no set screw - Top riser of lower stairs over 7 3/4” and out of 3/8” variance - Provide landing for deck stairs
Erosion Control Inspection Residential Partial 5/24/2024 05/24/2024
Misc
Corrective Action Required
05/20/2024
OK AT TIME OF INSPECTION
Occupancy Inspection - Codes Residential Failed 5/24/2024 5/24/2024 05/24/2024
Misc
Corrective Action Required
05/20/2024
- Final grading and sod - Provide splash pads 36” away from foundation - Sump discharge to be 36” away from foundation
Occupancy Inspection - Codes Residential Ready for Temp CO 5/24/2024 05/24/2024
Misc
Corrective Action Required
05/24/2024
- Final grading and sod - Provide splash pads 36” away from foundation - Sump discharge to be 36” away from foundation
Erosion Control Inspection Residential Passed 6/25/2024 06/25/2024
Misc
Corrective Action Required
05/24/2024
OK AT TIME OF INSPECTION
Occupancy Inspection - Codes Residential Not Ready 6/28/2024 06/28/2024
Misc
Resolved
06/28/2024
- Final grading and sod - Provide splash pads 36” away from foundation - Sump discharge to be 36” away from foundation
Miscellaneous Correction
Corrective Action Required
06/28/2024
- Final grading and sod - Provide splash pads 36” away from foundation - Sump discharge to be 36” away from foundation - Obtain irrigation permit No response from letter sent 06/25/2924 to builder for TCO extension -Not Ready-
Erosion Control Inspection Residential Failed 7/1/2024 07/01/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/01/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Add erosion control at the street and clean mud and debris from the sidewalk, driveway and street
Occupancy Inspection - Codes Residential Failed 7/26/2024 07/26/2024
Miscellaneous Correction
Corrective Action Required
06/28/2024
- Final grading and sod - Provide splash pads 36” away from foundation - Sump discharge to be 36” away from foundation - Obtain irrigation permit No response from letter sent 06/25/2924 to builder for TCO extension -Not Ready-
Miscellaneous Correction
Corrective Action Required
07/26/2024
10 day NOV letter has been issued
Occupancy Inspection - Codes Residential Full C of O 8/21/2024 08/21/2024
Miscellaneous Correction
Resolved
08/21/2024
- Final grading and sod - Provide splash pads 36” away from foundation - Sump discharge to be 36” away from foundation - Obtain irrigation permit No response from letter sent 06/25/2924 to builder for TCO extension -Not Ready-
Miscellaneous Correction
Resolved
08/21/2024
10 day NOV letter has been issued
Erosion Control Inspection Residential Passed 8/21/2024 08/21/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
08/21/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Add erosion control at the street and clean mud and debris from the sidewalk, driveway and street
Documents & Images
Date Uploaded File Type Document Name
01/26/2024 CB #145 - Permit Application
02/01/2024 Permit Codes Residential Plan Review
02/06/2024 Approved Plans APPROVED TRUSS PACKAGE
02/06/2024 Approved Plans APPROVED TRUSS LAYOUT
02/07/2024 Approved Plans APPROVED PLANS
02/07/2024 Plot Plan APPROVED PLOT PLAN
02/09/2024 COBEY CREEK 145 - FND CLARIFICATION - 240209
02/09/2024 Permit Codes Residential Plan Review
02/09/2024 Permit DS Building Permit
02/09/2024 Receipt Receipt for transaction:2024-000776
03/11/2024 Letter INSPECTION SUMMARY
03/11/2024 Letter INSPECTION SUMMARY
03/11/2024 Letter INSPECTION SUMMARY
03/13/2024 Letter INSPECTION SUMMARY
03/13/2024 Letter INSPECTION SUMMARY
03/14/2024 Letter INSPECTION SUMMARY
03/14/2024 Letter INSPECTION SUMMARY
03/15/2024 Letter INSPECTION SUMMARY
03/25/2024 Letter INSPECTION SUMMARY
03/25/2024 Letter INSPECTION SUMMARY
04/01/2024 Letter INSPECTION SUMMARY
04/01/2024 Letter INSPECTION SUMMARY
04/17/2024 Letter INSPECTION SUMMARY
04/23/2024 Letter INSPECTION SUMMARY
04/23/2024 Letter INSPECTION SUMMARY
04/25/2024 Letter Stop Work Order
04/25/2024 Letter Stop Work Order
04/25/2024 Letter INSPECTION SUMMARY
05/20/2024 Letter INSPECTION SUMMARY
05/20/2024 Letter INSPECTION SUMMARY
05/20/2024 Letter INSPECTION SUMMARY
05/20/2024 Letter INSPECTION SUMMARY
05/24/2024 Letter INSPECTION SUMMARY
05/24/2024 Letter INSPECTION SUMMARY
05/24/2024 Certificate/License Codes Temporary Certificate of Occupancy
05/24/2024 Receipt Receipt for transaction:2024-003950
05/30/2024 Plot Plan APPROVED AS BUILT PLOT PLAN
06/25/2024 Letter INSPECTION SUMMARY
06/28/2024 Letter INSPECTION SUMMARY
07/01/2024 Letter INSPECTION SUMMARY
07/26/2024 Letter Codes 10 Day Letter
07/26/2024 Letter INSPECTION SUMMARY
08/02/2024 Application Form CB #145 - TCO Extension Request Form
08/02/2024 Receipt Receipt for transaction:2024-006502
08/21/2024 Letter Field Certificate of Occupancy
08/21/2024 Letter Codes Final Certificate of Occupancy
08/21/2024 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home