Permit Application Status

PRRES20240001


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20240001
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. COVERED PATIO.
01/01/2024
03/05/2024
07/21/2024
03/27/2025
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
5 STAR HEATING & COOLING, Address:211 NW 12TH, Phone:(816) 517-3341  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
WALKERCUSTOMHOMESKC@GMAIL.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 03/05/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 03/05/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 03/05/2024
9110078-Valuation Fee New Single Family $2,301.00 $2,301.00 Paid 03/05/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 02/27/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/27/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 4/11/2024 4/11/2024 04/11/2024
Footing Inspection - Residential Passed 04/11/2024
Informational
04/11/2024
FOOTING APPROVED BY ENGINEER
Sewer Service Inspection - R Passed 4/30/2024 04/30/2024
All Rough Inspection - Residential Failed 8/7/2024 8/7/2024 08/07/2024
Misc
Corrective Action Required
08/07/2024
-Anchor bolts in garage are not in middle 1/3 of base plate -Address surface mounted electrical cables at upper southeast corner of garage -Missing fire blocking at top of chase in powder room off of garage -Vent hose at powder room not installed -Missing joist hanger at north east corner of kitchen pantry -Seal all exterior wall penetrations
All Rough Inspection - Residential Failed 8/15/2024 8/15/2024 08/15/2024
Misc
Corrective Action Required
08/07/2024
-Vent hose at powder room not installed **Protect fan duct from damage with min 16 gauge strike plates **OK TO INSULATE
All Rough Inspection - Residential Failed 8/22/2024 8/22/2024 08/22/2024
Misc
Corrective Action Required
08/15/2024
-Vent hose at powder room not installed **Protect fan duct from damage with min 16 gauge strike plates; flex duct is limited to max 14 ft run **OK TO INSULATE
All Rough Inspection - Residential Passed 8/27/2024 8/27/2024 08/27/2024
Misc
Resolved
08/27/2024
-Vent hose at powder room not installed **Protect fan duct from damage with min 16 gauge strike plates; flex duct is limited to max 14 ft run **OK TO INSULATE
Electrical Service Inspection Passed 9/18/2024 09/18/2024
Gas Service Inspection - Residential Passed 9/18/2024 09/18/2024
Driveway Inspection Partial 10/10/2024 10/10/2024 10/10/2024
Misc
Informational
10/10/2024
10-10-24 NS Site visited and it appears that driveway meets city standards but they also need to pour the sidewalk.
Erosion Control Inspection Residential Failed 1/30/2025 01/30/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/30/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - SILT FENCE DOWN AT FRONT OF LOT. PROTECT FRONT OF LOT.
Occupancy Inspection - Codes Residential Failed 1/30/2025 1/30/2025 01/30/2025
Misc
Corrective Action Required
01/30/2025
INSPECTION DENIDE EROSION CONTROL NOT IN COMPLIANCE
Erosion Control Inspection Residential Failed 2/3/2025 02/03/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/30/2025
-EXTEND EROSION CONTROL ALONG FRONT STREET TO SIDEWALK
Occupancy Inspection - Codes Residential Failed 2/3/2025 2/3/2025 02/03/2025
Misc
Corrective Action Required
01/30/2025
-Driveway and sidewalk not approved on record -Final grade, sod, downspout and sump pump extension -Seal exterior wall hole at sewer pump control, seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc -Provide sewer tracer wire port at grade -Provide guardrail at open side of front stoop more than 30” above final grade, as measure from 36” out from edge down to grade -Luminaire inside master closet shall be completely enclosed lamp type; luminaire inside upper floor closet shall be completely enclosed lamp type -Pendant light cannot be located within master bathroom tub zone -Maximum stair riser height shall be no more than 3/8” -Glazing in the pantry door shall be safety tempered glazing -Support furnace intake&exhaust pipes every 5 ft
Driveway Inspection Passed 2/4/2025 02/04/2025
Misc
Informational
10/10/2024
10-10-24 NS Site visited and it appears that driveway meets city standards but they also need to pour the sidewalk. 2-4-25 NS Site visited and it appears driveway meets city’s standard no sidewalk passed
Occupancy Inspection - Codes Residential Failed 2/11/2025 2/11/2025 02/11/2025
Misc
Corrective Action Required
02/03/2025
-Provide sewer tracer wire port at grade -Provide guardrail at open side of front stoop more than 30” above final grade, as measure from 36” out from edge down to grade -Glazing in the pantry door shall be safety tempered glazing
Erosion Control Inspection Residential Passed 2/27/2025 02/27/2025
DCM2 ESC DEFICIENT INSTALLATION
Resolved
02/27/2025
-EXTEND EROSION CONTROL ALONG FRONT STREET TO SIDEWALK
Occupancy Inspection - Codes Residential Ready for Temp CO 2/27/2025 2/27/2025 02/27/2025
Misc
Corrective Action Required
02/11/2025
-Provide sewer tracer wire port at grade -Sod and downspout splashblocks
Occupancy Inspection - Codes Residential Ready for Temp CO 3/21/2025 03/21/2025
Misc
Corrective Action Required
02/27/2025
-Provide sewer tracer wire port at grade -Sod and downspout splashblocks
Occupancy Inspection - Codes Residential Full C of O 3/27/2025 3/27/2025 03/27/2025
Misc
Resolved
03/27/2025
-Provide sewer tracer wire port at grade -Sod and downspout splashblocks
Documents & Images
Date Uploaded File Type Document Name
01/01/2024 2604 Woodland Oak City Signed Docs
01/23/2024 Permit Codes Residential Plan Review
02/23/2024 Approved Plans APPROVED PLANS
02/23/2024 Plot Plan APPROVED PLOT PLAN
02/23/2024 Permit Codes Residential Plan Review
03/05/2024 Permit DS Building Permit
03/05/2024 Receipt Receipt for transaction:2024-001328
03/22/2024 3RD Party Insp Report Wilmoth 2604 NE Woodland Oak Dr LSMO Footing Inspection Report 3-21-24
04/11/2024 Letter INSPECTION SUMMARY
04/11/2024 Letter INSPECTION SUMMARY
04/30/2024 Letter INSPECTION SUMMARY
05/08/2024 3RD Party Insp Report THIRD PARTY PIER REPORT
08/07/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter INSPECTION SUMMARY
08/22/2024 Letter INSPECTION SUMMARY
08/27/2024 Letter INSPECTION SUMMARY
09/18/2024 Letter INSPECTION SUMMARY
09/18/2024 Letter INSPECTION SUMMARY
01/30/2025 Letter INSPECTION SUMMARY
01/30/2025 Letter INSPECTION SUMMARY
02/03/2025 Letter INSPECTION SUMMARY
02/03/2025 Letter INSPECTION SUMMARY
02/03/2025 Letter INSPECTION SUMMARY
02/11/2025 Letter INSPECTION SUMMARY
02/27/2025 Letter INSPECTION SUMMARY
02/27/2025 Letter INSPECTION SUMMARY
02/27/2025 Letter INSPECTION SUMMARY
02/27/2025 Certificate/License Codes Temporary Certificate of Occupancy
02/27/2025 Receipt Receipt for transaction:2025-001176
03/20/2025 Application Form Schedule for Completion
03/20/2025 Application Form 2604 NE Woodland Oak Dr Substantial Completion and Temporary Occupancy Extension Request
03/27/2025 Letter Codes Final Certificate of Occupancy
03/27/2025 Letter Field Certificate of Occupancy
03/27/2025 Letter INSPECTION SUMMARY
03/27/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/27/2025 Receipt Receipt for transaction:2025-001849
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home