Summary
PRRES20236429
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
12/08/2023
12/14/2023
08/23/2024
Locations
Contacts
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST, Phone:(816) 470-0074  
Erin Skinner, Address:1314 SW Market Street  
PERMITTING@JFECONSTRUCTION.COM  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 12/14/2023
Right of Way Permit Fee $85.00 $85.00 Paid 12/14/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 12/14/2023
Water Tap Fee $3,760.00 $3,760.00 Paid 12/14/2023
Water Meter Fee $680.46 $680.46 Paid 12/14/2023
Valuation Fee New Single Family $1,640.46 $1,640.46 Paid 12/14/2023
$0.00 $0.00 $0.00 N/A
$0.00 $0.00 $0.00 N/A
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 02/06/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/06/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -MAINTAIN EROSION CONTROL AT FRONT OF LOT
Footing Inspection - Residential Passed 2/6/2024 2/6/2024 02/06/2024
Misc
Informational
02/06/2024
Footing approved by David Ainsworth on 1/30/24
Water Service Inspection - R Partial 2/20/2024 2/20/2024 02/20/2024
Sewer Service Inspection - R Passed 2/20/2024 2/20/2024 02/20/2024
Water Service Inspection - R Passed 2/21/2024 02/21/2024
Underslab Electrical Inspection - Residential Passed 3/7/2024 3/7/2024 03/07/2024
Underslab Plumbing Inspection - Residential Passed 3/7/2024 3/7/2024 03/07/2024
Electrical Service Inspection Passed 5/14/2024 5/14/2024 05/14/2024
Gas Service Inspection - Residential Passed 5/14/2024 5/14/2024 05/14/2024
All Rough Inspection - Residential Failed 5/14/2024 5/14/2024 05/14/2024
Misc
Corrective Action Required
05/14/2024
-Replace all over notched studs at PFH or provide engineered correction -Tighten nuts at PFH anchor bolts -Provide lateral restraint at ceiling joists above load bearing walls and beam -Headers at load bearing walls to have min (2) 2x4 jack studs at mud room/ garage entry, at basement door and sliding glass doors -Missing (4) 2x6 studs under LVL at dining/living room -Fireblock ceiling line at entry closet-see switch location, foam is inadequate in this location -Nail corner studs at bedroom 2 -Connect and support Hips and ridges per note 15 on GA5 and details on S2 -Fireblock stair landing line at stud space in basement -Load bearing stud drilled closer than 5/8” to face of stud at wet bar -Underslab wiring at wet bar must be rated for wet location -Install second anchor bolt at plate left of egress window bed 4 -Install anchor bolt at right side of dog door referenced in plans -Provide engineered connection for discontinuous posts at deck -Nail braced wall EC 3 at single car garage
All Rough Inspection - Residential Passed 5/21/2024 5/21/2024 05/21/2024
Misc
Resolved
05/21/2024
-Replace all over notched studs at PFH or provide engineered correction -Tighten nuts at PFH anchor bolts -Provide lateral restraint at ceiling joists above load bearing walls and beam -Headers at load bearing walls to have min (2) 2x4 jack studs at mud room/ garage entry, at basement door and sliding glass doors -Missing (4) 2x6 studs under LVL at dining/living room -Fireblock ceiling line at entry closet-see switch location, foam is inadequate in this location -Nail corner studs at bedroom 2 -Connect and support Hips and ridges per note 15 on GA5 and details on S2 -Fireblock stair landing line at stud space in basement -Load bearing stud drilled closer than 5/8” to face of stud at wet bar -Underslab wiring at wet bar must be rated for wet location -Install second anchor bolt at plate left of egress window bed 4 -Install anchor bolt at right side of dog door referenced in plans -Provide engineered connection for discontinuous posts at deck -Nail braced wall EC 3 at single car garage
Driveway Inspection Passed 6/13/2024 6/13/2024 06/14/2024
Misc
Informational
06/14/2024
6-14-24 Dustin A, DW is poured to city specs, Passed
Plot Plan Inspection Passed 7/30/2024 07/30/2024
Occupancy Inspection - Codes Residential Failed 8/14/2024 8/14/2024 08/14/2024
Miscellaneous Correction
Corrective Action Required
08/14/2024
2210 NW Killarney. Occupancy -Install security screws in hinges at walkout basement exterior door -Secure water sprinkler control valve in basement Sod and exterior splash pads are not installed
Erosion Control Inspection Residential Partial 8/14/2024 08/14/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
08/14/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -MAINTAIN EROSION CONTROL AT FRONT OF LOT
Miscellaneous Correction
Informational
08/14/2024
Erosion control measures are in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Full C of O 8/23/2024 8/23/2024 08/23/2024
Miscellaneous Correction
Resolved
08/23/2024
2210 NW Killarney. Occupancy -Install security screws in hinges at walkout basement exterior door -Secure water sprinkler control valve in basement Sod and exterior splash pads are not installed
Documents & Images
Date Uploaded File Type Document Name
12/08/2023 WR-185
12/08/2023 WR-185_2210 NW KILLARNEY LN_PERMIT_12-7-23
12/08/2023 Application Form WR185 - Permit App
12/08/2023 WR185 - Tax App
12/14/2023 Permit Codes Residential Plan Review
12/14/2023 Approved Plans APPROVED PLANS
12/14/2023 Plot Plan approved plot plan
12/14/2023 Permit DS Building Permit
12/14/2023 Receipt Receipt for transaction:2023-009091
01/08/2024 WR-185_2210 NW KILLARNEY LN_PIER PLAN_1-4-24
01/08/2024 Approved Plans APPROVED BASEMENT PIER PLAN
02/05/2024 Wilmoth 2210 NW Killarney Ln LSMO Footing Inspection Report 1-30-24
02/06/2024 Letter INSPECTION SUMMARY
02/06/2024 Letter INSPECTION SUMMARY
02/20/2024 Letter INSPECTION SUMMARY
02/20/2024 Letter INSPECTION SUMMARY
02/21/2024 Letter INSPECTION SUMMARY
03/07/2024 Letter INSPECTION SUMMARY
03/07/2024 Letter INSPECTION SUMMARY
03/07/2024 Letter INSPECTION SUMMARY
03/12/2024 2210 nw killarney ln_all slab insp_2024-03-11
03/21/2024 3rd Party Permit/Approval wr 185 - 2210 nw killarney ln_pier insp_2024-01-29
05/14/2024 Letter INSPECTION SUMMARY
05/14/2024 Letter INSPECTION SUMMARY
05/14/2024 Letter INSPECTION SUMMARY
05/20/2024 3RD Party Insp Report ENGINEER FRAMING REPORT
05/21/2024 Letter INSPECTION SUMMARY
06/14/2024 Letter INSPECTION SUMMARY
07/29/2024 Plot Plan approved as graded plot plan
07/30/2024 Letter INSPECTION SUMMARY
08/14/2024 Letter INSPECTION SUMMARY
08/14/2024 Letter INSPECTION SUMMARY
08/23/2024 Letter Field Certificate of Occupancy
08/23/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home