Permit Application Status

PRRES20233917


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20233917
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED AND UNCOVERED DECK
08/10/2023
09/07/2023
02/13/2024
06/14/2024
Locations
Contacts
TRUMARK HOMES INC, Address:508 NW MANOR DR  
MARK A YANCIK, Address:508 nw manor dr  
TRUMARKHOMES.MARK@GMAIL.COM  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 09/07/2023
Right of Way Permit Fee $85.00 $85.00 Paid 09/07/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 09/07/2023
Water Tap Fee $3,760.00 $3,760.00 Paid 09/07/2023
Water Meter Fee $680.46 $680.46 Paid 09/07/2023
Valuation Fee New Single Family $1,764.81 $1,764.81 Paid 09/07/2023
Not Ready Inspection Fee $75.00 $75.00 Paid 03/27/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 03/27/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 03/27/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 04/26/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 05/16/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 9/21/2023 9/21/2023 09/21/2023
Footing Inspection - Residential Passed 10/10/2023 10/10/2023
All Rough Inspection - Residential Passed 10/10/2023 10/10/2023 10/10/2023
All Rough Inspection - Residential Failed 10/10/2023 10/11/2023
Misc
Corrective Action Required
10/11/2023
garage portal only
Sewer Service Inspection - R Passed 11/10/2023 11/10/2023
Water Service Inspection - R Passed 11/15/2023 11/15/2023 11/15/2023
Electrical Service Inspection Failed 11/21/2023 11/21/2023
Misc
Corrective Action Required
11/21/2023
-Provide City approved, stamped plans for inspection
Gas Service Inspection - Residential Failed 11/21/2023 11/21/2023
Misc
Corrective Action Required
11/21/2023
-Provide City approved, stamped plans for inspection
All Rough Inspection - Residential Not Ready 11/21/2023 11/21/2023
Misc
Informational
11/21/2023
11/11/23 garage portal only
Misc
Corrective Action Required
11/21/2023
11/21/23 **Not ready, complete all of the following before re scheduling: -Provide City approved, stamped plans for inspection -Sister over notched studs cut for anchor bolts in garage -Nail exterior corners and intersecting walls 12” oc -Seal gaps in fireblocking at top of HVAC chase in garage -Solid block between joists above load bearing walls and beams to prevent lateral rotation -Strap top plates at garage/entry where walls not connected at top plate -Fireblock top of fur out wall in laundry -Fireblock top of fireplace wall -Nail overlapping ceiling joists per code -Nail rafter to ceiling joists per code-unable to verify due to insulation -Nail rafters to top plate per code-unable to verify due to insulation
All Rough Inspection - Residential Not Ready 11/28/2023 11/21/2023
Misc
Informational
11/21/2023
11/11/23 garage portal only
Misc
Corrective Action Required
11/21/2023
11/21/23 **Not ready, complete all of the following before re scheduling: -Provide City approved, stamped plans for inspection -Sister over notched studs cut for anchor bolts in garage -Nail exterior corners and intersecting walls 12” oc -Seal gaps in fireblocking at top of HVAC chase in garage -Solid block between joists above load bearing walls and beams to prevent lateral rotation -Strap top plates at garage/entry where walls not connected at top plate -Fireblock top of fur out wall in laundry -Fireblock top of fireplace wall -Nail overlapping ceiling joists per code -Nail rafter to ceiling joists per code-unable to verify due to insulation -Nail rafters to top plate per code-unable to verify due to insulation **INSPECTION INCOMPLETE
Gas Service Inspection - Residential Passed 11/22/2023 11/22/2023 11/22/2023
Misc
Resolved
11/22/2023
-Provide City approved, stamped plans for inspection
Electrical Service Inspection Passed 11/22/2023 11/22/2023 11/22/2023
Misc
Resolved
11/22/2023
-Provide City approved, stamped plans for inspection
All Rough Inspection - Residential Not Ready 11/22/2023 11/22/2023 11/22/2023
Misc
Informational
11/21/2023
11/11/23 garage portal only
Misc
Corrective Action Required
11/21/2023
11/21/23 **Not ready -provide City approved, stamped plans for inspection -Provide bocca plate at top plate in laundry furout wall -Missing nails at joist hangers in Kitchen -Complete covered deck -Install egress window -Seal gaps in top of verticle fireblocking in rec room -Sister all over notched studs at exterior basement walls -Fireblock wall space to stair landing -Provide anchor bolts within 12" of plate breaks in basement **INSPECTION INCOMPLETE
Erosion Control Inspection Residential Failed 11/29/2023
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
11/29/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -MAINTAIN GRAVEL FILTER WITH MIN 6" LIFT OF 3/4" GRAVEL
All Rough Inspection - Residential Passed 11/29/2023 11/29/2023 11/29/2023
Misc
Resolved
11/29/2023
11/11/23 garage portal only
Misc
Resolved
11/29/2023
11/21/23 **Not ready -provide City approved, stamped plans for inspection -Provide bocca plate at top plate in laundry furout wall -Missing nails at joist hangers in Kitchen -Complete covered deck -Install egress window -Seal gaps in top of verticle fireblocking in rec room -Sister all over notched studs at exterior basement walls -Fireblock wall space to stair landing -Provide anchor bolts within 12" of plate breaks in basement **INSPECTION INCOMPLETE
Driveway Inspection Partial 12/20/2023 12/20/2023
Misc
Informational
12/20/2023
Driveway passed pre-inspection forms and materials.
Driveway Inspection Passed 12/21/2023 12/21/2023 12/29/2023
Misc
Informational
12/20/2023
Driveway passed pre-inspection forms and materials.
Misc
Informational
12/29/2023
Driveway passed final inspection. 12/29/23 JMJ
Occupancy Inspection - Codes Residential Failed 3/21/2024 3/21/2024 03/21/2024
Misc
Corrective Action Required
11/29/2023
-Complete final grade, sod, splash blocks, foundation drainage -Garage door must self close and latch -Secure handrail at garage -Provide hammer arrestors at laundry -Handrainl to basement must maintain 1.5" clearance -Label non GFCI receptacle at sump pump -Provide security screws at front and basement door per LS CH 7 security code -Provide secondary lock at sliding glass door per LS CH 7 Security code -Install missing joist hangers at 2 end joists of deck -Flood light at back must be a sealed type fixture or not readily accessible
Erosion Control Inspection Residential Partial 03/21/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
11/29/2023
Erosion control in compliance at time of inspection -Maintain EC methods until sod is in place
Occupancy Inspection - Codes Residential Ready for Temp CO 3/27/2024 3/27/2024 03/27/2024
Misc
Corrective Action Required
03/21/2024
-Complete final grade, sod, splash blocks, foundation drainage -Install missing joist hangers at 2 end joists of deck
Erosion Control Inspection Residential Passed 4/19/2024 04/19/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/21/2024
Erosion control in compliance at time of inspection -Maintain EC methods until sod is in place
Occupancy Inspection - Codes Residential Failed 4/19/2024 4/19/2024 04/19/2024
Misc
Resolved
04/19/2024
Misc
Corrective Action Required
04/19/2024
-Address large sink hole in front yard
Plot Plan Inspection Failed 4/19/2024 04/19/2024
Misc
Corrective Action Required
04/19/2024
-Address large sink hole in front yard
Occupancy Inspection - Codes Residential Ready for Temp CO 4/26/2024 04/26/2024
Misc
Corrective Action Required
04/19/2024
-Address large sink hole in front yard
Occupancy Inspection - Codes Residential Ready for Temp CO 05/16/2024
Misc
Corrective Action Required
04/26/2024
-Address large sink hole in front yard
Plot Plan Inspection Passed 06/14/2024
Misc
Resolved
06/14/2024
-Address large sink hole in front yard
Occupancy Inspection - Codes Residential Full C of O 6/14/2024 6/14/2024 06/14/2024
Misc
Resolved
06/14/2024
-Address large sink hole in front yard
Documents & Images
Date Uploaded File Type Document Name
08/10/2023 NextDocument 783 2230 KILLARNEY LN PERMIT APPLICATION 189
08/10/2023 NextDocument 784 2230 KILLARNEY LN EXCISE APPLICATION 189
08/10/2023 NextDocument 779 LOT 189 WOODSIDE PLOT PLAN 2230 KILLARNEY LN
08/10/2023 2230 NW Killarney Ln LSMO Woodside Reserve Lot 189 Dwgs Re Stamped Submittal 7-31-23
08/10/2023 Permit Codes Residential Plan Review
08/10/2023 Approved Plans approved plans
08/16/2023 NextDocument 812 REVISED PLOT PLAN LOT 189 WOODSIDE
08/17/2023 Permit Codes Residential Plan Review
08/17/2023 NextDocument 832 LOT 189 REVISED PLOT PLAN
08/17/2023 Plot Plan approved plot plan
08/17/2023 Permit Codes Residential Plan Review
09/07/2023 Permit DS Building Permit
09/07/2023 Receipt Receipt for transaction:2023-006883
09/15/2023 M L Crose 2230 NW Killarney LN LSMO Woodside Ridge Lot 189 Footing Inspection Report 9-7-23
09/21/2023 Letter INSPECTION SUMMARY
10/10/2023 Letter INSPECTION SUMMARY
10/10/2023 Letter INSPECTION SUMMARY
11/10/2023 Letter INSPECTION SUMMARY
11/10/2023 Letter INSPECTION SUMMARY
11/15/2023 Letter INSPECTION SUMMARY
11/21/2023 Letter INSPECTION SUMMARY
11/21/2023 Letter INSPECTION SUMMARY
11/21/2023 Letter INSPECTION SUMMARY
11/21/2023 Letter INSPECTION SUMMARY
11/22/2023 Letter INSPECTION SUMMARY
11/22/2023 Letter INSPECTION SUMMARY
11/22/2023 Letter INSPECTION SUMMARY
11/29/2023 Letter INSPECTION SUMMARY
11/29/2023 Letter INSPECTION SUMMARY
12/20/2023 Letter INSPECTION SUMMARY
12/29/2023 Letter INSPECTION SUMMARY
03/21/2024 Letter INSPECTION SUMMARY
03/21/2024 Letter INSPECTION SUMMARY
03/27/2024 Certificate/License Codes Temporary Certificate of Occupancy
03/27/2024 Receipt Receipt for transaction:2024-001933
04/19/2024 Letter INSPECTION SUMMARY
04/19/2024 Letter INSPECTION SUMMARY
04/19/2024 Letter INSPECTION SUMMARY
04/26/2024 Application Form EXTENSION FORM
04/26/2024 Certificate/License Codes Temporary Certificate of Occupancy
04/26/2024 Receipt Receipt for transaction:2024-002680
05/16/2024 Application Form TCOExtension Request Form
05/16/2024 Certificate/License Codes Temporary Certificate of Occupancy
05/16/2024 Receipt Receipt for transaction:2024-003549
06/14/2024 Letter INSPECTION SUMMARY
06/14/2024 Letter Codes Final Certificate of Occupancy
06/14/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home