Summary
PRRES20233310
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW DUPLEX - UNFINISHED BASEMENT - ROOF TRUSSES -
07/10/2023
07/24/2023
04/24/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
SAVANNA@SUMMITHOMESKC.COM  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Duplex $3,190.50 $3,190.50 Paid 07/24/2023
Sanitary Sewer Development Fee $4,318.00 $4,318.00 Paid 07/24/2023
Right of Way Permit Fee $85.00 $85.00 Paid 07/24/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 07/24/2023
Water Tap Fee $7,520.00 $7,520.00 Paid 07/24/2023
Water Meter Fee $1,360.92 $1,360.92 Paid 07/24/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 12/14/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 03/01/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 04/23/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/3/2023 08/03/2023
Miscellaneous Correction
Informational
08/03/2023
Footing passed by a third party
Sewer Service Inspection - R Failed 8/18/2023 08/18/2023
Miscellaneous Correction
Informational
08/18/2023
3743 sewer passed only. This is a partial and 3745 will be called in for inspection at a later date.
Sewer Service Inspection - R Passed 8/21/2023 (1:15) 8/21/2023 08/21/2023
Miscellaneous Correction
Informational
08/18/2023
3743 sewer passed only. This is a partial and 3745 will be called in for inspection at a later date.
Underslab Plumbing Inspection - Residential Passed 8/22/2023 8/22/2023 08/22/2023
Erosion Control Inspection Residential Failed 8/25/2023 08/25/2023
Miscellaneous Correction
Corrective Action Required
08/25/2023
Full property erosion control is not in place. Erosion control must be maintained until occupancy
Erosion Control Inspection Residential Failed 8/29/2023 08/29/2023
Miscellaneous Correction
Corrective Action Required
08/25/2023
Full property erosion control is not in place. Erosion control must be maintained until occupancy
Miscellaneous Correction
Corrective Action Required
08/29/2023
Full erosion control is still not in place. Erosion must be installed and maintained until full CO. Install erosion control and remove dirt and gravel from the streets. This includes the lots adjacent to this property. No inspections will be completed until proper erosion control is in place. 08/29/2023 KBEARD
All Rough Inspection - Residential Failed 9/28/2023 9/28/2023 09/28/2023
Miscellaneous Correction
Informational
09/28/2023
Garage portal CSPF passed for both units. This is a partial all rough only.
All Rough Inspection - Residential Failed 10/3/2023 10/03/2023
Miscellaneous Correction
Informational
09/28/2023
Garage portal CSPF passed for both units. This is a partial all rough only.
Miscellaneous Correction
Corrective Action Required
10/03/2023
3743 Garage anchor bolts need to be located in the middle 1/3 of bottom plate which includes within 4 inches from the end Stud shoe needs to be installed in the powder bathroom at the 1 1/4 drain pipe Fire blocking is missing throughout Fire decking is cut around boards above utility and bedroom 1 Remove anti siphon screw Electrical panel is not grounded using the UFER 3745 Top plate in great room has a break in it less than 4 feet from the corner Fire decking is cut around boards above utility and bedroom 1 Anti siphon valve is missing UFER is not utilized for grounding of the electrical panel
Rated Assembly Inspection Failed 10/3/2023 10/3/2023 10/03/2023
Miscellaneous Correction
Corrective Action Required
10/03/2023
Fire decking is cut through within 4 feet of the rated assembly wall
Erosion Control Inspection Residential Failed 10/3/2023 10/03/2023
Miscellaneous Correction
Corrective Action Required
08/29/2023
Full property erosion control is not in place. Erosion control must be maintained until occupancy
Miscellaneous Correction
Corrective Action Required
08/29/2023
Full erosion control is still not in place. Erosion must be installed and maintained until full CO. Install erosion control and remove dirt and gravel from the streets. This includes the lots adjacent to this property. No inspections will be completed until proper erosion control is in place. 08/29/2023 KBEARD
Miscellaneous Correction
Corrective Action Required
10/03/2023
Replace erosion control where missing or damaged along Osage Dr
Gas Service Inspection - Residential Passed 10/3/2023 10/3/2023 10/03/2023
Electrical Service Inspection Failed 10/3/2023 10/3/2023 10/03/2023
Miscellaneous Correction
Corrective Action Required
10/03/2023
Electrical panels in both units are not grounded using the UFER’s
Rated Assembly Inspection Passed 10/4/2023 10/4/2023 10/04/2023
Miscellaneous Correction
Resolved
10/04/2023
Fire decking is cut through within 4 feet of the rated assembly wall
All Rough Inspection - Residential Passed 10/4/2023 10/4/2023 10/04/2023
Miscellaneous Correction
Informational
10/03/2023
Garage portal CSPF passed for both units. This is a partial all rough only.
Miscellaneous Correction
Resolved
10/04/2023
3743 Garage anchor bolts need to be located in the middle 1/3 of bottom plate which includes within 4 inches from the end Stud shoe needs to be installed in the powder bathroom at the 1 1/4 drain pipe Fire blocking is missing throughout Fire decking is cut around boards above utility and bedroom 1 Remove anti siphon screw Electrical panel is not grounded using the UFER 3745 Top plate in great room has a break in it less than 4 feet from the corner Fire decking is cut around boards above utility and bedroom 1 Anti siphon valve is missing UFER is not utilized for grounding of the electrical panel
Electrical Service Inspection Passed 10/9/2023 10/9/2023 10/09/2023
Miscellaneous Correction
Resolved
10/09/2023
Electrical panels in both units are not grounded using the UFER’s
Driveway Inspection Partial 11/1/2023 11/1/2023 11/01/2023
Misc
Informational
11/01/2023
11-1-23 Dustin A, DW is formed , aggregate is compacted. Depth is in compliance. Will need to maintain 2 % for A.D.A compliance through approach. Approved to pour
Sidewalk Inspection Partial 11/1/2023 11/1/2023 11/01/2023
Misc
Informational
11/01/2023
11-1-23 Dustin A. SW is formed and aggregate is compacted. Slopes are in compliance . It is attached to a A.D.A that is not in compliance but was approved by R.H and Bob Burns . Approved to pour.
Driveway Inspection Passed 11/8/2023 11/8/2023 11/08/2023
Misc
Informational
11/01/2023
11-1-23 Dustin A, DW is formed , aggregate is compacted. Depth is in compliance. Will need to maintain 2 % for A.D.A compliance through approach. Approved to pour 11-8-23 Dustin A, Dw poured, Slopes are in compliance . Forms are pulled. Passed
Sidewalk Inspection Partial 11/8/2023 11/8/2023 11/08/2023
Misc
Informational
11/01/2023
11-1-23 Dustin A. SW on garage side is formed and aggregate is compacted. Slopes are in compliance . Approved to pour. 11-8-23 Sw on south side of house is formed and aggregate is compacted . slopes are in compliance . Approved to pour
Sidewalk Inspection Partial 11/15/2023 11/15/2023 11/14/2023
Misc
Informational
11/08/2023
11-1-23 Dustin A. SW on garage side is formed and aggregate is compacted. Slopes are in compliance . Approved to pour. 11-8-23 Sw on south side of house is formed and aggregate is compacted . slopes are in compliance . Approved to pour 11-14-23 Dustin A, Conditions have not changed
Sidewalk Inspection Passed 11/28/2023 11/28/2023 11/28/2023
Misc
Informational
11/14/2023
11-1-23 Dustin A. SW on garage side is formed and aggregate is compacted. Slopes are in compliance . Approved to pour. 11-8-23 Sw on south side of house is formed and aggregate is compacted . slopes are in compliance . Approved to pour 11-14-23 Dustin A, Conditions have not changed 11-28-23 Dustin A, Rest of sw is poured and forms are pulled. Slopes are in compliance. Passed.
Occupancy Inspection - Codes Residential Failed 12/7/2023 12/7/2023 12/07/2023
Miscellaneous Correction
Corrective Action Required
12/07/2023
3743 and 3745 SW Clayton TCO 3743 front porch steps are required to have a hand rail with four or more steps Seal all ceiling penetrations in garage Front door is hard to seal shut Back porch lamp is attached using interior sheet rock screws Electrical outlet under kitchen could not be test because of lack of clearance to the garbage disposal First to second riser from entrance has over the allowable 3/8 inch height difference Attic access door is not secured Smoke detectors my be faulty. Check alarm time Basement handrail is closer than the allowable 1 1/2 inches to the wall towards the bottom of the stairs Electrical panel is missing GFCI receptacle Exterior of house was not inspected 3745 front porch has 4 steps and requires a hand rail Back porch security lamp is fastened using interior sheet rock screws Electrical panel does not have attached GFCI receptacle Seal all ceiling penetrations in the garage Exterior of house was not inspected
Erosion Control Inspection Residential Passed 12/7/2023 12/07/2023
Miscellaneous Correction
Resolved
12/07/2023
Full property erosion control is not in place. Erosion control must be maintained until occupancy
Miscellaneous Correction
Resolved
12/07/2023
Full erosion control is still not in place. Erosion must be installed and maintained until full CO. Install erosion control and remove dirt and gravel from the streets. This includes the lots adjacent to this property. No inspections will be completed until proper erosion control is in place. 08/29/2023 KBEARD
Miscellaneous Correction
Resolved
12/07/2023
Replace erosion control where missing or damaged along Osage Dr
Miscellaneous Correction
Informational
12/07/2023
Sod was being laid at the time of occupancy inspection. All erosion control was in place
Water Service Inspection - R Passed 8/22/2023 8/22/2023 12/08/2023
Erosion Control Inspection Residential Passed 12/12/2023 12/12/2023
Miscellaneous Correction
Informational
12/07/2023
Sod was being laid at the time of occupancy inspection. All erosion control was in place
Occupancy Inspection - Codes Residential Failed 12/8/2023 12/12/2023 12/12/2023
Miscellaneous Correction
Resolved
12/12/2023
3743 and 3745 SW Clayton TCO 3743 front porch steps are required to have a hand rail with four or more steps Seal all ceiling penetrations in garage Front door is hard to seal shut Back porch lamp is attached using interior sheet rock screws Electrical outlet under kitchen could not be test because of lack of clearance to the garbage disposal First to second riser from entrance has over the allowable 3/8 inch height difference Attic access door is not secured Smoke detectors my be faulty. Check alarm time Basement handrail is closer than the allowable 1 1/2 inches to the wall towards the bottom of the stairs Electrical panel is missing GFCI receptacle Exterior of house was not inspected 3745 front porch has 4 steps and requires a hand rail Back porch security lamp is fastened using interior sheet rock screws Electrical panel does not have attached GFCI receptacle Seal all ceiling penetrations in the garage Exterior of house was not inspected
Miscellaneous Correction
Corrective Action Required
12/12/2023
3743 - One splash pad is missing - Slope of sod in areas appear to go towards the foundation on the north side - water meter lid can not be found 3745 - area of sod by a/c condenser appears to slope towards the foundation
Occupancy Inspection - Codes Residential Ready for Temp CO 12/14/2023 12/14/2023 12/14/2023
Miscellaneous Correction
Corrective Action Required
12/12/2023
3743 - Slope of sod in areas appear to go towards the foundation on the north side 3745 - area of sod by a/c condenser appears to slope towards the foundation TCO passed for both units
Occupancy Inspection - Codes Residential Failed 12/19/2023 12/19/2023 12/19/2023
Miscellaneous Correction
Resolved
12/19/2023
3743 - Slope of sod in areas appear to go towards the foundation on the north side 3745 - area of sod by a/c condenser appears to slope towards the foundation TCO passed for both units
Miscellaneous Correction
Corrective Action Required
12/19/2023
3743 When filling in low spots in the sod, it raised the yard level within 1 1/2 inches of the exterior siding. Code allows a 6 inch height difference between the sod and the exterior siding 3745 Passed for full CofO KBEARD 12/19/23
Occupancy Inspection - Codes Residential Ready for Temp CO 12/21/2023 12/21/2023 12/21/2023
Miscellaneous Correction
Corrective Action Required
12/19/2023
3743 When filling in low spots in the sod, it raised the yard level within 1 1/2 inches of the exterior siding. Code allows a 6 inch height difference between the sod and the exterior siding 3745 Passed for full CofO KBEARD 12/19/23
Miscellaneous Correction
Corrective Action Required
12/21/2023
3743 When filling in low spots in the sod, it raised the yard level within 1 1/2 inches of the exterior siding. Code allows a 6 inch height difference between the sod and the exterior siding Passed for TCO only 3745 Passed for full CofO
Plot Plan Inspection Passed 3/6/2024 03/06/2024
Occupancy Inspection - Codes Residential Failed 3/6/2024 3/6/2024 03/06/2024
Miscellaneous Correction
Resolved
03/06/2024
3743 When filling in low spots in the sod, it raised the yard level within 1 1/2 inches of the exterior siding. Code allows a 6 inch height difference between the sod and the exterior siding 3745 Passed for full CofO KBEARD 12/19/23
Miscellaneous Correction
Resolved
03/06/2024
3743 When filling in low spots in the sod, it raised the yard level within 1 1/2 inches of the exterior siding. Code allows a 6 inch height difference between the sod and the exterior siding Passed for TCO only 3745 Passed for full CofO
Miscellaneous Correction
Corrective Action Required
03/06/2024
Pay $50 fee associated with this permit. All other required inspections have been passed
Occupancy Inspection - Codes Residential Failed 4/1/2024 04/01/2024
Miscellaneous Correction
Resolved
04/01/2024
Pay $50 fee associated with this permit. All other required inspections have been passed
Miscellaneous Correction
Corrective Action Required
04/01/2024
Pay all fees and schedule another occupancy inspection for a CofO
Occupancy Inspection - Codes Residential Full C of O 4/24/2024 04/24/2024
Miscellaneous Correction
Resolved
04/24/2024
Pay all fees and schedule another occupancy inspection for a CofO
Documents & Images
Date Uploaded File Type Document Name
07/10/2023 OS #49 -Signed
07/10/2023 49 osage roof layout
07/10/2023 P230315-01 Roof Seals
07/10/2023 OS #49 - PERMIT APP
07/10/2023 LOT 49 FINAL
07/24/2023 Approved Plans approved plans
07/24/2023 Plot Plan approved plot plan
07/24/2023 Approved Plans APPROVED TRUSS DRAWINGS
07/24/2023 Approved Plans APPROVED TRUSS LAYOUT
07/24/2023 Permit Codes Residential Plan Review
07/24/2023 Permit DS Building Permit
07/24/2023 Receipt Receipt for transaction:2023-005697
07/25/2023 Letter DS Building Permit
08/03/2023 M L Crose 3743 & 3745 SW Clayton LSMO 3rd Party Footing Inspection Report 8-2-23
08/03/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/21/2023 Letter INSPECTION SUMMARY
08/22/2023 Letter INSPECTION SUMMARY
08/22/2023 Letter INSPECTION SUMMARY
08/25/2023 Letter INSPECTION SUMMARY
08/29/2023 Letter INSPECTION SUMMARY
09/28/2023 Letter INSPECTION SUMMARY
10/03/2023 Letter INSPECTION SUMMARY
10/03/2023 Letter INSPECTION SUMMARY
10/03/2023 Letter INSPECTION SUMMARY
10/03/2023 Letter INSPECTION SUMMARY
10/03/2023 Letter INSPECTION SUMMARY
10/04/2023 Letter INSPECTION SUMMARY
10/04/2023 Letter INSPECTION SUMMARY
10/09/2023 Letter INSPECTION SUMMARY
11/01/2023 Letter INSPECTION SUMMARY
11/01/2023 Letter INSPECTION SUMMARY
11/02/2023 Letter INSPECTION SUMMARY
11/08/2023 Letter INSPECTION SUMMARY
11/08/2023 Letter INSPECTION SUMMARY
11/14/2023 Letter INSPECTION SUMMARY
11/28/2023 Letter INSPECTION SUMMARY
12/07/2023 Letter INSPECTION SUMMARY
12/07/2023 Letter INSPECTION SUMMARY
12/07/2023 Letter INSPECTION SUMMARY
12/07/2023 Letter INSPECTION SUMMARY
12/12/2023 Letter INSPECTION SUMMARY
12/12/2023 Letter INSPECTION SUMMARY
12/14/2023 Letter INSPECTION SUMMARY
12/14/2023 Letter INSPECTION SUMMARY
12/14/2023 Certificate/License Codes Temporary Certificate of Occupancy
12/14/2023 Receipt Receipt for transaction:2023-009103
12/19/2023 Letter INSPECTION SUMMARY
01/29/2024 LOT 49 ASBUILT ROUGH
03/01/2024 Certificate/License Codes Temporary Certificate of Occupancy
03/01/2024 Receipt Receipt for transaction:2024-001288
03/06/2024 Letter INSPECTION SUMMARY
03/06/2024 Letter INSPECTION SUMMARY
04/01/2024 Letter INSPECTION SUMMARY
04/23/2024 Certificate/License Codes Temporary Certificate of Occupancy
04/23/2024 Receipt Receipt for transaction:2024-002591
04/24/2024 Letter Field Certificate of Occupancy
04/24/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: