Summary
PRRES20231881
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT = ROOF TRUSSES - STOP WORK ORDER generated on 01/30/2024 12:00 AM by username 'Kyle Beard'. STOP WORK ORDER removed on 02/01/2024 12:00 AM by username 'Kyle Beard'.
04/28/2023
05/02/2023
06/28/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
Savanna Scarbo, Address:120 SE 30th st, Phone:(816) 246-6700  
SAVANNA@SUMMITHOMESKC.COM  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 05/02/2023
Right of Way Permit Fee $85.00 $85.00 Paid 05/02/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 05/02/2023
Water Tap Fee $3,730.00 $3,730.00 Paid 05/02/2023
Water Meter Fee $550.50 $550.50 Paid 05/02/2023
Valuation Fee New Single Family $1,431.26 $1,431.26 Paid 05/02/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 03/24/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 06/27/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 06/27/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/5/2023 06/05/2023
Misc
Informational
06/05/2023
Footing was signed off by a third party. Piers were not signed off in their inspection report
Sewer Service Inspection - R Passed 6/19/2023 (10:00) 6/19/2023 06/19/2023
Water Service Inspection - R Passed 6/19/2023 (1:00) 6/19/2023 06/19/2023
Underslab Plumbing Inspection - Residential Passed 6/27/2023 6/27/2023 06/27/2023
Erosion Control Inspection Residential Partial 6/27/2023 06/27/2023
Misc
Informational
06/27/2023
Erosion control is in place at the time of Under slab plumbing inspection.
Miscellaneous Inspection Passed 11/15/2023 11/15/2023
Miscellaneous Correction
Informational
11/15/2023
Builder applied for a permit extension. This miscellaneous inspection is to extend the permit. 11/15/23 KBEARD
Erosion Control Inspection Residential Failed 11/16/2023 11/16/2023
Misc
Informational
06/27/2023
Erosion control is in place at the time of Under slab plumbing inspection.
Miscellaneous Correction
Corrective Action Required
11/16/2023
Part of erosion control is missing or damaged and is not providing full erosion control. Full erosion control is required until full CofO
All Rough Inspection - Residential Failed 1/3/2024 1/3/2024 01/03/2024
Miscellaneous Correction
Corrective Action Required
01/03/2024
2129 SW Rutherford. All rough Garage anchor bolts need to be in the middle 1/3 of sole plate Fire block garage to house blocking that was notched for wiring in stud cavity Fire block top of chase in garage S/E corner Electrical receptacle in garage is not installed in the wall Ceiling joist in garage to house entry powder bathroom has been notched up to 1/2 of the joist Powder bathroom exhaust vent is not attached to the vent piping Powder bathroom top plate needs to be fire blocked Nails are missing in joist hanger at entry/stairwell/living room Nail outside wall kitchen corner 12 inches on center Fire block walls in stairwell north wall Chase in between bedroom 3 and 4 needs to be fire blocked at the ceiling with 3/4 inch wood Trusses in bedroom 4 and primary bathroom needs support hangers installed Nail double truss in primary together Primary bedroom closet is missing a truss tie down screw Tie down bracket in stairwell is not installed Stairwell stringer is not properly supported Gas line is not bonded Air supply line in basement needs to be supported Electrical panel is not bonded utilizing the Ufer
Erosion Control Inspection Residential Partial 1/3/2024 01/03/2024
Misc
Informational
11/16/2023
Erosion control is in place at the time of Under slab plumbing inspection.
Miscellaneous Correction
Resolved
01/03/2024
Part of erosion control is missing or damaged and is not providing full erosion control. Full erosion control is required until full CofO
Miscellaneous Correction
Informational
01/03/2024
Erosion control is in place at the time of all rough inspection
All Rough Inspection - Residential Passed 1/8/2024 1/8/2024 01/08/2024
Miscellaneous Correction
Resolved
01/08/2024
2129 SW Rutherford. All rough Garage anchor bolts need to be in the middle 1/3 of sole plate Fire block garage to house blocking that was notched for wiring in stud cavity Fire block top of chase in garage S/E corner Electrical receptacle in garage is not installed in the wall Ceiling joist in garage to house entry powder bathroom has been notched up to 1/2 of the joist Powder bathroom exhaust vent is not attached to the vent piping Powder bathroom top plate needs to be fire blocked Nails are missing in joist hanger at entry/stairwell/living room Nail outside wall kitchen corner 12 inches on center Fire block walls in stairwell north wall Chase in between bedroom 3 and 4 needs to be fire blocked at the ceiling with 3/4 inch wood Trusses in bedroom 4 and primary bathroom needs support hangers installed Nail double truss in primary together Primary bedroom closet is missing a truss tie down screw Tie down bracket in stairwell is not installed Stairwell stringer is not properly supported Gas line is not bonded Air supply line in basement needs to be supported Electrical panel is not bonded utilizing the Ufer
Electrical Service Inspection Passed 1/10/2024 1/9/2024 01/09/2024
Gas Service Inspection - Residential Passed 1/10/2024 1/9/2024 01/09/2024
Erosion Control Inspection Residential Partial 2/1/2024 02/01/2024
Misc
Informational
01/03/2024
Erosion control is in place at the time of Under slab plumbing inspection.
Miscellaneous Correction
Informational
01/03/2024
Erosion control is in place at the time of all rough inspection
Miscellaneous Correction
Informational
02/01/2024
Full erosion control is in place and must be maintained until CofO
Driveway Inspection Partial 2/1/2024 2/1/2024 02/01/2024
Misc
Informational
02/01/2024
2-1-24 Dustin a, Dw is formed and meets city specs, Approved to pour
Driveway Inspection Passed 2/8/2024 2/8/2024 02/05/2024
Misc
Informational
02/01/2024
2-1-24 Dustin a, Dw is formed and meets city specs, Approved to pour 2-5-24 Dustin A, DW is poured. Slopes are in compliance. Passed
Sidewalk Inspection Partial 02/28/2024
Misc
Informational
02/28/2024
2-28-24 Dustin A,sw formed to city spec. Approved to pour
Sidewalk Inspection Passed 3/6/2024 3/6/2024 03/04/2024
Misc
Informational
02/28/2024
2-28-24 Dustin A,sw formed to city spec. Approved to pour 3-4-24 Dustin A, sw is poured to city specs, slopes are in compliance . Passed
Erosion Control Inspection Residential Partial 3/12/2024 03/12/2024
Misc
Informational
02/01/2024
Erosion control is in place at the time of Under slab plumbing inspection.
Miscellaneous Correction
Informational
02/01/2024
Erosion control is in place at the time of all rough inspection
Miscellaneous Correction
Informational
02/01/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Informational
03/12/2024
Full erosion control is in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Failed 3/15/2024 3/15/2024 03/15/2024
Miscellaneous Correction
Corrective Action Required
03/15/2024
2129 SW Rutherford. Occupancy Garage ceiling penetrations must be fire blocked Light fixture off garage entry is hanging down Basement bottom stair to header does not have the allowable 6’8” headroom clearance Handrail from the main living going up stairs does not go down to the tip of the tread nosing Primary bedroom windows are under 24 inches high and require fall protection Back porch security lights are under the required 8 feet minimum height Front address light is lower than the address numbers for proper illumination Exterior of house is not ready for inspection
Occupancy Inspection - Codes Residential Failed 3/21/2024 3/21/2024 03/21/2024
Miscellaneous Correction
Resolved
03/21/2024
2129 SW Rutherford. Occupancy Garage ceiling penetrations must be fire blocked Light fixture off garage entry is hanging down Basement bottom stair to header does not have the allowable 6’8” headroom clearance Handrail from the main living going up stairs does not go down to the tip of the tread nosing Primary bedroom windows are under 24 inches high and require fall protection Back porch security lights are under the required 8 feet minimum height Front address light is lower than the address numbers for proper illumination Exterior of house is not ready for inspection
Miscellaneous Correction
Corrective Action Required
03/21/2024
2129 SW Rutherford. Occupancy (2) Basement bottom stair to header does not have the allowable 6’8” headroom clearance Exterior of house is not ready for inspection
Occupancy Inspection - Codes Residential Ready for Temp CO 3/22/2024 3/22/2024 03/22/2024
Miscellaneous Correction
Resolved
03/22/2024
2129 SW Rutherford. Occupancy (2) Basement bottom stair to header does not have the allowable 6’8” headroom clearance Exterior of house is not ready for inspection
Miscellaneous Correction
Corrective Action Required
03/22/2024
Exterior of house is not ready for inspection House passed for TCO only
Occupancy Inspection - Codes Residential Not Ready 4/25/2024 04/25/2024
Miscellaneous Correction
Resolved
04/25/2024
Exterior of house is not ready for inspection House passed for TCO only
Miscellaneous Correction
Corrective Action Required
04/25/2024
No response to a TCO extension request. As graded plot plan has never been submitted Not ready
Plot Plan Inspection Passed 5/1/2024 05/01/2024
Occupancy Inspection - Codes Residential Not Ready 5/24/2024 05/24/2024
Miscellaneous Correction
Resolved
05/24/2024
No response to a TCO extension request. As graded plot plan has never been submitted Not ready
Miscellaneous Correction
Corrective Action Required
05/24/2024
No response to a TCO extension request. Not ready
Erosion Control Inspection Residential Passed 6/25/2024 06/25/2024
Misc
Resolved
06/25/2024
Erosion control is in place at the time of Under slab plumbing inspection.
Miscellaneous Correction
Resolved
06/25/2024
Erosion control is in place at the time of all rough inspection
Miscellaneous Correction
Resolved
06/25/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Resolved
06/25/2024
Full erosion control is in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Full C of O 6/28/2024 06/28/2024
Miscellaneous Correction
Resolved
06/28/2024
No response to a TCO extension request. Not ready
Documents & Images
Date Uploaded File Type Document Name
04/28/2023 OS #69- signed
04/28/2023 69 osage roof layout
04/28/2023 OS #69 Permit App
04/28/2023 LOT 69 FINAL
04/28/2023 P230133 - Clover and Hive - Osage Lot 69 - Sealed Drawings
05/02/2023 Approved Plans APPROVED PLANS
05/02/2023 Approved Plans APPROVED PLANS
05/02/2023 Approved Plans approved plot plan
05/02/2023 Approved Plans APPROVED TRUSS LAYOUT
05/02/2023 Approved Plans APPROVED TRUSS PACKAGE
05/02/2023 Permit Codes Residential Plan Review
05/02/2023 Permit Codes Residential Plan Review
05/02/2023 Permit DS Building Permit
05/02/2023 Permit DS Building Permit
05/02/2023 Receipt Receipt for transaction:2023-002657
05/23/2023 OS #69 REVISION 5-19-23 SIGNED
05/24/2023 Approved Plans APPROVED REVISED PLANS
06/04/2023 M L Crose 2129 SW Rutherford Dr LSMO Osage Lot 69 Clayton P 2023-1881 3rd Party Footing Inspection Report 5-31-23 _docx
06/05/2023 Letter INSPECTION SUMMARY
06/05/2023 Letter INSPECTION SUMMARY
06/19/2023 Letter INSPECTION SUMMARY
06/19/2023 Letter INSPECTION SUMMARY
06/19/2023 Letter INSPECTION SUMMARY
06/19/2023 Letter INSPECTION SUMMARY
06/19/2023 Letter INSPECTION SUMMARY
06/19/2023 Letter INSPECTION SUMMARY
06/19/2023 Letter INSPECTION SUMMARY
06/19/2023 Letter INSPECTION SUMMARY
06/27/2023 Letter INSPECTION SUMMARY
06/27/2023 Letter INSPECTION SUMMARY
06/27/2023 Letter INSPECTION SUMMARY
06/27/2023 Letter INSPECTION SUMMARY
06/27/2023 Letter INSPECTION SUMMARY
06/27/2023 Letter INSPECTION SUMMARY
06/27/2023 Letter INSPECTION SUMMARY
11/14/2023 Letter Codes 140 Day Letter
11/14/2023 OS 69 Permit Extension
11/15/2023 Letter INSPECTION SUMMARY
11/15/2023 Letter INSPECTION SUMMARY
11/16/2023 Letter INSPECTION SUMMARY
11/16/2023 Letter INSPECTION SUMMARY
11/16/2023 Letter INSPECTION SUMMARY
01/03/2024 Letter INSPECTION SUMMARY
01/03/2024 Letter INSPECTION SUMMARY
01/03/2024 Letter INSPECTION SUMMARY
01/03/2024 Letter INSPECTION SUMMARY
01/03/2024 Letter Codes 140 Day Letter
01/03/2024 Letter INSPECTION SUMMARY
01/03/2024 Letter INSPECTION SUMMARY
01/03/2024 Letter INSPECTION SUMMARY
01/08/2024 Letter INSPECTION SUMMARY
01/08/2024 Letter INSPECTION SUMMARY
01/09/2024 Letter INSPECTION SUMMARY
01/09/2024 Letter INSPECTION SUMMARY
01/09/2024 Letter INSPECTION SUMMARY
01/09/2024 Letter INSPECTION SUMMARY
02/01/2024 Letter INSPECTION SUMMARY
02/01/2024 Letter INSPECTION SUMMARY
02/01/2024 Letter INSPECTION SUMMARY
02/05/2024 Letter INSPECTION SUMMARY
02/05/2024 Letter INSPECTION SUMMARY
02/28/2024 Letter INSPECTION SUMMARY
03/04/2024 Letter INSPECTION SUMMARY
03/12/2024 Letter INSPECTION SUMMARY
03/15/2024 Letter INSPECTION SUMMARY
03/15/2024 Letter INSPECTION SUMMARY
03/21/2024 Letter INSPECTION SUMMARY
03/22/2024 Letter INSPECTION SUMMARY
03/24/2024 Certificate/License Codes Temporary Certificate of Occupancy
03/24/2024 Certificate/License Codes Temporary Certificate of Occupancy
03/24/2024 Receipt Receipt for transaction:2024-001834
04/30/2024 LOT 69 ASBUILT
04/30/2024 Plot Plan approved as graded plot plan
05/01/2024 Letter INSPECTION SUMMARY
05/01/2024 Letter INSPECTION SUMMARY
05/24/2024 Letter INSPECTION SUMMARY
06/25/2024 Letter INSPECTION SUMMARY
06/25/2024 Letter INSPECTION SUMMARY
06/27/2024 Receipt Receipt for transaction:2024-005232
06/28/2024 Letter Codes Final Certificate of Occupancy
06/28/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home