PRRES20231502
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 11/13/2023 12:00 AM by username 'Robb Popp'. STOP WORK ORDER removed on 11/15/2023 12:00 AM by username 'Alex Fischer'.
04/07/2023
04/17/2023
02/21/2024
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
ASHLEY@NEWMARKHOMESKC.COM  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $2,240.59 $2,240.59 Paid 04/17/2023
Right of Way Permit Fee $85.00 $85.00 Paid 04/17/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 04/17/2023
Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 04/17/2023
Water Tap Fee $3,730.00 $3,730.00 Paid 04/17/2023
Water Meter Fee $550.50 $550.50 Paid 04/17/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 12/08/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 01/03/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 01/25/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/1/2023 (11:30) 5/1/2023 05/01/2023
Erosion Control Inspection Residential Failed 5/24/2023 05/24/2023
Misc
Corrective Action Required
05/24/2023
-REPAIR SILT FENCE
Underslab Plumbing Inspection - Residential Passed 5/24/2023 5/24/2023 05/24/2023
Sewer Service Inspection - R Passed 5/30/2023 5/30/2023 05/30/2023
Water Service Inspection - R Passed 6/2/2023 (9:45) 6/2/2023 06/02/2023
Erosion Control Inspection Residential Failed 6/21/2023 6/21/2023 06/16/2023
Misc
Corrective Action Required
05/24/2023
6/16/23 -REESTBLISH EROSION CONTROL AT PERIMETER -CLEAN GRAVEL AND DEBRIS FROM STREET
All Rough Inspection - Residential Failed 6/16/2023 6/16/2023 06/16/2023
Misc
Informational
06/16/2023
6/16/23 -PFH AT GARAGE AND CSPF AT MASTER BED EXTERIOR APPROVED
Erosion Control Inspection Residential Failed 6/21/2023 6/21/2023 06/21/2023
Misc
Corrective Action Required
06/16/2023
6/21/23 -REESTBLISH EROSION CONTROL AT PERIMETER
All Rough Inspection - Residential Failed 8/18/2023 8/18/2023 08/18/2023
Misc
Informational
06/16/2023
-Maintain silt at corner -Sister stud over notched for bolt at east garage wall -DWV midpoint straps must prevent lateral movement perpendicular to axis of pipe -Nail portal frame top plate with 2 rows 16d sinkers 3” oc per detail -Dryer duct over spanned -Seal gaps in FB for exhaust fan -Pan off top of chase walls at hvac and plumbing -1/2” plywood is not approved for fireblocking used throughout -FB ceiling line at dwv in powder room -Only 2 nm cables allowed through single penetration of top plate at kitchen entrance -Block between joists at bearing wall of kitchen entry -Nail rafters to ceiling joists per code at dining -Protect dwv at bottom plate gathering room side of second floor above beam -Fireblock ceiling line at gathering room and second floor bathroom -Provide 1.5” bearing for rafters at owner’s bath -Fireblock ceiling line at window of owners suit in corners -Install and fireblock hvac chase wall in owner’s closet -Complete framing at dryer duct in utility -Solid block and nail all horizontal sheathing seams -Strap top plate lapped less than 24” both sides at loft wall -Structural straps at over bored top plates to extend 6” each way of bore -Strap top plates at exterior corners not connected at loft/ bed 3 -Sister studs over notched for bolts at rec room -Tighten anchor bolts in basement -Vertical FB max 10’ at rec room between last run in center of room and window
Electrical Service Inspection Passed 8/18/2023 8/18/2023 08/18/2023
Gas Service Inspection - Residential Passed 8/18/2023 8/18/2023 08/18/2023
All Rough Inspection - Residential Failed 8/29/2023 8/29/2023 08/29/2023
Misc
Informational
08/18/2023
**8/29/23 NO ACCESS -Maintain silt at corner -Sister stud over notched for bolt at east garage wall -DWV midpoint straps must prevent lateral movement perpendicular to axis of pipe -Nail portal frame top plate with 2 rows 16d sinkers 3” oc per detail -Dryer duct over spanned -Seal gaps in FB for exhaust fan -Pan off top of chase walls at hvac and plumbing -1/2” plywood is not approved for fireblocking used throughout -FB ceiling line at dwv in powder room -Only 2 nm cables allowed through single penetration of top plate at kitchen entrance -Block between joists at bearing wall of kitchen entry -Nail rafters to ceiling joists per code at dining -Protect dwv at bottom plate gathering room side of second floor above beam -Fireblock ceiling line at gathering room and second floor bathroom -Provide 1.5” bearing for rafters at owner’s bath -Fireblock ceiling line at window of owners suit in corners -Install and fireblock hvac chase wall in owner’s closet -Complete framing at dryer duct in utility -Solid block and nail all horizontal sheathing seams -Strap top plate lapped less than 24” both sides at loft wall -Structural straps at over bored top plates to extend 6” each way of bore -Strap top plates at exterior corners not connected at loft/ bed 3 -Sister studs over notched for bolts at rec room -Tighten anchor bolts in basement -Vertical FB max 10’ at rec room between last run in center of room and window
All Rough Inspection - Residential Failed 8/30/2023 8/30/2023 08/30/2023
Misc
Informational
08/29/2023
-Nail portal frame top plate with 2 rows 16d sinkers 3” oc per detail -Pan off top of chase walls at hvac -Fireblock ceiling line at gathering room and second floor bathroom-SEAL GAPS -Sister studs over notched for bolts at rec room -Tighten anchor bolts in basement **OK TO INSULATE-DO NOT COVER INSPECTION ITEMS
All Rough Inspection - Residential Passed 8/31/2023 8/31/2023 08/31/2023
Misc
Resolved
08/31/2023
-Fireblock ceiling line at gathering room and second floor bathroom-SEAL GAPS -Sister studs over notched for bolts at rec room -Tighten anchor bolts in basement **OK TO INSULATE-DO NOT COVER INSPECTION ITEMS
Driveway Inspection Partial 9/21/2023 9/21/2023 09/21/2023
Misc
Informational
09/21/2023
9-21-23 DP. DW was formed, aggregate compacted. Approved to pour.
Driveway Inspection Passed 9/28/2023 9/28/2023 09/28/2023
Misc
Informational
09/21/2023
9-21-23 DP. DW was formed, aggregate compacted. Approved to pour. 9-28-23 A.A, DW is poured, Forms are pulled . Passed
Erosion Control Inspection Residential Failed 11/08/2023
Misc
Resolved
11/08/2023
6/21/23 -REESTBLISH EROSION CONTROL AT PERIMETER
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/08/2023
**11/8/23 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -PROVIDE EROSION CONTROL AT PERIMETER OF LOT **IF NOT IN COMPLIANCE IN 2 BUSINESS DAYS, A STOP WORK ORDER WILL BE ISSUED
Erosion Control Inspection Residential Failed - Stop Work 11/13/2023 11/13/2023 11/13/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/08/2023
**11/8/23 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -PROVIDE EROSION CONTROL AT PERIMETER OF LOT **IF NOT IN COMPLIANCE IN 2 BUSINESS DAYS, A STOP WORK ORDER WILL BE ISSUED
Misc
Corrective Action Required
11/13/2023
***11/13/23 STOP WORK ORDER ISSUED
Erosion Control Inspection Residential Passed 11/15/2023 11/15/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
11/15/2023
Misc
Resolved
11/15/2023
Occupancy Inspection - Codes Residential Ready for Temp CO 12/6/2023 12/6/2023 12/06/2023
Misc
Corrective Action Required
12/06/2023
-Missing sod and splash pads
Occupancy Inspection - Codes Residential Ready for Temp CO 01/03/2024
Misc
Corrective Action Required
12/06/2023
-Missing sod and splash pads
Occupancy Inspection - Codes Residential Ready for Temp CO 01/24/2024
Misc
Corrective Action Required
01/03/2024
-Missing sod and splash pads
Erosion Control Inspection Residential Failed 02/06/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/06/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -MAINTAIN EROSION CONTROL METHODS AT PERIMETER OF LOT UNTIL SOD IS IN PLACE
Erosion Control Inspection Residential Passed 2/21/2024 02/21/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/06/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -MAINTAIN EROSION CONTROL METHODS AT PERIMETER OF LOT UNTIL SOD IS IN PLACE
Plot Plan Inspection Passed 2/21/2024 02/21/2024
Occupancy Inspection - Codes Residential Full C of O 2/21/2024 2/21/2024 02/21/2024
Misc
Resolved
02/21/2024
Documents & Images
Date Uploaded File Type Document Name
04/07/2023 2023_04_06_23-306 - Lot 173 Woodside Ridge_Permit Drawings
04/07/2023 LOT 173 FINAL
04/07/2023 WR173 - Lees Summit Builidng Permit Application Signed
04/12/2023 Approved Plans APPROVED PLANS
04/12/2023 Plot Plan approved plot plan
04/14/2023 Permit Codes Residential Plan Review
04/17/2023 Permit DS Building Permit
04/17/2023 Receipt Receipt for transaction:2023-002120
05/01/2023 Letter INSPECTION SUMMARY
05/24/2023 Letter INSPECTION SUMMARY
05/24/2023 Letter INSPECTION SUMMARY
05/30/2023 Letter INSPECTION SUMMARY
06/02/2023 Letter INSPECTION SUMMARY
06/14/2023 2023_06_14_23-306 - Lot 173 Woodside Ridge_Beam splice
06/16/2023 Letter INSPECTION SUMMARY
06/16/2023 Letter INSPECTION SUMMARY
06/21/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/29/2023 Letter INSPECTION SUMMARY
08/30/2023 Letter INSPECTION SUMMARY
08/31/2023 Letter INSPECTION SUMMARY
08/31/2023 Letter INSPECTION SUMMARY
09/21/2023 Letter INSPECTION SUMMARY
09/28/2023 Letter INSPECTION SUMMARY
11/08/2023 Letter INSPECTION SUMMARY
11/13/2023 Letter Stop Work Order
11/15/2023 Letter INSPECTION SUMMARY
12/08/2023 Certificate/License Codes Temporary Certificate of Occupancy
12/08/2023 Receipt Receipt for transaction:2023-008978
01/02/2024 TCOExtension Request Form
01/03/2024 Certificate/License Codes Temporary Certificate of Occupancy
01/03/2024 Receipt Receipt for transaction:2024-000031
01/24/2024 TCOExtension Request Form - Lees Summit
01/25/2024 Certificate/License Codes Temporary Certificate of Occupancy
01/25/2024 Receipt Receipt for transaction:2024-000389
02/06/2024 Letter INSPECTION SUMMARY
02/21/2024 Letter INSPECTION SUMMARY
02/21/2024 Letter INSPECTION SUMMARY
02/21/2024 Letter Field Certificate of Occupancy
02/21/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home