Permit Application Status

PRRES20225144


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20225144
Building Permit - Residential
Certificate of Occupancy
SUMMIT VIEW FARMS DEVELOPMENT GROUP LLC
NEW SINGLE FAMILY
NEW HOUSE. WALKOUT BASEMENT. COVERED DECK. UNFINSIHED BASEMENT.
10/12/2022
10/20/2022
04/12/2023
07/10/2024
Locations
Contacts
BILL KENNEY & ASSOCIATES, Address:P O BOX 291, Phone:(816) 838-0552  
SUMMIT VIEW FARMS DEVELOPMENT GROUP LLC, Address:13450 E STATE ROUTE 150  
Bill Kenney, Address:PO Box 291, Phone:(816) 838-0552  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
INHOME SYSTEMS LLC, Address:510 MISSION RD SW, Phone:(816) 372-0483  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
BILLKENNEY9@GMAIL.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 10/20/2022
8350015-Water Meter Fee $550.50 $550.50 Paid 10/20/2022
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 10/20/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/20/2022
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 10/20/2022
9110078-Valuation Fee New Single Family $1,987.31 $1,987.31 Paid 10/20/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/2/2022 12/02/2022
Underslab Plumbing Inspection - Residential Failed 12/2/2022 12/2/2022 12/02/2022
Misc
Corrective Action Required
12/02/2022
Inspection denied no address posted
Underslab Plumbing Inspection - Residential Passed 12/12/2022 12/12/2022 12/12/2022
Misc
Resolved
12/12/2022
Sewer Service Inspection - R Passed 1/9/2023 (1:00) 1/9/2023 01/09/2023
Water Service Inspection - R Passed 1/10/2023 (10:45) 1/10/2023 01/10/2023
Piers/Caissons Inspection - Residential Failed 4/14/2023 04/14/2023
Misc
Corrective Action Required
04/14/2023
-Piers to be of correct size and depth.
All Rough Inspection - Residential Failed 5/3/2023 5/3/2023 05/03/2023
Misc
Corrective Action Required
05/03/2023
- nail to code studs exterior corner bedroom 5 - Fire block top plate of chase behind shower plumbing and kitchen - Add electrical outlet at windows in great room currently 15’ apart - Unable to inspect deck and porch roof framing because they are covered - Address rafters landing on 4 blocks at entry and stairs - Address rafters landing on 4 blocks in master closet - Provide headroom at attic entrance - Finish framing exterior corner master toilet room - Solid block cantilever in basement to garage - Minimum of 3 studs at exterior corners of cripple wall basement near electrical panel - Provide anchor bolts at plate breaks basement - Provide protection plate for DWV on basements back wall - Address over notched stud basement near door - Provide missing joist at deck and plan calls for LVL -
Erosion Control Inspection Residential Partial 5/3/2023 05/03/2023
Misc
Informational
05/03/2023
Erosion control pass at time of inspection
Gas Service Inspection - Residential Passed 5/3/2023 5/3/2023 05/03/2023
Electrical Service Inspection Passed 5/3/2023 5/3/2023 05/03/2023
All Rough Inspection - Residential Failed 5/10/2023 5/10/2023 05/10/2023
Misc
Corrective Action Required
05/03/2023
( Waiting on engineers letter on correction made ) - Address rafters landing on 4 blocks at entry and stairs - Address rafters landing on 4 blocks in master closet OK to insulate
All Rough Inspection - Residential Passed 6/5/2023 06/05/2023
Misc
Resolved
06/05/2023
( Waiting on engineers letter on correction made ) - Address rafters landing on 4 blocks at entry and stairs - Address rafters landing on 4 blocks in master closet OK to insulate
Driveway Inspection Passed 7/7/2023 07/10/2023
Misc
Informational
07/07/2023
7-7-23 BR Driveway is framed and aggregate has been place and ready for concrete. 7-10-23 BR Driveway is constructed to LS specification
Sidewalk Inspection Partial 10/17/2023 10/17/2023 10/17/2023
Misc
Informational
10/17/2023
10-17-23 Dustin A, SW is formed in front of house and down to storm box on kline. Aggregate is compacted Approved to pour. Will come by tomorrow morning ( 10-18-23 ) to inspect from storm box to property line .
Sidewalk Inspection Partial 10/18/2023 (8:30) 10/18/2023 10/18/2023
Misc
Informational
10/17/2023
10-17-23 Dustin A, SW is formed in front of house and down to storm box on kline. Aggregate is compacted Approved to pour. Will come by tomorrow morning ( 10-18-23 ) to inspect from storm box to property line . 10-18-23 Dustin A, Inspected rest of SW on Kline . It is formed and aggregate is compacted. Slopes are in compliance. Instructed contractor (MLC) that forms will need to be pulled away from manhole to keep from having a trip hazard. Approved to pour.
Sidewalk Inspection Passed 10/24/2023 10/24/2023 10/23/2023
Misc
Informational
10/18/2023
10-17-23 Dustin A, SW is formed in front of house and down to storm box on kline. Aggregate is compacted Approved to pour. Will come by tomorrow morning ( 10-18-23 ) to inspect from storm box to property line . 10-18-23 Dustin A, Inspected rest of SW on Kline . It is formed and aggregate is compacted. Slopes are in compliance. Instructed contractor (MLC) that forms will need to be pulled away from manhole to keep from having a trip hazard. Approved to pour. 10-23-23 Dustin A, SW poured. Forms are pulled and slopes are in compliance. Passed
Plot Plan Inspection Passed 11/20/2023 11/20/2023 11/20/2023
Erosion Control Inspection Residential Failed 02/07/2024
Misc
Resolved
02/07/2024
Erosion control pass at time of inspection
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/07/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Install erosion control at side of lot where missing
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/07/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Piers/Caissons Inspection - Residential Passed 03/12/2024
Misc
Informational
03/12/2024
3rd party inspection report uploaded.
Occupancy Inspection - Codes Residential Failed 3/12/2024 3/12/2024 03/12/2024
Misc
Corrective Action Required
03/12/2024
-guard rail required at front stoop -uncover covered manhole N side of lot -handrail for steps in garage -(2) 1/2” through bolts at deck post to beam connection
Erosion Control Inspection Residential Passed 07/10/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
07/10/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Install erosion control at side of lot where missing
DCM2 ESC DEFICIENT INSTALLATION
Resolved
07/10/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Full C of O 7/10/2024 7/10/2024 07/10/2024
Misc
Resolved
07/10/2024
-guard rail required at front stoop -uncover covered manhole N side of lot -handrail for steps in garage -(2) 1/2” through bolts at deck post to beam connection
Documents & Images
Date Uploaded File Type Document Name
10/12/2022 111 Ex_000285
10/12/2022 111 Ap_000286
10/14/2022 Permit Codes Residential Plan Review
10/17/2022 Plot Plan APPROVED PLOT PLAN
10/20/2022 Approved Plans APPROVED PLANS
10/20/2022 Permit Codes Residential Plan Review
10/20/2022 Permit DS Building Permit
10/20/2022 Receipt Receipt for transaction:2022-008419
10/21/2022 M L Crose 3202 SW Enoch St LSMO Bill Kenney Permit 2022-5144 3rd Party Footing Inspection Report 10-21-22
12/02/2022 Letter INSPECTION SUMMARY
12/02/2022 Letter INSPECTION SUMMARY
12/12/2022 Letter INSPECTION SUMMARY
01/09/2023 Letter INSPECTION SUMMARY
01/10/2023 Letter INSPECTION SUMMARY
01/10/2023 Letter INSPECTION SUMMARY
04/14/2023 Letter INSPECTION SUMMARY
04/17/2023 Bill Kenney 3202 SW Enoch LSMO Deck Support Post Pier Inspection Report 4-14-23
04/17/2023 Pier Inspection 3202 SW Enoch LSMO Deck Support Post Pier Inspection Report 4-14-23
05/03/2023 Letter INSPECTION SUMMARY
05/03/2023 Letter INSPECTION SUMMARY
05/03/2023 Letter INSPECTION SUMMARY
05/03/2023 Letter INSPECTION SUMMARY
05/10/2023 Letter INSPECTION SUMMARY
06/02/2023 Bill Kenney 3202 SW Enoch LSMO Framing Inspection Report 5-22-23
06/03/2023 pic 1
06/03/2023 pic 2
06/03/2023 pic 3
06/05/2023 Letter INSPECTION SUMMARY
07/07/2023 Letter INSPECTION SUMMARY
07/10/2023 Letter INSPECTION SUMMARY
10/17/2023 Letter INSPECTION SUMMARY
10/17/2023 Letter INSPECTION SUMMARY
10/18/2023 Letter INSPECTION SUMMARY
10/23/2023 Letter INSPECTION SUMMARY
10/23/2023 Letter INSPECTION SUMMARY
11/20/2023 Letter INSPECTION SUMMARY
02/07/2024 Letter INSPECTION SUMMARY
03/12/2024 Letter INSPECTION SUMMARY
03/12/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter Field Certificate of Occupancy
07/10/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home