Permit Application Status

PRRES20223032


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20223032
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST RESIDENTIAL LLC
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. COVERED DECK. SUSPENDED STOOP.
07/01/2022
07/26/2022
01/15/2023
09/28/2023
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
HUNT MIDWEST RESIDENTIAL LLC, Address:8300 NE UNDERGROUND DR STE 100  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
5 STAR HEATING & COOLING, Address:211 NW 12TH, Phone:(816) 517-3341  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
WALKERCUSTOMHOMESKC@GMAIL.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 07/26/2022
8350015-Water Meter Fee $550.50 $550.50 Paid 07/26/2022
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 07/26/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 07/26/2022
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 07/26/2022
9110078-Valuation Fee New Single Family $1,563.69 $1,563.69 Paid 07/26/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/12/2022 08/12/2022
Misc
Informational
08/12/2022
third party
Underslab Plumbing Inspection - Residential Failed 8/12/2022 8/12/2022 08/12/2022
Misc
Corrective Action Required
08/12/2022
inspection denied no address posted
Water Service Inspection - R Partial 8/15/2022 08/15/2022
Sewer Service Inspection - R Passed 8/15/2022 (10:45) 8/15/2022 08/15/2022
Underslab Plumbing Inspection - Residential Passed 8/16/2022 8/16/2022 08/16/2022
Misc
Resolved
08/16/2022
inspection denied no address posted
Water Service Inspection - R Passed 8/16/2022 08/16/2022
Gas Service Inspection - Residential Passed 2/6/2023 2/6/2023 02/06/2023
Electrical Service Inspection Passed 2/6/2023 2/6/2023 02/06/2023
All Rough Inspection - Residential Failed 2/6/2023 2/6/2023 02/06/2023
Misc
Corrective Action Required
02/06/2023
-all anchor bolts to be in the middle third of sill plate -provide hangers at attic access in garage -seal dead space at bed 2 entry -fire block furr down ends in basement -address holes drilled through triple floor joist in unfinished area closer than 2” to top of joist -support 2” dwv in unfinished areas -steel column at bottom of stairs both to be 3 1/2” -address floor joist drilled through at top closer than 2” in bed 4 -address holes drilled closer than 2” to bottom of floor joist above bed 4 closet -block joist above beams
All Rough Inspection - Residential Failed 2/21/2023 2/21/2023 02/21/2023
Misc
Corrective Action Required
02/06/2023
-fire block furr down ends in basement(see basement bath) -support 2” dwv in unfinished areas(see near furnace and basement bath) OKAY TO INSULATE
All Rough Inspection - Residential Passed 2/22/2023 2/22/2023 02/22/2023
Misc
Resolved
02/22/2023
-fire block furr down ends in basement(see basement bath) -support 2” dwv in unfinished areas(see near furnace and basement bath) OKAY TO INSULATE
Driveway Inspection Partial 3/23/2023 3/23/2023 03/23/2023
Misc
Informational
03/23/2023
3-23-23 RH Driveway is formed up and aggregate is placed and compacted. Approved to pour.
Driveway Inspection Passed 3/30/2023 3/30/2023 03/30/2023
Misc
Informational
03/23/2023
3-23-23 RH Driveway is formed up and aggregate is placed and compacted. Approved to pour. 3-30-23 RH. Driveway meets LS specification.
Erosion Control Inspection Residential Failed 08/11/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/11/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Passed 8/16/2023 8/16/2023 08/16/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
08/16/2023
Occupancy Inspection - Codes Residential Failed 9/26/2023 9/26/2023 09/26/2023
Misc
Corrective Action Required
09/26/2023
-address pending pier inspection -address suspended slab not inspected -identify sewer tracer wire cap -water meter to be 14”-18” from top of meter to top of well lid ring -garage entry door to be self closing and latching -smoke detector in master dead battery
Piers/Caissons Inspection - Residential Passed 09/28/2023
Plot Plan Inspection Passed 09/28/2023
Occupancy Inspection - Codes Residential Full C of O 9/28/2023 9/28/2023 09/28/2023
Misc
Resolved
09/28/2023
-address pending pier inspection -address suspended slab not inspected -identify sewer tracer wire cap -water meter to be 14”-18” from top of meter to top of well lid ring -garage entry door to be self closing and latching -smoke detector in master dead battery
Documents & Images
Date Uploaded File Type Document Name
07/19/2022 Permit Codes Residential Plan Review
07/21/2022 Application Form APPLICATION
07/21/2022 Plot Plan APPROVED PLOT PLAN
07/21/2022 Approved Plans APPROVED PLANS
07/21/2022 Permit Codes Residential Plan Review
07/26/2022 Permit DS Building Permit
07/26/2022 Receipt Receipt for transaction:2022-006113
08/03/2022 2111 SW Red Barn Ln LSMO Retreat @ Hook Farm Lot 80 Footing Inspection Report 8-1-22
08/12/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter INSPECTION SUMMARY
08/15/2022 Letter INSPECTION SUMMARY
08/15/2022 Letter INSPECTION SUMMARY
08/16/2022 Letter INSPECTION SUMMARY
08/16/2022 Letter INSPECTION SUMMARY
12/07/2022 2111 SW Red Barn Rd ROW
02/06/2023 Letter INSPECTION SUMMARY
02/06/2023 Letter INSPECTION SUMMARY
02/06/2023 Letter INSPECTION SUMMARY
02/21/2023 2111 SW Red Barn Lane - Structural Letter
02/21/2023 Letter INSPECTION SUMMARY
02/22/2023 Letter INSPECTION SUMMARY
03/23/2023 Letter INSPECTION SUMMARY
03/30/2023 Letter INSPECTION SUMMARY
08/11/2023 Letter INSPECTION SUMMARY
08/16/2023 Letter INSPECTION SUMMARY
09/26/2023 Letter INSPECTION SUMMARY
09/26/2023 2111 SW Red Barn
09/28/2023 Letter INSPECTION SUMMARY
09/28/2023 Letter INSPECTION SUMMARY
09/28/2023 Letter Field Certificate of Occupancy
09/28/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home