Permit Application Status

PRRES20223002


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20223002
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST RESIDENTIAL LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
06/30/2022
06/30/2022
03/21/2023
Locations
Contacts
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
HUNT MIDWEST RESIDENTIAL LLC, Address:8300 NE UNDERGROUND DR STE 100  
Joseph Matthew Schartz, Address:PO Box 942, Phone:(816) 524-3855  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
TEAGUE ELECTRIC CONSTRUCTION INC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
Zack Bryant, Address:200 NW Commerce CT  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,171.30 $1,171.30 Paid 06/30/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 06/30/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 06/30/2022
8331507-Sewer Connection Fee $450.00 $450.00 Paid 06/30/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 06/30/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 06/30/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/1/2022 08/01/2022
Sewer Service Inspection - R Failed 8/1/2022 (10:45) 8/1/2022 08/01/2022
Misc
Corrective Action Required
08/01/2022
address undermind footing meet on site with level to show proper slope and fall
Sewer Service Inspection - R Passed 8/1/2022 (1:00) 8/1/2022 08/01/2022
Misc
Corrective Action Required
08/01/2022
address undermind footing meet on site with level to show proper slope and fall
Underslab Plumbing Inspection - Residential Failed 8/10/2022 8/10/2022 08/10/2022
Misc
Corrective Action Required
08/10/2022
inspection denied no address posted
Underslab Plumbing Inspection - Residential Passed 8/11/2022 8/11/2022 08/11/2022
Misc
Resolved
08/11/2022
inspection denied no address posted
Piers/Caissons Inspection - Residential Partial 8/12/2022 (1:00) 8/12/2022 08/12/2022
Misc
Corrective Action Required
08/12/2022
missing middle S most pier all other piers okay to pour
Gas Service Inspection - Residential Passed 11/15/2022 11/15/2022 11/15/2022
Electrical Service Inspection Passed 11/15/2022 11/15/2022 11/15/2022
Erosion Control Inspection Residential Failed 11/15/2022 11/15/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
11/15/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/15/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. see rear of lot
All Rough Inspection - Residential Failed 11/15/2022 11/15/2022 11/15/2022
Misc
Corrective Action Required
11/15/2022
No further inspections until erosion control is restored -install door in garage -missing nails in stud shoe for SE cable -anchor bolts to be in the middle 1/3 of sill plate -protect NM within 6’ of attic access -seal penetration into furr down kitchen/entry -nail all exterior wall corners to code/plans -uncover covered patios for inspection -fireblock right of great room windows -fire block right and left of fireplace -secure gas line at fireplace within 12” of disconnect -midway strap dwv 2” or less in diameter in master -missing stud in master/master bath -furr around b vent in bed 2 be sure to fire block -seal penetration in RA in bed 2 stud space -over notched stud basement gaming area -seal all penetrations and gaps in vertical to horizontal fireblocking -all anchor bolts to be tight -seal gaps from stud space into furr down in bed 3 -over notched stud bed 3 -seal penetrations in R/a bed 3 -seal stud space into furr down bed 3 WI closet -vertical to horizontal fireblocking missing. Basement W wall -seal vertical penetrations in fire blocking above bath sink in basement W wall -seal penetrations in bed 4 R/a stud space -midway strap dwv at wet bar -double every joist above family room when noted in plans
All Rough Inspection - Residential Failed 11/22/2022 11/22/2022 11/22/2022
Misc
Corrective Action Required
11/15/2022
-furr around b vent in bed 2 be sure to fire block -seal gaps from stud space into furr down in bed 3 -address holes drilled closer than 2” from each other above bed 3 -seal stud space into furr down bed 3 WI closet -vertical to horizontal fireblocking missing. Basement W wall (not completed) -missing hangers on double around entry Okay to insulate
All Rough Inspection - Residential Passed 11/28/2022 11/28/2022 11/28/2022
Misc
Resolved
11/28/2022
-furr around b vent in bed 2 be sure to fire block -seal gaps from stud space into furr down in bed 3 -address holes drilled closer than 2” from each other above bed 3 -seal stud space into furr down bed 3 WI closet -vertical to horizontal fireblocking missing. Basement W wall (not completed) -missing hangers on double around entry Okay to insulate
Piers/Caissons Inspection - Residential Passed 12/14/2022 (9:15) 12/14/2022 12/14/2022
Misc
Resolved
12/14/2022
missing middle S most pier all other piers okay to pour
Water Service Inspection - R Passed 1/4/2023 (9:30) 1/4/2023 01/04/2023
Driveway Inspection Partial 2/6/2023 2/6/2023 02/06/2023
Misc
Informational
02/06/2023
2-6-23 RH. Driveway is formed up and aggreagate is placed and compacted. Approved to pour.
Sidewalk Inspection Partial 2/6/2023 2/6/2023 02/06/2023
Misc
Informational
02/06/2023
2-6-23 RH. Sidewalk is formed up and aggreagte is placed and compacted. Approved to pour.
Driveway Inspection Passed 2/13/2023 2/13/2023 02/13/2023
Misc
Informational
02/06/2023
2-6-23 RH. Driveway is formed up and aggreagate is placed and compacted. Approved to pour. 2-13-23 RH. Driveway meets LS and ADA specification.
Sidewalk Inspection Passed 2/13/2023 2/13/2023 02/13/2023
Misc
Informational
02/06/2023
2-6-23 RH. Sidewalk is formed up and aggreagte is placed and compacted. Approved to pour. 2-13-23 RH. Sidewalk meets LS and ADA specification.
Erosion Control Inspection Residential Failed 2/22/2023 02/22/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Resolved
02/22/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. see rear of lot
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/22/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Plot Plan Inspection Passed 03/15/2023
Occupancy Inspection - Codes Residential Failed 3/17/2023 3/17/2023 03/17/2023
Misc
Corrective Action Required
03/15/2023
-address deck post to beam connections (not addressed to code -missing nails in deck joist hangers
Occupancy Inspection - Codes Residential Failed 3/15/2023 3/15/2023 03/20/2023
Misc
Corrective Action Required
03/15/2023
-sod -splash blocks and sump pump discharge to extend 36” from foundation -address deck post to beam connections
Occupancy Inspection - Codes Residential Failed 3/20/2023 3/20/2023 03/20/2023
Misc
Corrective Action Required
03/17/2023
-address deck post to beam connections (not addressed to code -missing nails in deck joist hangers - Items are not properly addressed at the time of inspection 03/20/2023. Kyle
Erosion Control Inspection Residential Passed 03/21/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
03/21/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
03/21/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Full C of O 03/21/2023
Misc
Resolved
03/21/2023
-address deck post to beam connections (not addressed to code -missing nails in deck joist hangers - Items are not properly addressed at the time of inspection 03/20/2023. Kyle
Documents & Images
Date Uploaded File Type Document Name
06/30/2022 HF030 - Permit Application
06/30/2022 HF030 - Excise Tax Application
06/30/2022 HF030 - Air Combustion Calculation
06/30/2022 Approved Plans Approved Drawings
06/30/2022 Plot Plan Approved Plot Plan
06/30/2022 Permit Codes Residential Plan Review
06/30/2022 Permit DS Building Permit
06/30/2022 Receipt Receipt for transaction:2022-005408
07/12/2022 M L Crose 2043 SW Hook Farm Dr LSMO Hook Farms Lot 30 SAB Permit 2022-3002 Foundation footing Inspection Report 7-11-22
08/01/2022 Letter INSPECTION SUMMARY
08/01/2022 Letter INSPECTION SUMMARY
08/01/2022 Letter INSPECTION SUMMARY
08/10/2022 Letter INSPECTION SUMMARY
08/11/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter INSPECTION SUMMARY
11/15/2022 Letter INSPECTION SUMMARY
11/15/2022 Letter INSPECTION SUMMARY
11/15/2022 Letter INSPECTION SUMMARY
11/15/2022 Letter INSPECTION SUMMARY
11/22/2022 Letter INSPECTION SUMMARY
11/28/2022 Letter INSPECTION SUMMARY
12/14/2022 Letter INSPECTION SUMMARY
12/14/2022 Letter INSPECTION SUMMARY
01/04/2023 Letter INSPECTION SUMMARY
02/06/2023 Letter INSPECTION SUMMARY
02/06/2023 Letter INSPECTION SUMMARY
02/13/2023 Letter INSPECTION SUMMARY
02/13/2023 Letter INSPECTION SUMMARY
02/22/2023 Letter INSPECTION SUMMARY
03/15/2023 Letter INSPECTION SUMMARY
03/17/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/21/2023 Letter Codes Final Certificate of Occupancy
03/21/2023 Letter Field Certificate of Occupancy
03/21/2023 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home