Permit Application Status

PRRES20222409


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20222409
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE. ROOF TRUSSES. CLAY TILE ROOF. UNFINISHED BASEMENT. COVERED PATIO.
06/01/2022
06/06/2022
11/29/2022
04/05/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
EMILYM@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $390.00 $390.00 Paid 06/06/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 06/06/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 06/06/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 06/06/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 06/06/2022
9110078-Valuation Fee New Single Family $946.37 $946.37 Paid 06/06/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 01/04/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 01/04/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/28/2022 (10:45) 6/28/2022 06/28/2022
Misc
Informational
06/28/2022
UFER on garage wall 5’ from exterior.
Sewer Service Inspection - R Passed 7/14/2022 (1:00) 7/14/2022 07/14/2022
Water Service Inspection - R Passed 7/15/2022 (1:00) 7/15/2022 07/15/2022
Underslab Plumbing Inspection - Residential Failed 7/20/2022 7/20/2022 07/20/2022
Misc
Corrective Action Required
07/20/2022
inspection denied no erosion control no address
Erosion Control Inspection Residential Failed 7/20/2022 07/20/2022
DCM5 ESC INSP DENIED
Corrective Action Required
07/20/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/20/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Underslab Plumbing Inspection - Residential Passed 7/22/2022 7/22/2022 07/22/2022
Misc
Resolved
07/22/2022
inspection denied no erosion control
Electrical Service Inspection Passed 10/4/2022 10/04/2022
All Rough Inspection - Residential Failed 10/4/2022 10/4/2022 10/04/2022
Misc
Corrective Action Required
10/04/2022
-strap top plate lapped less than 24” at owners entry and hvac chase -cspf at rear slider per plans -install lib in bath 2 to plans and code -sold block sheathing breaks in bed 2 -missing joist hangers above bed 2 -address truss bearing and missing hold downs at garage E wall/foyer wall -properly support gas line near column A in basement -address over notched floor joisted for 3” dwv in basement near column A -address over notched floor joist for dwv below bath 2 -provide pressure at gas gauge
All Rough Inspection - Residential Failed 10/10/2022 10/10/2022 10/10/2022
Misc
Corrective Action Required
10/04/2022
-install lib in bath 2 to plans and code-NOT DONE -missing joist hangers above bed 2-ADDRESS TRUSS DAMAGED AT HANGER -address over notched floor joisted for 3” dwv in basement near column A-JOIST NOTCHED FOR MASTER SHOWER -address over notched floor joist for dwv below bath 2-FIREBLOCK TUB TRAP
Gas Service Inspection - Residential Passed 10/10/2022 10/10/2022
All Rough Inspection - Residential Not Ready 10/13/2022 10/13/2022 10/13/2022
Misc
Corrective Action Required
10/10/2022
-install lib in bath 2 to plans and code-NOT DONE - BED 2-ADDRESS TRUSS DAMAGED AT HANGER REPAIR TO ENGINEER SPECIFICATIONS
All Rough Inspection - Residential Not Ready 10/14/2022 10/14/2022 10/14/2022
Misc
Corrective Action Required
10/13/2022
- BED 2-ADDRESS TRUSS DAMAGED AT HANGER REPAIR TO ENGINEER SPECIFICATIONS ATTACH < 2 LAYERS > 3/4" PLYWOOD OR OSB GUSSET (23/32" RATED SHEATHING 48/24 EXP 1) TO ONE FACE OF TRUSS WITH (0.131" X 3.0") NAILS PER THE FOLLOWING NAIL SCHEDULE: 2 X 3'S - 2 ROWS, 2 X 4'S - 3 ROWS, 2 X 6'S AND LARGER - 4 ROWS: SPACED @ 2" O.C. USE 2" MEMBER END DISTANCE. GLUE PLYWOOD LAYERS TOGETHER PRIOR TO ATTACHING TO TRUSS. 3/4" is actually 23/32 thick 1/2" is actually 15/32 thick this was used for repair not what engineer recommended in repair letter
Driveway Inspection Partial 10/17/2022 10/17/2022 10/17/2022
Misc
Informational
10/17/2022
Driveway was framed up with aggregate in and compacted. 10/17/22 ES
All Rough Inspection - Residential Passed 10/18/2022 10/18/2022 10/18/2022
Misc
Resolved
10/18/2022
Driveway Inspection Partial 10/21/2022 10/21/2022 10/21/2022
Misc
Informational
10/17/2022
Driveway was framed up with aggregate in and compacted. 10/17/22 ES Driveway meets LS spec, no sidewalk. 10/21/22 ES
Driveway Inspection Passed 10/21/2022
Misc
Informational
10/21/2022
Driveway was framed up with aggregate in and compacted. 10/17/22 ES Driveway meets LS spec, no sidewalk. 10/21/22 ES
Erosion Control Inspection Residential Passed 12/30/2022 12/30/2022
DCM5 ESC INSP DENIED
Resolved
12/30/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
DCM3 ESC REQUIRED 2 DAY
Resolved
12/30/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Failed 12/30/2022 12/30/2022 12/30/2022
Misc
Corrective Action Required
12/30/2022
- final grading and sod - Provide splash blocks - Address to be contrasting in color - Pay all fees - Back fill landing and sidewalk at front door - Land trace wire at grade - Uncover smoke detectors - Provide hardware and lock for sliding door - Provide secondary lock on sliding door - Provide lid for attic access - Cap future plumbing stubs in basement - Support gas line basement - Sump discharge 36” from foundation - Seal exterior penetrations at coax entry - Lower water meter pit to grade - Lower water meter to 14-18” below grade
Occupancy Inspection - Codes Residential Failed 4/4/2023 4/4/2023 04/04/2023
Misc
Partial Correction
04/04/2023
- final grading and sod - Provide splash blocks - Address to be contrasting in color - Pay all fees - Back fill landing and sidewalk at front door - Land trace wire at grade - Uncover smoke detectors - Provide hardware and lock for sliding door - Provide secondary lock on sliding door - Provide lid for attic access - Cap future plumbing stubs in basement - Support gas line basement - Sump discharge 36” from foundation - Seal exterior penetrations at coax entry - Lower water meter pit to grade - Lower water meter to 14-18” below grade
Misc
Corrective Action Required
04/04/2023
- Seal exterior penetrations at coax entry and above service entrance -Provide proper drainage at egress window
Occupancy Inspection - Codes Residential Full C of O 4/5/2023 4/5/2023 04/05/2023
Misc
Resolved
04/05/2023
Misc
Resolved
04/05/2023
- Seal exterior penetrations at coax entry and above service entrance -Provide proper drainage at egress window
Documents & Images
Date Uploaded File Type Document Name
06/01/2022 W1 #34 - PERMIT APP
06/01/2022 Approved Plans APPROVED PLANS
06/02/2022 Permit Codes Residential Plan Review
06/02/2022 Approved Plans APPROVED TRUSS PACKAGE
06/02/2022 Approved Plans APPROVED TRUSS LAYOUT
06/03/2022 Plot Plan APPROVED PLOT PLAN
06/03/2022 Permit Codes Residential Plan Review
06/06/2022 Permit DS Building Permit
06/06/2022 Receipt Receipt for transaction:2022-004295
06/28/2022 Letter INSPECTION SUMMARY
06/28/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/15/2022 Letter INSPECTION SUMMARY
07/20/2022 Letter INSPECTION SUMMARY
07/20/2022 Letter INSPECTION SUMMARY
07/22/2022 Letter INSPECTION SUMMARY
10/04/2022 Letter INSPECTION SUMMARY
10/04/2022 Letter INSPECTION SUMMARY
10/10/2022 34 woodside ridge letter
10/10/2022 34 woodside ridge letter #2
10/10/2022 Letter INSPECTION SUMMARY
10/10/2022 Letter INSPECTION SUMMARY
10/12/2022 Approved Plans APPROVED TRUSS LETTER
10/13/2022 Letter INSPECTION SUMMARY
10/14/2022 Letter INSPECTION SUMMARY
10/14/2022 Letter INSPECTION SUMMARY
10/17/2022 Letter INSPECTION SUMMARY
10/18/2022 Letter INSPECTION SUMMARY
10/21/2022 Letter INSPECTION SUMMARY
10/21/2022 Letter INSPECTION SUMMARY
12/30/2022 Letter INSPECTION SUMMARY
12/30/2022 Letter INSPECTION SUMMARY
01/04/2023 Receipt Receipt for transaction:2023-000047
04/04/2023 Letter INSPECTION SUMMARY
04/05/2023 Letter Field Certificate of Occupancy
04/05/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home