Permit Application Status

PRRES20221447


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20221447
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEENT - COVERED PATIO
04/13/2022
04/18/2022
10/11/2022
04/13/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
THAD@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,364.68 $1,364.68 Paid 04/18/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 04/18/2022
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 04/18/2022
8331507-Sewer Connection Fee $480.00 $480.00 Paid 04/18/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 04/18/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 04/18/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/5/2022 (2:00) 5/5/2022 05/05/2022
Underslab Plumbing Inspection - Residential Passed 5/31/2022 5/31/2022 05/31/2022
Sewer Service Inspection - R Passed 6/14/2022 (9:15) 6/14/2022 06/14/2022
Water Service Inspection - R Passed 6/15/2022 (9:45) 6/15/2022 06/15/2022
Erosion Control Inspection Residential Failed 6/15/2022 6/15/2022 06/15/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/15/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Passed 8/30/2022 8/30/2022 08/30/2022
Gas Service Inspection - Residential Passed 8/30/2022 8/30/2022 08/30/2022
All Rough Inspection - Residential Failed 8/30/2022 8/30/2022 08/30/2022
Misc
Corrective Action Required
08/30/2022
-no approved truss plans on site, unable to verify trusses, have on site at reinspect -fireblock plumbing chases at garage -seal penetrations at fireblock furred down soffit end garage wall -top plate corner lap connection as required by code - see garage wall (different wall heights) -fireblock all tub traps -snow block mud room -provide protection plate bottom plate pex for fridge kitchen -provide stud shoe for king and trimmer studs bored for DWV kitchen exterior wall -seal top and bottom plate penetrations S kitchen stair wall -code compliant attic access size per plans garage -min 24” lap between dbl top plate breaks, see kitchen load bearing wall -provide dbl joist hanger at joist to lvl at foyer -LIB bracing bed#5 per plans -provide (4) 2x4 stud pack bed #5 for 2nd floor girder truss bearing per plans -provide (4) 2x4 stud pack all girder truss bearing locations per plans - see bath#2 -provide bocca protection plate top plate DWV bath #2 and bed#2 wall -protect NM within 6’ of attic entrance -install basement egress window -provide (3) 2x4 stud pack at pier location “A” basement stair wall per plans
Erosion Control Inspection Residential Partial 08/30/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/30/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Failed 9/14/2022 9/14/2022 09/14/2022
Misc
Corrective Action Required
08/30/2022
-fireblock plumbing chases at garage -seal penetrations at fireblock furred down soffit end garage wall -top plate corner lap connection as required by code - see garage wall (different wall heights) -LIB bracing bed#5 per plans
Erosion Control Inspection Residential Partial 09/14/2022
All Rough Inspection - Residential Passed 9/23/2022 9/23/2022 09/23/2022
Misc
Resolved
09/23/2022
Driveway Inspection Passed 11/1/2022 11/1/2022 11/01/2022
Misc
Informational
11/01/2022
On Tuesday, 11-01-2022 I performed and passed a driveway inspection for placement of concrete.
Sidewalk Inspection Passed 11/1/2022 11/1/2022 11/01/2022
Misc
Informational
11/01/2022
On Tuesday, 11-01-2022 I performed and passed a sidewalk inspection for concrete placement.
Occupancy Inspection - Codes Residential Failed 1/20/2023 1/20/2023 01/20/2023
Misc
Corrective Action Required
01/20/2023
- final grading and sod - Provide splash pads - Provide guard rail side of front porch - Sump discharge to be 36” away from foundation - Steps to basement from landing to basement have a rise over 7 3/4” - No inspection for patio roof piers
Piers/Caissons Inspection - Residential Passed 04/11/2023
Occupancy Inspection - Codes Residential Failed 4/11/2023 4/11/2023 04/11/2023
Misc
Corrective Action Required
01/20/2023
-step up from basement landing to landing has a riser over 7 3/4
Plot Plan Inspection Passed 4/13/2023 04/13/2023
Erosion Control Inspection Residential Passed 4/13/2023 04/13/2023
Occupancy Inspection - Codes Residential Full C of O 4/13/2023 4/13/2023 04/13/2023
Misc
Corrective Action Required
04/11/2023
-step up from basement landing to landing has a riser over 7 3/4
Documents & Images
Date Uploaded File Type Document Name
04/13/2022 CB #26 - PERMIT APPLICATION
04/13/2022 CB #26 - Riverside - Modern Farmhouse - Sheets- signed
04/13/2022 Approved Plans Approved Drawings
04/13/2022 Approved Plans Approved Truss Layout
04/13/2022 Approved Plans Approved Truss Package
04/14/2022 Permit Codes Residential Plan Review
04/18/2022 Plot Plan Approved Plot Plan
04/18/2022 Permit Codes Residential Plan Review
04/18/2022 Permit DS Building Permit
04/18/2022 Receipt Receipt for transaction:2022-002137
05/05/2022 Letter INSPECTION SUMMARY
05/31/2022 Letter INSPECTION SUMMARY
06/14/2022 Letter INSPECTION SUMMARY
06/15/2022 Letter INSPECTION SUMMARY
06/15/2022 Letter INSPECTION SUMMARY
08/29/2022 Strong-Drive® SDWC TRUSS PT3
08/30/2022 Letter INSPECTION SUMMARY
08/30/2022 Letter INSPECTION SUMMARY
08/30/2022 Letter INSPECTION SUMMARY
08/30/2022 Letter INSPECTION SUMMARY
09/14/2022 Letter INSPECTION SUMMARY
09/14/2022 Letter INSPECTION SUMMARY
09/23/2022 Letter INSPECTION SUMMARY
11/01/2022 Letter INSPECTION SUMMARY
11/01/2022 Letter INSPECTION SUMMARY
01/20/2023 Letter INSPECTION SUMMARY
01/25/2023 CB-26 PATIO PIERS
04/11/2023 Letter INSPECTION SUMMARY
04/11/2023 Letter INSPECTION SUMMARY
04/13/2023 Letter INSPECTION SUMMARY
04/13/2023 Letter INSPECTION SUMMARY
04/13/2023 Letter Field Certificate of Occupancy
04/13/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: