Permit Application Status

PRRES20221050


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20221050
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
03/21/2022
06/20/2022
09/18/2022
11/12/2024
Locations
Contacts
SPELLERBERG ENTERPRISES LLC, Address:613 NE VIEWPARK DR, Phone:(816) 550-5535  
Billy Spellerberg, Address:613 ne viewpark dr  
SPELLERBERGENTERPRISES@GMAIL.COM  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
NEW HEIGHTS ELECTRIC LLC, Address:P O BOX 163, Phone:(816) 625-9504  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
  
  
  
  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $570.00 $570.00 Paid 06/20/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 06/20/2022
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/20/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 06/20/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 06/20/2022
9110078-Valuation Fee New Single Family $1,338.03 $1,338.03 Paid 06/20/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/23/2022 6/23/2022 06/23/2022
Sewer Service Inspection - R Passed 7/19/2022 (11:15) 7/19/2022 07/19/2022
Underslab Plumbing Inspection - Residential Passed 7/20/2022 7/19/2022 07/19/2022
Water Service Inspection - R Partial 7/19/2022 07/19/2022
Misc
Informational
07/19/2022
pex ran from foundation
Water Service Inspection - R Passed 7/20/2022 (10:45) 7/20/2022 07/20/2022
Misc
Resolved
07/20/2022
pex ran from foundation
Piers/Caissons Inspection - Residential Passed 9/19/2022 (11:15) 9/19/2022 09/19/2022
All Rough Inspection - Residential Failed 10/14/2022 10/14/2022 10/14/2022
Misc
Corrective Action Required
10/14/2022
exterior nailing for lap siding areas all okay to cover except bedroom above dining cover patio and covered deck inspected
All Rough Inspection - Residential Failed 10/18/2022 10/18/2022 10/18/2022
Misc
Informational
10/18/2022
2nd inspection exterior nailing for lap siding areas all okay to cover cover patio and covered deck inspected
Gas Service Inspection - Residential Passed 2/15/2023 2/15/2023 02/15/2023
Electrical Service Inspection Passed 2/15/2023 2/15/2023 02/15/2023
All Rough Inspection - Residential Failed 2/15/2023 2/15/2023 02/15/2023
Misc
Informational
10/18/2022
2nd inspection exterior nailing for lap siding areas all okay to cover cover patio and covered deck inspected
Misc
Corrective Action Required
02/15/2023
- Fb end of soffit at back of single garage bay - Support hip rafter at single garage at LVL - Anchor bolt for PFH portal frame to be in middle third of plate - Ductwork for main floor bathroom vent to 4”, 3” not allowed - Missing nails in joist hanger at great room , I-beam by ductwork - Fb gap in floor near B-vent at main floor - Fb penetration at top plate at front door - Missing nails joist hanger first floor at fireplace near stairs - Missing joists hangers above stairs landing second floor - Solid block notches cut into sidings below top plate into soffit throughout second floor - Purlin struts to be 48” OC - Bathroom vent ductwork to be 4” second floor - Pan off return air northwest bedroom - Exterior corners require minimum of 3 studs, address both cripple walls in basement - Fb basement bedroom fur out vertical to horizontal - Fb basement bedroom vertical every 10’ - Tighten anchor bolts in basement - Basement bathroom vent ductwork to be 4”
All Rough Inspection - Residential Passed 2/23/2023 2/23/2023 02/23/2023
Misc
Informational
02/15/2023
2nd inspection exterior nailing for lap siding areas all okay to cover cover patio and covered deck inspected
Misc
Resolved
02/23/2023
- Fb end of soffit at back of single garage bay - Support hip rafter at single garage at LVL - Anchor bolt for PFH portal frame to be in middle third of plate - Ductwork for main floor bathroom vent to 4”, 3” not allowed - Missing nails in joist hanger at great room , I-beam by ductwork - Fb gap in floor near B-vent at main floor - Fb penetration at top plate at front door - Missing nails joist hanger first floor at fireplace near stairs - Missing joists hangers above stairs landing second floor - Solid block notches cut into sidings below top plate into soffit throughout second floor - Purlin struts to be 48” OC - Bathroom vent ductwork to be 4” second floor - Pan off return air northwest bedroom - Exterior corners require minimum of 3 studs, address both cripple walls in basement - Fb basement bedroom fur out vertical to horizontal - Fb basement bedroom vertical every 10’ - Tighten anchor bolts in basement - Basement bathroom vent ductwork to be 4”
Erosion Control Inspection Residential Failed 8/18/2023 08/18/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/18/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS Maintain downed silt fence
Driveway Inspection Partial 11/15/2023 11/15/2023 11/15/2023
Misc
Informational
11/15/2023
11-15-23 Dustin A, DW is formed. Aggregate is compacted and depths are in compliance . Will need to maintain ADA specs through approach. Approved to pour.
Sidewalk Inspection Partial 11/16/2023 11/16/2023 11/15/2023
Sidewalk Inspection Partial 11/15/2023 11/15/2023
Driveway Inspection Partial 11/16/2023 11/16/2023 11/15/2023
Misc
Informational
11/15/2023
11-15-23 Dustin A, DW is formed. Aggregate is compacted and depths are in compliance . Will need to maintain ADA specs through approach. Approved to pour.
Sidewalk Inspection Partial 11/22/2023 11/22/2023 11/22/2023
Misc
Corrective Action Required
12/18/2023
11-22-23 Dustin A, Sw is formed and aggregate is compacted. Slopes are in compliance. Aprroved to pour. 12-18-23 Dustin A, sw still needs white cure added.
Driveway Inspection Passed 11/28/2023 11/28/2023 11/28/2023
Misc
Informational
11/15/2023
11-15-23 Dustin A, DW is formed. Aggregate is compacted and depths are in compliance . Will need to maintain ADA specs through approach. Approved to pour. 11-28-23 Dustin A, DW is poured, slopes are in compliance . Passed
Sidewalk Inspection Partial 11/29/2023 11/29/2023 12/18/2023
Misc
Corrective Action Required
12/18/2023
11-22-23 Dustin A, Sw is formed and aggregate is compacted. Slopes are in compliance. Aprroved to pour. 11-28-23 Dustin A, sw is poured, slopes are in compliance and forms are pulled. 12-18-23 Dustin A, White cure still needs added
Sidewalk Inspection Partial 12/27/2023 12/27/2023 12/27/2023
Misc
Corrective Action Required
12/18/2023
11-22-23 Dustin A, Sw is formed and aggregate is compacted. Slopes are in compliance. Aprroved to pour. 11-28-23 Dustin A, sw is poured, slopes are in compliance and forms are pulled. 12-18-23 Dustin A, White cure still needs added 12-27-23 Dustin A, conditions have not changed
Sidewalk Inspection Partial 1/4/2024 1/4/2024 01/04/2024
Misc
Corrective Action Required
12/27/2023
11-22-23 Dustin A, Sw is formed and aggregate is compacted. Slopes are in compliance. Aprroved to pour. 11-28-23 Dustin A, sw is poured, slopes are in compliance and forms are pulled. 12-18-23 Dustin A, White cure still needs added 12-27-23 Dustin A, conditions have not changed 1-4-24 Dustin A, Conditions have not changed
Sidewalk Inspection Failed 1/26/2024 1/26/2024 01/29/2024
Misc
Corrective Action Required
01/04/2024
11-22-23 Dustin A, Sw is formed and aggregate is compacted. Slopes are in compliance. Aprroved to pour. 11-28-23 Dustin A, sw is poured, slopes are in compliance and forms are pulled. 12-18-23 Dustin A, White cure still needs added 12-27-23 Dustin A, conditions have not changed 1-29-24 Dustin A, white cure was not added correctly. Discussed with jeremy with precision flatwork. SW will need to be torn out and replaced and white cure added per city specs. New pre pour inspection will need to be recalled in Fail
Erosion Control Inspection Residential Failed 2/7/2024 02/07/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/18/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS Maintain downed silt fence
Sidewalk Inspection Passed 3/25/2024 3/25/2024 03/28/2024
Misc
Corrective Action Required
01/29/2024
11-22-23 Dustin A, Sw is formed and aggregate is compacted. Slopes are in compliance. Aprroved to pour. 11-28-23 Dustin A, sw is poured, slopes are in compliance and forms are pulled. 12-18-23 Dustin A, White cure still needs added 12-27-23 Dustin A, conditions have not changed 1-29-24 Dustin A, white cure was not added correctly. Discussed with jeremy with precision flatwork. SW will need to be torn out and replaced and white cure added per city specs. New pre pour inspection will need to be recalled in Fail 3-25-24 Dustin A, All panels have been pulled out to start over. SW is framed and compacted to city specs. approved to pour 3-28-24 Dustin A, SW is poured to city specs. Forms pulled . Passed
Sidewalk Inspection Passed 4/1/2024 4/1/2024 04/01/2024
Misc
Corrective Action Required
03/25/2024
11-22-23 Dustin A, Sw is formed and aggregate is compacted. Slopes are in compliance. Aprroved to pour. 11-28-23 Dustin A, sw is poured, slopes are in compliance and forms are pulled. 12-18-23 Dustin A, White cure still needs added 12-27-23 Dustin A, conditions have not changed 1-29-24 Dustin A, white cure was not added correctly. Discussed with jeremy with precision flatwork. SW will need to be torn out and replaced and white cure added per city specs. New pre pour inspection will need to be recalled in Fail 3-25-24 Dustin A, All panels have been pulled out to start over. SW is framed and compacted to city specs. approved to pour 4-1-24 Dustin A, Sw poured to city specs, Passed
Plot Plan Inspection Passed 08/22/2024
Erosion Control Inspection Residential Passed 08/22/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
08/22/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS Maintain downed silt fence
Occupancy Inspection - Codes Residential Failed 8/22/2024 8/22/2024 08/22/2024
Misc
Corrective Action Required
08/22/2024
-address to be properly illuminated -outlet in pantry to be GFCI protected -garage door to be self closing and latching -label breaker panel -security light at rear of home required -obtain issued lawn irrigation permit
Occupancy Inspection - Codes Residential Failed 11/8/2024 11/8/2024 11/08/2024
Misc
Corrective Action Required
08/22/2024
Washer circuit to be afci and gfci protected
Occupancy Inspection - Codes Residential Full C of O 11/12/2024 11/12/2024 11/12/2024
Misc
Resolved
11/12/2024
Washer circuit to be afci and gfci protected
Documents & Images
Date Uploaded File Type Document Name
03/21/2022 SVF 95-LSMO
03/22/2022 Permit Codes Residential Plan Review
03/28/2022 Approved Plans APPROVED PLANS
03/28/2022 Plot Plan APPROVED PLOT PLAN
03/28/2022 Permit Codes Residential Plan Review
06/20/2022 Permit DS Building Permit
06/20/2022 Receipt Receipt for transaction:2022-004869
06/23/2022 Letter INSPECTION SUMMARY
07/19/2022 Letter INSPECTION SUMMARY
07/19/2022 Letter INSPECTION SUMMARY
07/19/2022 Letter INSPECTION SUMMARY
07/20/2022 Letter INSPECTION SUMMARY
10/14/2022 Letter INSPECTION SUMMARY
10/18/2022 Letter INSPECTION SUMMARY
02/15/2023 Letter INSPECTION SUMMARY
02/15/2023 Letter INSPECTION SUMMARY
02/15/2023 Letter INSPECTION SUMMARY
02/23/2023 Letter INSPECTION SUMMARY
02/23/2023 Letter INSPECTION SUMMARY
02/23/2023 Letter INSPECTION SUMMARY
02/23/2023 Letter INSPECTION SUMMARY
02/23/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
11/15/2023 Letter INSPECTION SUMMARY
11/15/2023 Letter INSPECTION SUMMARY
11/15/2023 Letter INSPECTION SUMMARY
11/15/2023 Letter INSPECTION SUMMARY
11/15/2023 Letter INSPECTION SUMMARY
11/15/2023 Letter INSPECTION SUMMARY
11/21/2023 Letter INSPECTION SUMMARY
11/21/2023 Letter INSPECTION SUMMARY
11/22/2023 Letter INSPECTION SUMMARY
11/28/2023 Letter INSPECTION SUMMARY
11/28/2023 Letter INSPECTION SUMMARY
11/28/2023 Letter INSPECTION SUMMARY
11/28/2023 Letter INSPECTION SUMMARY
11/28/2023 Letter INSPECTION SUMMARY
12/18/2023 Letter INSPECTION SUMMARY
12/18/2023 Letter INSPECTION SUMMARY
12/18/2023 Letter INSPECTION SUMMARY
12/27/2023 Letter INSPECTION SUMMARY
12/27/2023 Letter INSPECTION SUMMARY
12/27/2023 Letter INSPECTION SUMMARY
12/27/2023 Letter INSPECTION SUMMARY
12/27/2023 Letter INSPECTION SUMMARY
01/04/2024 Letter INSPECTION SUMMARY
01/04/2024 Letter INSPECTION SUMMARY
01/04/2024 Letter INSPECTION SUMMARY
01/04/2024 Letter INSPECTION SUMMARY
01/04/2024 Letter INSPECTION SUMMARY
01/04/2024 Letter INSPECTION SUMMARY
01/04/2024 Letter INSPECTION SUMMARY
01/29/2024 Letter INSPECTION SUMMARY
02/07/2024 Letter INSPECTION SUMMARY
03/25/2024 Letter INSPECTION SUMMARY
03/28/2024 Letter INSPECTION SUMMARY
04/01/2024 Letter INSPECTION SUMMARY
04/01/2024 Letter INSPECTION SUMMARY
04/01/2024 Letter INSPECTION SUMMARY
04/01/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter Codes 140 Day Letter
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/22/2024 Letter INSPECTION SUMMARY
08/22/2024 Letter INSPECTION SUMMARY
08/22/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter Field Certificate of Occupancy
11/12/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home