Permit Application Status

PRRES20220859


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220859
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO STOP WORK ORDER generated on 06/08/2022 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 06/10/2022 12:00 AM by username 'Mitchell Schwarz'.
03/08/2022
03/09/2022
03/02/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
THAD@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,033.07 $1,033.07 Paid 03/09/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 03/09/2022
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 03/09/2022
8331507-Sewer Connection Fee $360.00 $360.00 Paid 03/09/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 03/09/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 03/09/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/09/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Not Ready 6/8/2022 6/8/2022 06/08/2022
Misc
Corrective Action Required
06/08/2022
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION
Footing Inspection - Residential Failed - Stop Work 6/8/2022 6/8/2022 06/08/2022
Misc
Corrective Action Required
06/08/2022
FOOTING POURED WITHOUT INSPECTION, UPLOAD ENGINEER REPORT TO PERMIT, FYI ENGINEER REPORT REQUIRED TO BE SUBMITTED WITHIN 48 HOURS OF INSPECTION
Underslab Plumbing Inspection - Residential Passed 6/10/2022 6/10/2022 06/10/2022
Misc
Corrective Action Required
06/08/2022
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION
Footing Inspection - Residential Passed 6/10/2022 06/10/2022
Misc
Resolved
06/10/2022
FOOTING POURED WITHOUT INSPECTION, UPLOAD ENGINEER REPORT TO PERMIT, FYI ENGINEER REPORT REQUIRED TO BE SUBMITTED WITHIN 48 HOURS OF INSPECTION
Misc
Informational
06/10/2022
third party footing inspection performed
Sewer Service Inspection - R Passed 6/14/2022 (8:00) 6/14/2022 06/14/2022
Water Service Inspection - R Passed 6/14/2022 (10:00) 6/14/2022 06/14/2022
Erosion Control Inspection Residential Failed 6/14/2022 6/14/2022 06/14/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/14/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Failed 9/15/2022 9/15/2022 09/15/2022
Misc
Corrective Action Required
09/15/2022
-tighten panel bonding screw at service panel
Gas Service Inspection - Residential Passed 9/15/2022 9/15/2022 09/15/2022
All Rough Inspection - Residential Failed 9/15/2022 9/15/2022 09/15/2022
Misc
Corrective Action Required
09/15/2022
-seal all top plate penetrations - see garage, 1st floor bath -fireblock plumbing chase garage -fireblock dryer duct garage wall -top plate corner lap connection per code at garage -min 24” lap between dbl top plate breaks - see master closet/garage wall, front bedroom -secure NM master closet wall per code -fireblock fireplace -land NM to box at great room wall -install sliding glass door -land NM to box at kitchen wall -secure all NM per code at kitchen -LIB strap cut for HVAC at kitchen -address top plate corner lap connection at front entry wall -solid block all sheathing breaks -support ridge both ends at covered porch -address rafters landing on blocks above top plate at covered porch -provide ridge straps at front covered porch per plans -provide H2.5 truss hold down clip at front bed -provide (2) nails each stud/top and bottom plate LIB metal straps per plans -seal HVAC plate penetration- see laundry, kitchen, master water closet -all truss lateral bracing per plans -provide joist hangers at header above furnace -tighten panel bonding screw at service panel -land NM to box at basement stairs, covered patio
Electrical Service Inspection Passed 9/27/2022 9/27/2022 09/27/2022
Misc
Resolved
09/27/2022
All Rough Inspection - Residential Failed 9/27/2022 9/27/2022 09/27/2022
Misc
Corrective Action Required
09/15/2022
-seal all top plate penetrations - see garage, 1st floor bath, kitchen -fireblock plumbing chase garage -fireblock dryer duct garage wall -secure all NM per code at kitchen, basement (secure within 8” of box) -support ridge both ends at covered porch -provide ridge straps at front covered porch per plans -provide H2.5 hold downs all rafters and 6” truss screws at covered porch rafters on blocks per engineer letter
Erosion Control Inspection Residential Partial 9/27/2022 9/27/2022 09/27/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
09/27/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Passed 10/4/2022 10/4/2022 10/04/2022
Misc
Resolved
10/04/2022
Driveway Inspection Passed 11/22/2022 11/22/2022
Misc
Informational
11/22/2022
On Tuesday, 11-22-2022. I performed and passed a driveway inspection for concrete placement.
Piers/Caissons Inspection - Residential Passed 01/20/2023
Misc
Informational
01/20/2023
- INSPECTION PERFORMED BY THIRD PARTY
Occupancy Inspection - Codes Residential Failed 1/20/2023 1/20/2023 01/20/2023
Misc
Corrective Action Required
01/20/2023
- INSPECTION DENIED NO ADDRESS POSTED
Occupancy Inspection - Codes Residential Failed 2/6/2023 2/6/2023 02/06/2023
Misc
Corrective Action Required
01/20/2023
- Outlet on front porch not GFCI protected - Provide spindles at garage handrail - Label non- GFCI outlets - Open electrical box over fireplace - Seal exterior penetrations - Seal above A/C disconnect - Seal above light fixtures at garage - Sump discharge to be 36” away from foundation - Provide splash pads - Install back flow preventer at spigot by water main - Raise water meter pit to grade and meter to be 14”-18” from rim of pit.
Erosion Control Inspection Residential Failed 2/6/2023 02/06/2023
Misc
Corrective Action Required
02/06/2023
-Erosion control to remain in place until sod is in . - Clean debris and gravel from street - Clean storm inlet
Erosion Control Inspection Residential Passed 03/02/2023
Misc
Resolved
03/02/2023
-Erosion control to remain in place until sod is in . - Clean debris and gravel from street - Clean storm inlet
Plot Plan Inspection Passed 03/02/2023
Occupancy Inspection - Codes Residential Full C of O 3/2/2023 3/2/2023 03/02/2023
Misc
Resolved
03/02/2023
- Outlet on front porch not GFCI protected - Provide spindles at garage handrail - Label non- GFCI outlets - Open electrical box over fireplace - Seal exterior penetrations - Seal above A/C disconnect - Seal above light fixtures at garage - Sump discharge to be 36” away from foundation - Provide splash pads - Install back flow preventer at spigot by water main - Raise water meter pit to grade and meter to be 14”-18” from rim of pit.
Documents & Images
Date Uploaded File Type Document Name
03/08/2022 CB #13 - Permit App
03/09/2022 Approved Plans Approved Drawings
03/09/2022 Approved Plans Approved Roof Truss Layout
03/09/2022 Approved Plans Approved Truss Package
03/09/2022 Engineer Report/Study Cobey Creek Lots 1-7 and 13-29 Engineer letter
03/09/2022 Plot Plan Approved Plot Plan
03/09/2022 Permit Codes Residential Plan Review
03/09/2022 Permit DS Building Permit
03/09/2022 Receipt Receipt for transaction:2022-001264
06/08/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter Stop Work Order
06/09/2022 Receipt Receipt for transaction:2022-004488
06/09/2022 13 Cobey Creek Subgrade (corrected)
06/09/2022 13 Cobey Creek Subgrade reinspection (corrected)
06/10/2022 13 Cobey Creek FTNG
06/10/2022 Letter INSPECTION SUMMARY
06/10/2022 Letter INSPECTION SUMMARY
06/14/2022 Letter INSPECTION SUMMARY
06/14/2022 Letter INSPECTION SUMMARY
06/14/2022 Letter INSPECTION SUMMARY
08/25/2022 CB 13 -Engineering Letter - Omitted Embedded Holddown Device
08/26/2022 CB 13 -Engineering Letter - Omitted Embedded Holddown Device
08/29/2022 Strong-Drive® SDWC TRUSS PT3
09/15/2022 Letter INSPECTION SUMMARY
09/15/2022 Letter INSPECTION SUMMARY
09/15/2022 Letter INSPECTION SUMMARY
09/24/2022 CB 13 - Rafters Landing at covered patio - Engineering Letter
09/27/2022 Letter INSPECTION SUMMARY
09/27/2022 Letter INSPECTION SUMMARY
09/27/2022 Letter INSPECTION SUMMARY
10/04/2022 Letter INSPECTION SUMMARY
11/22/2022 Letter INSPECTION SUMMARY
01/20/2023 Letter INSPECTION SUMMARY
01/20/2023 Letter INSPECTION SUMMARY
02/06/2023 Letter INSPECTION SUMMARY
02/06/2023 Letter INSPECTION SUMMARY
03/02/2023 Letter INSPECTION SUMMARY
03/02/2023 Letter INSPECTION SUMMARY
03/02/2023 Letter Field Certificate of Occupancy
03/02/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home