Summary
PRRES20220625
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINSIHED BASEMENT - UNCOVERED DECK STOP WORK ORDER generated on 07/11/2022 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 07/14/2022 12:00 AM by username 'Mitchell Schwarz'.
02/18/2022
03/16/2022
08/22/2022
01/26/2024
Locations
Contacts
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
Jennifer Pestka, Address:p o box 6423  
JENNIFER@IQHOMEBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $540.00 $540.00 Paid 03/16/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 03/16/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 03/16/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 03/16/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 03/16/2022
9110078-Valuation Fee New Single Family $1,323.74 $1,323.74 Paid 03/16/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 02/07/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 02/28/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/22/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/27/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Not Ready 5/23/2022 5/23/2022 05/23/2022
Misc
Corrective Action Required
05/23/2022
interior drain tile not installed correctly
Sewer Service Inspection - R Passed 5/23/2022 (9:30) 5/23/2022 05/23/2022
Water Service Inspection - R Passed 5/23/2022 (3:30) 5/23/2022 05/23/2022
Underslab Plumbing Inspection - Residential Failed 7/7/2022 7/7/2022 07/07/2022
Misc
Corrective Action Required
05/23/2022
inspection denied for erosion control at the front of the lot, over grown vegitation.
Underslab Plumbing Inspection - Residential Failed 7/11/2022 7/11/2022 07/11/2022
Misc
Corrective Action Required
07/07/2022
inspection denied for erosion control at the front of the lot, over grown vegitation.
Misc
Corrective Action Required
07/11/2022
inspection denied footing poured without inspection
Footing Inspection - Residential Failed - Stop Work 7/11/2022 07/11/2022
Misc
Corrective Action Required
07/11/2022
footing poured without inspection. stop work issued provide third party inspection report.
Underslab Plumbing Inspection - Residential Failed 7/14/2022 7/14/2022 07/14/2022
Misc
Resolved
07/14/2022
inspection denied for erosion control at the front of the lot, over grown vegitation.
Misc
Corrective Action Required
07/14/2022
inspection denied footing poured without inspection
Footing Inspection - Residential Failed 7/14/2022 07/14/2022
Misc
Corrective Action Required
07/14/2022
footing poured without inspection. stop work issued provide third party inspection report. Third party inspection does not meet the requirements of the citys third party footing inspection report.
Footing Inspection - Residential Passed 7/22/2022 07/22/2022
Misc
Resolved
07/22/2022
footing poured without inspection. stop work issued provide third party inspection report. Third party inspection does not meet the requirements of the citys third party footing inspection report.
Underslab Plumbing Inspection - Residential Passed 7/22/2022 7/22/2022 07/22/2022
Misc
Resolved
07/22/2022
inspection denied footing poured without inspection
Piers/Caissons Inspection - Residential Passed 10/17/2022 (10:30) 10/17/2022 10/17/2022
Misc
Informational
10/17/2022
deck piers good
Electrical Service Inspection Not Ready 2/9/2023 2/9/2023 02/09/2023
Misc
Corrective Action Required
02/09/2023
Complete service install Bond service panel
Gas Service Inspection - Residential Failed 2/9/2023 2/9/2023 02/09/2023
Misc
Corrective Action Required
02/09/2023
Bond gas line pressure OK
Erosion Control Inspection Residential Failed 2/9/2023 02/09/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/09/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Failed 2/9/2023 2/9/2023 02/09/2023
Misc
Corrective Action Required
02/09/2023
MAINTAIN EROSION CONTROL -provide attic access above garage -fire block wall space to ceiling space at dwv garage W wall -fire block hvac chase in garage entry coat closet to ceiling space -block stud space to under floor ceiling space at stairs and great room -address s3.2 10 strapping at deck -missing nails in triple lvl hanger above fridge both ends -seal floor and top plate penetration and gaps at kitchen S wall -seal penetrations in R/a joist space above kitchen S wall -missing stud pack NE breakfast area -nail all exterior wall corners together together to code -seal bottom plate penetration in bed 3 closet -seal top plate penetration in master shower -provide joist hangers for ceiling joists above master bath -seal bed space at master bed entry -2 king studs at stairwell window per plans -complete and bond electrical service for install for inspection -address over notched 2x6 stud at NW basement -anchor bolts in basement to be in the middle 1/3 of sill plate and tight -missing double floor joist under kitchen in basement -missing stud back E wall in basement Missing double floor joist above SE basement corner -fire block stairwell walls to under floor landing space -missing stud pack at stairwell wall in basement under beam -sold block cantilevers in basement -solid block above Ibeam in basement -solid block joist spaces running parallel to foundation 2joist spaces in 4’ OC
Gas Service Inspection - Residential Passed 3/1/2023 3/1/2023 03/01/2023
Misc
Resolved
03/01/2023
Bond gas line pressure OK
Electrical Service Inspection Passed 3/1/2023 3/1/2023 03/01/2023
Misc
Resolved
03/01/2023
Complete service install Bond service panel
All Rough Inspection - Residential Failed 3/1/2023 3/1/2023 03/01/2023
Misc
Corrective Action Required
02/09/2023
-provide attic access above garage(protect nm within 6’ of attic access) -address s3.2 10 strapping at deck (uncover at deck to show attachment) -missing stud pack NE Breakfast area(3 jack studs) -provide joist hangers for ceiling joists above master bath(missing nail) -anchor bolts in basement to be in the middle 1/3 of sill plate and tight not completed -Missing double floor joist above SE basement corner
All Rough Inspection - Residential Failed 3/3/2023 3/3/2023 03/03/2023
Misc
Corrective Action Required
03/01/2023
-anchor bolts in basement to be in the middle 1/3 of sill plate and tight not completed (see south east corner.
All Rough Inspection - Residential Passed 3/7/2023 3/7/2023 03/07/2023
Misc
Resolved
03/07/2023
-anchor bolts in basement to be in the middle 1/3 of sill plate and tight not completed (see south east corner.
Sidewalk Inspection Not Ready 5/4/2023 5/4/2023 05/04/2023
Misc
Informational
05/04/2023
5-4-23 RH. Rock was not in place for sidewalk.
Driveway Inspection Partial 5/4/2023 5/4/2023 05/04/2023
Misc
Informational
05/04/2023
5-4-23 RH. Driveway is fromed up and aggregate is placed and compacted. Approved to pour.
Driveway Inspection Passed 5/11/2023 5/11/2023 05/12/2023
Misc
Informational
05/04/2023
5-4-23 RH. Driveway is fromed up and aggregate is placed and compacted. Approved to pour. 5-12-23 RH. Driveway meets LS and ADA specification.
Sidewalk Inspection Passed 5/12/2023 05/12/2023
Misc
Informational
05/12/2023
5-4-23 RH. Sidewalkj is formed up and aggreagate is placed and compacted. 5-12-23 RH. Sidewalk meets LS and ADA specificaiton.
Erosion Control Inspection Residential Failed 7/20/2023 07/20/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
07/20/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/20/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Establish silt fence and maintain overgrown vegetation
Plot Plan Inspection Passed 12/21/2023
Occupancy Inspection - Codes Residential Failed 12/21/2023 12/21/2023 12/21/2023
Misc
Corrective Action Required
12/21/2023
-Pay all fees -obtain issued lawn irrigation permit -stair risers at front stoop shall not be greater that 3/8 difference in rise -label all non GFCI outlets in unfinished spaces -address handrail continuity in garage -guard rail at deck spacing for spindles must not be greater that 4” -spark ring for outlet in master bathroom -afci protection for all kitchen circuits -Secure service entry cable at panel -set screw installed and sheared off at water anti-siphon device -secondary locking device at rear slider -address siding from grade at rear of lot -splash blocks to extend 36 inches from foundation -deck posts over notched for deck post to beam connection
Erosion Control Inspection Residential Passed 12/27/2023 12/27/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
12/27/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Establish silt fence and maintain overgrown vegetation
Occupancy Inspection - Codes Residential Failed 12/27/2023 12/27/2023 12/27/2023
Misc
Corrective Action Required
12/21/2023
-splash blocks to extend 36 inches from foundation -deck posts over notched for deck post to beam connection
Occupancy Inspection - Codes Residential Ready for Temp CO 12/27/2023 12/27/2023
Misc
Corrective Action Required
12/27/2023
-splash blocks to extend 36 inches from foundation -deck posts over notched for deck post to beam connection
Occupancy Inspection - Codes Residential Full C of O 1/26/2024 01/26/2024
Misc
Resolved
01/26/2024
-splash blocks to extend 36 inches from foundation -deck posts over notched for deck post to beam connection
Documents & Images
Date Uploaded File Type Document Name
02/23/2022 Permit Codes Residential Plan Review
02/23/2022 2018 SW Red Barn Ln - Permit Application
02/24/2022 Plot Plan APPROVED PLOT PLAN
03/02/2022 Approved Plans APPROVED PLANS
03/02/2022 Permit Codes Residential Plan Review
03/16/2022 Permit DS Building Permit
03/16/2022 Receipt Receipt for transaction:2022-001431
05/23/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter INSPECTION SUMMARY
07/07/2022 Letter INSPECTION SUMMARY
07/11/2022 Letter INSPECTION SUMMARY
07/11/2022 Letter Stop Work Order
07/12/2022 2018 SW RED BARN LN FTG INSP
07/14/2022 Letter INSPECTION SUMMARY
07/18/2022 2018 SW RED BARN LN FOOTING LSMO
07/21/2022 2018 SW RED BARN LANE FTG REV2
07/21/2022 Letter INSPECTION SUMMARY
07/22/2022 Letter INSPECTION SUMMARY
07/22/2022 Letter INSPECTION SUMMARY
02/07/2023 Receipt Receipt for transaction:2023-000734
02/09/2023 Letter INSPECTION SUMMARY
02/09/2023 Letter INSPECTION SUMMARY
02/09/2023 Letter INSPECTION SUMMARY
02/09/2023 Letter INSPECTION SUMMARY
02/09/2023 Letter INSPECTION SUMMARY
02/28/2023 Receipt Receipt for transaction:2023-001139
03/01/2023 Letter INSPECTION SUMMARY
03/01/2023 Letter INSPECTION SUMMARY
03/01/2023 Letter INSPECTION SUMMARY
03/03/2023 Letter INSPECTION SUMMARY
03/07/2023 Letter INSPECTION SUMMARY
05/04/2023 Letter INSPECTION SUMMARY
05/04/2023 Letter INSPECTION SUMMARY
05/12/2023 Letter INSPECTION SUMMARY
05/12/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
12/07/2023 Letter Codes 140 Day Letter
12/21/2023 Letter INSPECTION SUMMARY
12/21/2023 Letter INSPECTION SUMMARY
12/22/2023 Receipt Receipt for transaction:2023-009283
12/27/2023 Letter INSPECTION SUMMARY
12/27/2023 Letter INSPECTION SUMMARY
12/27/2023 Certificate/License Codes Temporary Certificate of Occupancy
12/27/2023 Receipt Receipt for transaction:2023-009313
01/26/2024 Letter Field Certificate of Occupancy
01/26/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home