Summary
PRRES20220523
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - UNCOVERED DECK
02/10/2022
02/11/2022
08/10/2022
01/24/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
TAYLOR@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,224.38 $1,224.38 Paid 02/11/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 02/11/2022
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 02/11/2022
8331507-Sewer Connection Fee $450.00 $450.00 Paid 02/11/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 02/11/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 02/11/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 01/23/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/7/2022 3/7/2022 03/07/2022
Misc
Corrective Action Required
03/07/2022
APPROVED PER DAVID P AINSWORTH 3/1/22
Underslab Plumbing Inspection - Residential Failed 3/17/2022 3/17/2022 03/17/2022
Misc
Corrective Action Required
03/17/2022
BACKFILL AT FOUNDATION TO ALLOW FOR INSPECTION
Underslab Plumbing Inspection - Residential Passed 3/23/2022 3/23/2022 03/23/2022
Misc
Resolved
03/23/2022
BACKFILL AT FOUNDATION TO ALLOW FOR INSPECTION
Sewer Service Inspection - R Passed 4/6/2022 (9:30) 4/6/2022 04/06/2022
Water Service Inspection - R Passed 4/12/2022 (9:45) 4/12/2022 04/12/2022
Electrical Service Inspection Passed 11/1/2022 11/1/2022 11/01/2022
Gas Service Inspection - Residential Passed 11/1/2022 11/1/2022 11/01/2022
All Rough Inspection - Residential Failed 11/1/2022 11/1/2022 11/01/2022
Misc
Corrective Action Required
11/01/2022
-Engineer letter concerning condition of weathered trusses need to be specific for this address and permit -fireblock HVAC chase at garage wall -address overbored floor joist for DWV above garage entry -provide attic ventilation at sgl car garage -anchor steel column at garage to floor -support DWV every 48” oc, traps not considered support -provide (2) nails each intersecting studs and plates of LIB straps -nail all intersecting corners of braced wall panels 12” oc -provide bocca protection plate at DWV furred down soffit line 1st floor bath -fireblock HVAC chase at pantry -nail off all joist hangers -fireblock HVAC chase 2nd floor hall -master bed windows CS-PF portal bracing per plans, construction does not match design, see plans/IRC R602.10.6.4 -provide hanger HGUS26-2 at B4 girder per plans -nail king studs to header at basement windows -provide anchor bolts within 12” of plate break at basement -header overbored for DWV above basement egress window -address (9) floor joists near service panel at basement that have bores for NM less than 2” apart -solid block between joists every 48” oc at kitchen island per plans -provide metal straps at CS-PF header to trimmer studs at basement windows per design
All Rough Inspection - Residential Passed 11/4/2022 11/4/2022 11/04/2022
Misc
Resolved
11/04/2022
Driveway Inspection Partial 1/3/2023 1/3/2023 01/03/2023
Misc
Informational
01/03/2023
1-3-23 RH. Driveway is formed up and aggregate is placed and compacted. Spoke with foreman about expansion joints. Approved to pour.
Driveway Inspection Passed 1/10/2023 1/10/2023 01/10/2023
Misc
Informational
01/03/2023
1-3-23 RH. Driveway is formed up and aggregate is placed and compacted. Spoke with foreman about expansion joints. Approved to pour. 1-10-23 RH Driveway meets LS specification.
Erosion Control Inspection Residential Failed 4/11/2023 04/11/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/11/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Piers/Caissons Inspection - Residential Failed 4/24/2023 4/24/2023 04/24/2023
Miscellaneous Correction
Corrective Action Required
04/24/2023
Pier holes at the bottom of the patio stairs are only 11 and 15 inches deep.
Piers/Caissons Inspection - Residential Passed 4/24/2023 04/24/2023
Miscellaneous Correction
Corrective Action Required
04/24/2023
Pier holes at the bottom of the patio stairs are only 11 and 15 inches deep.
Erosion Control Inspection Residential Passed 9/11/2023 09/11/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
09/11/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Plot Plan Inspection Passed 11/1/2023 11/01/2023
Occupancy Inspection - Codes Residential Not Ready 1/12/2024 1/12/2024 01/12/2024
Miscellaneous Correction
Corrective Action Required
01/12/2024
Interior handrails at stairs are not installed. Walk your property before scheduling inspections. Not ready for inspection. 01/11/23 KBEARD 9:05am
Occupancy Inspection - Codes Residential Failed 1/17/2024 1/17/2024 01/17/2024
Miscellaneous Correction
Resolved
01/17/2024
Interior handrails at stairs are not installed. Walk your property before scheduling inspections. Not ready for inspection. 01/11/23 KBEARD 9:05am
Miscellaneous Correction
Corrective Action Required
01/17/2024
3526 SE Corbin Occupancy Inspection -Garage to house door self closing hinge is not pulling the door fully closed -Seal all boards at wall to ceiling in garage -Ufer in garage needs to be sealed so gasses do not enter the home -Corner in garage to house needs to be sealed so gasses do not enter the home -Garage to house steps have a greater than 3/8 of an inch difference in riser height Back patio door does not latch and lock -First step up in the entry to upstairs has a riser height to 8 3/16 of an inch. Allowable height is no greater than 7 3/4 of an inch -Bottom step in the stairwell to the basement has a 8 inch riser height. IRC requires a height of no more than a 7 3/4 of an inch in riser height -Seal all exterior penetrations
Occupancy Inspection - Codes Residential Full C of O 1/24/2024 1/24/2024 01/24/2024
Miscellaneous Correction
Resolved
01/24/2024
3526 SE Corbin Occupancy Inspection -Garage to house door self closing hinge is not pulling the door fully closed -Seal all boards at wall to ceiling in garage -Ufer in garage needs to be sealed so gasses do not enter the home -Corner in garage to house needs to be sealed so gasses do not enter the home -Garage to house steps have a greater than 3/8 of an inch difference in riser height Back patio door does not latch and lock -First step up in the entry to upstairs has a riser height to 8 3/16 of an inch. Allowable height is no greater than 7 3/4 of an inch -Bottom step in the stairwell to the basement has a 8 inch riser height. IRC requires a height of no more than a 7 3/4 of an inch in riser height -Seal all exterior penetrations
Documents & Images
Date Uploaded File Type Document Name
02/10/2022 CB #158 - PERMIT APPLICATION
02/10/2022 CB #158 -REVISED Basswood - Farmhouse ELEV 2 - Sheets - Signed - Flattened
02/10/2022 Approved Plans Approved Drawings
02/10/2022 Approved Plans Approved Truss Layout
02/10/2022 Approved Plans Approved Truss Package
02/11/2022 Permit Codes Residential Plan Review
02/11/2022 Plot Plan Approved Plot Plan
02/11/2022 Permit Codes Residential Plan Review
02/11/2022 Permit DS Building Permit
02/11/2022 Receipt Receipt for transaction:2022-000771
03/02/2022 M L Crose 3526 SE Corbin Dr LSMO Cobey Creek Lot 158 Clayton Permit 2022-0523 Footing Inspection Report 3-1-22
03/07/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
03/23/2022 Letter INSPECTION SUMMARY
03/23/2022 Letter INSPECTION SUMMARY
04/06/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
04/29/2022 Plans APPROVED TRUSS LAYOUT
10/31/2022 158 cobey creek truss letter- signed
10/31/2022 3008833 REPAIR SEALS 10272022 CB 158
11/01/2022 Letter INSPECTION SUMMARY
11/01/2022 Letter INSPECTION SUMMARY
11/01/2022 Letter INSPECTION SUMMARY
11/04/2022 158 cobey creek truss letter- signed
11/04/2022 158 Cobey Creek holes in header, hole in floor joist and CS-PF installation- signed
11/04/2022 158 Cobey Creek Holes in FJ- signed
11/04/2022 Letter INSPECTION SUMMARY
01/03/2023 Letter INSPECTION SUMMARY
01/10/2023 Letter INSPECTION SUMMARY
04/11/2023 Letter INSPECTION SUMMARY
04/24/2023 Letter INSPECTION SUMMARY
04/24/2023 Letter INSPECTION SUMMARY
09/11/2023 Letter INSPECTION SUMMARY
09/11/2023 Letter Codes 140 Day Letter
11/01/2023 Letter INSPECTION SUMMARY
01/12/2024 Letter INSPECTION SUMMARY
01/17/2024 Letter INSPECTION SUMMARY
01/23/2024 Receipt Receipt for transaction:2024-000363
01/24/2024 Letter Codes Final Certificate of Occupancy
01/24/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home