Summary
PRRES20220407
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
02/01/2022
02/07/2022
08/01/2022
12/14/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
THAD@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,364.68 $1,364.68 Paid 02/07/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 02/07/2022
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 02/07/2022
8331507-Sewer Connection Fee $510.00 $510.00 Paid 02/07/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 02/07/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 02/07/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/22/2022 02/22/2022
Underslab Plumbing Inspection - Residential Passed 3/17/2022 3/17/2022 03/17/2022
Sewer Service Inspection - R Passed 4/11/2022 (10:30) 4/11/2022 04/11/2022
Water Service Inspection - R Passed 4/12/2022 (9:00) 4/12/2022 04/12/2022
Electrical Service Inspection Passed 8/1/2022 8/1/2022 08/01/2022
Gas Service Inspection - Residential Failed 8/1/2022 8/1/2022 08/01/2022
Misc
Corrective Action Required
08/01/2022
-Gas pressure 0 psi, must maintain 10 psi for test
All Rough Inspection - Residential Failed 8/1/2022 8/1/2022 08/01/2022
Misc
Corrective Action Required
08/01/2022
-install all roof flashing boots at penetrations -complete fur downs and fur outs for plumbing at garage wall -seal all top and bottom plate penetrations - garage wall, kitchen, front bedroom, master bed -snow block at mud room -solid block between joists at mud/kitchen wall -2x8 joist hangers used on 2x10 joists, see joists at lvl great room and foyer -nail all joist hangers complete -solid block between joists at great room/bath and closet wall -fireblock fireplace -seal low volt at fireplace -12” oc nailing all abutting and intersecting corners -provide bocca plate protection bottom plate pex, 1st floor shower -provide protection plates for DWV master bath vanity -30” vertical clearance required at attic access master closet -protect all electrical within 6’ of attic entry -provide (4) 2x4 stud packs all girder truss bearing ends per plans -provide clamp to secure SE cable above service panel -Gas pressure 0 psi, must maintain 10 psi for test
All Rough Inspection - Residential Passed 8/17/2022 8/17/2022 08/17/2022
Misc
Resolved
08/17/2022
-2x8 joist hangers used on 2x10 joists, see joists at lvl great room and foyer -nail all joist hangers complete -solid block between joists at great room/bath and closet wall -fireblock fireplace -seal low volt at fireplace -12” oc nailing all abutting and intersecting corners -provide bocca plate protection bottom plate pex, 1st floor shower -provide protection plates for DWV master bath vanity -30” vertical clearance required at attic access master closet -protect all electrical within 6’ of attic entry -provide (4) 2x4 stud packs all girder truss bearing ends per plans -provide clamp to secure SE cable above service panel -Gas pressure 0 psi, must maintain 10 psi for test
Gas Service Inspection - Residential Passed 8/17/2022 8/17/2022 08/17/2022
Misc
Resolved
08/17/2022
-Gas pressure 0 psi, must maintain 10 psi for test
Driveway Inspection Partial 8/25/2022 8/25/2022 08/25/2022
Misc
Informational
08/25/2022
8-25-22 RH. Driveway is formed up and aggregate is placed and compacted.
Driveway Inspection Passed 9/1/2022 9/1/2022 08/29/2022
Misc
Informational
08/25/2022
8-25-22 RH. Driveway is formed up and aggregate is placed and compacted.
Misc
Informational
08/29/2022
On Monday, 8-29-2022. I performed a visual on a existing drive approach and found it to meet city standard.
Sidewalk Inspection Passed 8/31/2022 8/31/2022 08/31/2022
Misc
Informational
08/31/2022
On Wednesday, 8-31-2022 I performed and passed a sidewalk inspection for concrete placement.
Occupancy Inspection - Codes Residential Failed 11/22/2022 11/22/2022 11/22/2022
Misc
Corrective Action Required
11/22/2022
-no deck pier inspection performed -final grade and sod -splash blocks -set sewer tracer box to grade -seal all penetrations in siding -guardrail at front porch -tempered glass required at window 1st floor front bed within swing of closet door -label all dedicated outlets at garage/basement as not GFCI protected -GFCI protection at dishwasher outlet -provide support basement handrail, handrail must return at point above bottom rise of flight -AFCI protection at kit/dine and fridge circuits
Occupancy Inspection - Codes Residential Failed 12/12/2022 12/12/2022 12/12/2022
Misc
Corrective Action Required
11/22/2022
-provide an as graded plot plan for lot, concern at rear of lot with grade higher will not allow for drainage of lot at swale rear of lot -GFCI protection at dishwasher outlet, outlet testing as hot/ground reverse -AFCI protection at kit/dine circuit, breaker not tripping when test button pressed
Erosion Control Inspection Residential Passed 12/12/2022 12/12/2022 12/12/2022
Plot Plan Inspection Failed 12/12/2022 12/12/2022 12/12/2022
Misc
Corrective Action Required
12/12/2022
-provide an as graded plot plan for lot, concern at rear of lot with grade higher will not allow for drainage of lot at swale rear of lot
Occupancy Inspection - Codes Residential Full C of O 12/14/2022 12/14/2022 12/14/2022
Misc
Resolved
12/14/2022
Plot Plan Inspection Passed 12/14/2022 12/14/2022 12/14/2022
Misc
Resolved
12/14/2022
Documents & Images
Date Uploaded File Type Document Name
02/01/2022 CB #23 - PERMIT APPLICATION
02/01/2022 Approved Plans Approved Drawings
02/01/2022 Approved Plans Approved Truss Package
02/01/2022 Approved Plans Approved Truss Layout
02/02/2022 Permit Codes Residential Plan Review
02/07/2022 Plot Plan Approved Plot Plan
02/07/2022 Permit Codes Residential Plan Review
02/07/2022 Permit DS Building Permit
02/07/2022 Receipt Receipt for transaction:2022-000639
02/22/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
04/11/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
08/01/2022 Letter INSPECTION SUMMARY
08/01/2022 Letter INSPECTION SUMMARY
08/01/2022 Letter INSPECTION SUMMARY
08/17/2022 Letter INSPECTION SUMMARY
08/17/2022 Letter INSPECTION SUMMARY
08/25/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter INSPECTION SUMMARY
08/31/2022 Letter INSPECTION SUMMARY
11/22/2022 Letter INSPECTION SUMMARY
11/28/2022 CB-23 Piers
12/12/2022 Letter INSPECTION SUMMARY
12/12/2022 Letter INSPECTION SUMMARY
12/12/2022 Letter INSPECTION SUMMARY
12/12/2022 Plot Plan APPROVED AS BUILT PLOT PLAN
12/14/2022 Letter Field Certificate of Occupancy
12/14/2022 Letter Codes Final Certificate of Occupancy
12/14/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: