Permit Application Status

PRRES20220348


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220348
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT.
01/26/2022
02/15/2022
11/29/2022
Locations
Contacts
ELEVATE DESIGN & BUILD LLC, Address:350 SW LONGVIEW BLVD, Phone:(816) 622-8826  
Elevate Design + Build , Address:350 Longview Blvd.   
R-MECH HEATING COOLING PLUMBING/RHODES HEATING COOLING PLUMBING AND ROOTER, Address:1425 AGNES AVE, Phone:(816) 920-5955  
ELECTRICAL CONNECTIONS, Address:20112 HOPS CREEK DR, Phone:(816) 838-6946  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
GLEN@elevatedesignbuildkc.com  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $360.00 $360.00 Paid 02/15/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 02/15/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 02/15/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 02/15/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 02/15/2022
9110078-Valuation Fee New Single Family $833.97 $833.97 Paid 02/15/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 11/23/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 11/23/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 11/23/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 3/16/2022 3/16/2022 03/16/2022
Sewer Service Inspection - R Passed 3/22/2022 (1:00) 3/22/2022 03/22/2022
Water Service Inspection - R Partial 3/22/2022 (1:00) 3/22/2022 03/22/2022
Water Service Inspection - R Passed 3/24/2022 (9:15) 3/24/2022 03/24/2022
Footing Inspection - Residential Passed 9/1/2022 09/01/2022
Misc
Informational
09/01/2022
Third party inspection
Gas Service Inspection - Residential Failed 9/1/2022 9/1/2022 09/01/2022
Misc
Corrective Action Required
09/01/2022
-pressure gauge not working properly -bond gas line
Electrical Service Inspection Passed 9/1/2022 9/1/2022 09/01/2022
All Rough Inspection - Residential Failed 9/1/2022 9/1/2022 09/01/2022
Misc
Corrective Action Required
09/01/2022
-Address rafters landing on blocks throughout -address rafters to ceiling joist connections throughout -address top plate penetration NE -nail top plate to header at garage portal frames per design -protect NM Within 6’ of attic access -address over bored studs for service entry in garage -seal gaps and penetrations into furr down in pantry (see beam and entry wall) -address top plates lapped less than 24” dining room -nail cspf at rear living room windows to design -address 2x4 layed flat for furr downs -all anchor bolts in basement to be tight -seal gap in fire block in bed 4 S wall -mid way strap 2” dwv in bed 4 closet -seal penetrations in RA joist space above basement linen closet -seal penetrations in bed 3 closet to ceiling space -seal penetrations in RA joist space above bed 3 -gas line pressure gauge not working correctly -bond gas line
All Rough Inspection - Residential Failed 9/15/2022 9/15/2022 09/15/2022
Misc
Corrective Action Required
09/01/2022
-Address rafters landing on blocks throughout provide engineering -address rafters to ceiling joist connections throughout provide engineering -address top plate penetration NE garage wall -protect NM Within 6’ of attic access -address over bored studs for service entry in garage naill off stud shoes -seal gaps and penetrations into furr down in pantry (see beam and entry wall) -all anchor bolts in basement to be tight -seal gap in fire block in bed 4 S wall -mid way strap 2” dwv in bed 4 closet -seal penetrations in RA joist space above basement linen closet -seal penetrations in bed 3 closet to ceiling space -seal penetrations in RA joist space above bed 3 -bond gas line
Gas Service Inspection - Residential Failed 9/15/2022 9/15/2022 09/15/2022
Misc
Corrective Action Required
09/01/2022
-bond gas line Pressure is good
All Rough Inspection - Residential Not Ready 9/22/2022 9/22/2022 09/22/2022
Misc
Corrective Action Required
09/15/2022
-Address rafters landing on blocks throughout provide engineering provide way to view top of blocks -seal gaps in fire block and penetrations into furr down in pantry (see beam and entry wall) MUST USE APPROVED METHOD -mid way strap 2” dwv in bed 4 closet -seal penetrations in RA joist space above basement linen closet -seal penetrations in RA joist space above bed 3
Gas Service Inspection - Residential Passed 9/22/2022 9/22/2022 09/22/2022
Misc
Resolved
09/22/2022
-bond gas line Pressure is good
All Rough Inspection - Residential Passed 9/27/2022 9/27/2022 09/27/2022
Misc
Resolved
09/27/2022
-Address rafters landing on blocks throughout provide engineering provide way to view top of blocks -seal gaps in fire block and penetrations into furr down in pantry (see beam and entry wall) MUST USE APPROVED METHOD -mid way strap 2” dwv in bed 4 closet -seal penetrations in RA joist space above basement linen closet -seal penetrations in RA joist space above bed 3
Piers/Caissons Inspection - Residential Not Ready 10/24/2022 (9:15) 10/24/2022 10/24/2022
Misc
Corrective Action Required
10/24/2022
-piers no to plans -piers full of water and trash
Piers/Caissons Inspection - Residential Failed 10/27/2022 (11:30) 10/27/2022 10/27/2022
Misc
Corrective Action Required
10/24/2022
-piers no to plans -3 18/36" piers
Piers/Caissons Inspection - Residential Not Ready 11/2/2022 (2:00) 11/2/2022 11/02/2022
Misc
Corrective Action Required
10/27/2022
-piers not to plans -3 18/36" piers -piers still not to plans Mitchell Schwarz 11/02/2022 2:20 PM
Driveway Inspection Partial 11/3/2022 11/3/2022 11/03/2022
Misc
Informational
11/03/2022
11-3-22 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour.
Sidewalk Inspection Partial 11/3/2022 11/3/2022 11/03/2022
Misc
Informational
11/03/2022
11-3-22 RH. Sidewalk is formed up and aggregate is placed and compacted. Approved to pour.
Piers/Caissons Inspection - Residential Passed 11/3/2022 11/03/2022
Misc
Corrective Action Required
11/02/2022
-piers not to plans -3 18/36" piers -piers still do not match plans. Mitchell Schwarz 11/02/2022 2:20 PM
Driveway Inspection Passed 11/10/2022 11/10/2022 11/10/2022
Misc
Informational
11/03/2022
11-3-22 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour. 11-10-22 RH. Driveway meets LS and ADA specification.
Sidewalk Inspection Passed 11/10/2022 11/10/2022 11/10/2022
Misc
Informational
11/03/2022
11-3-22 RH. Sidewalk is formed up and aggregate is placed and compacted. Approved to pour. 11-10-22 RH. Sidewalk meets LS and ADA specification.
Occupancy Inspection - Codes Residential Failed 11/23/2022 11/23/2022 11/23/2022
Misc
Corrective Action Required
11/23/2022
-provide as graded plot plan -pay all fees -obtain lawn irrigation permit -outlet at entry not working -stairs in garage greater than 3/8” different in rise -garage door to be self closing and latching -GFCI protection in laundry -kitchen outlets have wiring issues will check when resolved -outlets in master bath to be GFCI protected -GFCI protection for outlets in unfinished spaces -label breaker correctly -lock out for all hardwired appliance breakers at panel when non in plane sight -afci protection as required by code -water heater relief valve piping to comply with code section p2804.6.1 -(2) 1/2” through bolts at each deck post to beam connections -complete deck for inspection back door to remain bordered up until deck is inspected. -anti tamper caps at A/c unit -sod -splash blocks and sump pump discharge to extend 36” from foundation -security lamp at rear of home
Erosion Control Inspection Residential Passed 11/29/2022
Plot Plan Inspection Passed 11/29/2022 11/29/2022
Occupancy Inspection - Codes Residential Full C of O 11/29/2022 11/29/2022 11/29/2022
Misc
Resolved
11/29/2022
-GFCI protection in laundry -kitchen dishwasher GFCI protection
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home