PRRES20220198
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO STOP WORK ORDER generated on 03/10/2022 12:00 AM by username 'Michael Harkins'. STOP WORK ORDER removed on 03/14/2022 12:00 AM by username 'Michael Harkins'.
01/18/2022
01/20/2022
11/03/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
michael@summithomeskc.com  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,350.41 $1,350.41 Paid 01/20/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 01/20/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/20/2022
8331507-Sewer Connection Fee $570.00 $570.00 Paid 01/20/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 01/20/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 01/20/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed - Stop Work 3/10/2022 03/10/2022
Miscellaneous Correction
Corrective Action Required
03/10/2022
NO FOOTING INSPECTION ON RECORD SUBMIT 3RD PARTY INSPECTIONS WITHIN 48 HOURS OF POUR
Footing Inspection - Residential Passed 3/14/2022 03/14/2022
Miscellaneous Correction
Resolved
03/14/2022
NO FOOTING INSPECTION ON RECORD SUBMIT 3RD PARTY INSPECTIONS WITHIN 48 HOURS OF POUR
Misc
Informational
03/14/2022
3RD PARTY FOOTING BY DEREK PEREZ @ EVERSTEAD SIGNED & SEALED BY BRADLEY HUXOL UFER LOCATED UNDER FRONT STOOP
Underslab Plumbing Inspection - Residential Passed 3/15/2022 3/15/2022 03/15/2022
Sewer Service Inspection - R Passed 5/9/2022 (2:00) 5/9/2022 05/09/2022
Water Service Inspection - R Passed 5/10/2022 (11:30) 5/10/2022 05/10/2022
Electrical Service Inspection Passed 6/21/2022 6/21/2022 06/21/2022
Gas Service Inspection - Residential Failed 6/21/2022 6/21/2022 06/21/2022
Misc
Corrective Action Required
06/21/2022
-Nail garage exterior wall sheathing per code -Over notched joist above garage (between chase and steel column) -Repair cut out vapor barrier in garage and great room -Use proper nail plate to protect wiring at front bedroom/office, strap with holes -Provide double top plate support or add stud under H trusses at stair wall; tie down trusses to support stair wall -Fb Jack&Jill bathroom wall from roof -Tie down girder truss K5 -Master bathroom shower trap weir is above the vent connection -Support kitchen island sink drain pipe **OK TO INSULATE
Gas Service Inspection - Residential Passed 06/21/2022
Misc
Resolved
06/21/2022
All Rough Inspection - Residential Failed 6/21/2022 6/21/2022 06/21/2022
Misc
Corrective Action Required
06/21/2022
-Nail garage exterior wall sheathing per code -Over notched joist above garage (between chase and steel column) -Repair cut out vapor barrier in garage and great room -Use proper nail plate to protect wiring at front bedroom/office, strap with holes -Provide double top plate support or add stud under H trusses at stair wall; tie down trusses to support stair wall -Fb Jack&Jill bathroom wall from roof -Tie down girder truss K5 -Master bathroom shower trap weir is above the vent connection -Support kitchen island sink drain pipe **OK TO INSULATE
All Rough Inspection - Residential Failed 6/23/2022 6/23/2022 06/23/2022
Misc
Corrective Action Required
06/21/2022
-Master bathroom shower trap weir is above the vent connection Shawn Hoffman 06/23/2022 9:05 AM [ NOT COMPLETE ] **OK TO INSULATE
All Rough Inspection - Residential Passed 6/27/2022 6/27/2022 06/27/2022
Misc
Resolved
06/27/2022
-Master bathroom shower trap weir is above the vent connection Shawn Hoffman 06/23/2022 9:05 AM [ NOT COMPLETE ] **OK TO INSULATE
Driveway Inspection Partial 06/30/2022
Misc
Informational
06/30/2022
Driveway was framed up with aggregate in and compacted. 6/30/22 ES
Driveway Inspection Passed 7/8/2022 7/8/2022 07/08/2022
Misc
Informational
06/30/2022
Driveway was framed up with aggregate in and compacted. 6/30/22 ES Driveway meets LS spec. 7/8/22 ES
Plot Plan Inspection Failed 9/19/2022 09/19/2022
Miscellaneous Correction
Resolved
10/04/2022
Erosion Control Inspection Residential Passed 10/4/2022 10/04/2022
Plot Plan Inspection Passed 10/4/2022 10/04/2022
Miscellaneous Correction
Resolved
10/04/2022
Occupancy Inspection - Codes Residential Failed 10/4/2022 10/4/2022 10/04/2022
Miscellaneous Correction
Corrective Action Required
10/04/2022
No deck pier inspection on record for covered patio Plot plan shows manhole cover west of driveway raise lid to grade level Provide guardrail or raise grade to less than 30" front porch Garage door shall be self latching Provide attic access cover garage Remove dust cover smoke detector 2nd story Provide door attic access in SW bedroom closet Provide 1 1/2 clearance basement handrail ( 2018 IRC R311.7.8.3 ) Secure newel post basement stairs shall withstand 200 lbs of force Provide 6" clearance wood siding to grade rear Water meter lid at grade level maintain 14" a 18" meter to lid Clean street of mud & debris
Piers/Caissons Inspection - Residential Passed 10/19/2022 10/19/2022
Misc
Informational
10/19/2022
3RD PARTY SIGNED & SEALED BY BRADLEY HUXOL DECK PIERS APPROVED
Occupancy Inspection - Codes Residential Full C of O 11/3/2022 11/3/2022 11/03/2022
Miscellaneous Correction
Resolved
11/03/2022
Documents & Images
Date Uploaded File Type Document Name
01/18/2022 W0 #143 - Permit App
01/18/2022 143 WOODSIDE RIDGE TRUSS LAYOUT
01/18/2022 LOT 143 FINAL
01/19/2022 Approved Plans Approved Drawings
01/19/2022 Approved Plans Approved Truss Package
01/19/2022 Approved Plans Approved Truss Layout
01/19/2022 Plot Plan Approved Plot Plan
01/19/2022 Permit Codes Residential Plan Review
01/20/2022 Permit DS Building Permit
01/20/2022 Receipt Receipt for transaction:2022-000327
03/10/2022 Letter Stop Work Order
03/14/2022 143 Woodside Ridge FTNG
03/14/2022 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
05/09/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
06/30/2022 Letter INSPECTION SUMMARY
07/08/2022 Letter INSPECTION SUMMARY
09/16/2022 Plot Plan Approved As Graded Plot Plan
09/19/2022 Letter INSPECTION SUMMARY
10/04/2022 Letter INSPECTION SUMMARY
10/04/2022 Letter INSPECTION SUMMARY
10/04/2022 Letter INSPECTION SUMMARY
10/19/2022 143 Woodside Ridge Post Pour Deck Piers
10/19/2022 Letter INSPECTION SUMMARY
11/03/2022 Letter Field Certificate of Occupancy
11/03/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home