Permit Application Status

PRRES20220175


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220175
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
01/13/2022
01/24/2022
07/17/2022
06/13/2024
Locations
Contacts
ASPEN HOME BUILDERS LLC, Address:6618 ROYAL ST #B, Phone:(816) 507-0123  
Steve Gilliland, Address:6618 Royal Street  
STEVE@ASPENHOMESKC.COM  
MCDANIEL FURNACE & SHEET METAL, Address:2905 S M 291 FRONTAGE RD, Phone:(816) 373-6370  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
N & E Plumbing LLC, Address:17301 Jennifer St.  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $390.00 $390.00 Paid 01/24/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 01/24/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/24/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 01/24/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 01/24/2022
9110078-Valuation Fee New Single Family $1,178.25 $1,178.25 Paid 01/24/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/16/2022 02/16/2022
Underslab Plumbing Inspection - Residential Passed 4/12/2022 4/12/2022 04/12/2022
Sewer Service Inspection - R Passed 6/7/2022 (1:00) 6/7/2022 06/07/2022
Water Service Inspection - R Partial 6/8/2022 (4:00) 6/8/2022 06/08/2022
Misc
Informational
06/08/2022
foundation to meter pit it okay
Water Service Inspection - R Passed 6/9/2022 (9:00) 6/9/2022 06/09/2022
Misc
Resolved
06/09/2022
foundation to meter pit it okay
Piers/Caissons Inspection - Residential Passed 10/5/2022 10/05/2022
Gas Service Inspection - Residential Passed 11/8/2022 11/8/2022 11/08/2022
Electrical Service Inspection Passed 11/8/2022 11/8/2022 11/08/2022
Erosion Control Inspection Residential Failed 11/8/2022 11/08/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
11/08/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. SEE REAR OF LOT
All Rough Inspection - Residential Failed 11/8/2022 11/8/2022 11/08/2022
Misc
Corrective Action Required
11/08/2022
-plate breaks at garage portal to occur in the middle 24” of the portal leg -address rafters landing on blocks throughout -strap top plate E wall in garage where lapped less than 24” -all anchor bolts to be in the middle 1/3 of sill plate throughout -plans call for 3 2x6 ceilings joists for roof bearing garage E -lib to code and plans in master walk in closet -provide proper slope for dwv above master walk in closet -solid block sheathing E master bath wall left of window near top plate -nail exterior wall corners to code -no roof bearing on box vault above master -plans call for smoke/co at great room/entry -security blocking at rear door -uncover covered patio for inspection -strap and nail exterior cspf at main to plans and design -hanger for triple lvl at beam above great room/dining -vent kitchen hood to exterior -missing hanger for ceiling above walk-in pantry -strap S flex room wall to plans -fire block vertically to horizontally at NW REC room beam -all anchor bolts to be tight -missing top plate , straps, anchor bolts and nailing at basement cspf -3 2x6 for rec room N wall -complete hvac above basement bedrooms hall -fireblock dead space and E wall in basement bath into furr down -fireblock E bed 4 wall into furr down -address holes drilled through floor joist near service panel multiple holes drilled closer than 2” -nail exterior siding to plans (missing multiple nails throughout
All Rough Inspection - Residential Failed 11/21/2022 11/21/2022 11/21/2022
Misc
Corrective Action Required
11/08/2022
-sheathing breaks at garage portal to occur in the middle 24” of the portal leg -address rafters landing on blocks throughout -provide proper slope for dwv above master walk in closet -fire block vertically to horizontally at NW REC room beam -missing top plate nailing , anchor bolts and nailing at basement cspf -fireblock E wall in basement bath into furr down -fireblock E bed 4 wall into furr down -address holes drilled through floor joist near service panel multiple holes drilled closer than 2”
All Rough Inspection - Residential Failed 12/2/2022 12/2/2022 12/02/2022
Misc
Corrective Action Required
11/21/2022
-address holes drilled through floor joist near service panel multiple holes drilled closer than 2” in unfinished basement area okay to insulate
Driveway Inspection Partial 12/7/2022 12/7/2022 12/07/2022
Misc
Informational
12/07/2022
11-7-22 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour.
Driveway Inspection Passed 12/14/2022 12/14/2022 12/14/2022
Misc
Informational
12/07/2022
11-7-22 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour. 12-14-22 RH. Driveway meets LS and ADA specification.
Erosion Control Inspection Residential Failed 2/22/2023 02/22/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. SEE REAR OF LOT
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/22/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed 4/28/2023 04/28/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/28/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
04/28/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 04/28/23
Sidewalk Inspection Partial 6/5/2023 6/5/2023 06/05/2023
Misc
Informational
06/05/2023
6-5-23 BR Frames are up and rock is compacted
Sidewalk Inspection Passed 6/9/2023 6/9/2023 06/06/2023
Misc
Informational
06/05/2023
6-5-23 BR Frames are up and rock is compacted 6-6-23 BR Sidewalk is installed and spec to LS standards
Erosion Control Inspection Residential Failed 7/20/2023 07/20/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/28/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Maintain silt fence and overgrown vegetation
All Rough Inspection - Residential Passed 12/11/2023 12/11/2023 12/11/2023
Misc
Resolved
12/11/2023
-address holes drilled through floor joist near service panel multiple holes drilled closer than 2” in unfinished basement area okay to insulate
Plot Plan Inspection Passed 4/16/2024 04/16/2024
Occupancy Inspection - Codes Residential Failed 4/16/2024 4/16/2024 04/16/2024
Misc
Corrective Action Required
04/16/2024
-level water meter well ring and lid -water meter to be 14”-18” from top of meter to well ring lid -address deck post to beam connections
Occupancy Inspection - Codes Residential Failed 4/29/2024 4/29/2024 04/29/2024
Misc
Corrective Action Required
04/16/2024
-address deck post to beam connections(end posts over notched center posts only have one through bolt)
Occupancy Inspection - Codes Residential Failed 5/14/2024 5/14/2024 05/14/2024
Misc
Corrective Action Required
04/29/2024
-address deck post to beam connections(end posts over notched)
Erosion Control Inspection Residential Passed 06/13/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
06/13/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Maintain silt fence and overgrown vegetation
Occupancy Inspection - Codes Residential Full C of O 6/13/2024 6/13/2024 06/13/2024
Misc
Resolved
06/13/2024
-address deck post to beam connections(end posts over notched)
Documents & Images
Date Uploaded File Type Document Name
01/13/2022 Lot 64 Permit App
01/13/2022 Lot 64 Tax App
01/18/2022 Permit Codes Residential Plan Review
01/19/2022 Approved Plans APPROVED PLANS
01/19/2022 Approved Plans APPROVED PLOT PLAN
01/19/2022 Permit Codes Residential Plan Review
01/24/2022 Permit DS Building Permit
01/24/2022 Receipt Receipt for transaction:2022-000385
02/16/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/09/2022 Letter INSPECTION SUMMARY
10/05/2022 Letter INSPECTION SUMMARY
11/08/2022 Letter INSPECTION SUMMARY
11/08/2022 Letter INSPECTION SUMMARY
11/08/2022 Letter INSPECTION SUMMARY
11/08/2022 Letter INSPECTION SUMMARY
11/21/2022 Letter INSPECTION SUMMARY
12/02/2022 Letter INSPECTION SUMMARY
12/07/2022 Letter INSPECTION SUMMARY
12/14/2022 Letter INSPECTION SUMMARY
02/22/2023 Letter INSPECTION SUMMARY
04/28/2023 Letter INSPECTION SUMMARY
06/05/2023 Letter INSPECTION SUMMARY
06/06/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
12/07/2023 Letter Codes 140 Day Letter
12/11/2023 Letter INSPECTION SUMMARY
04/16/2024 Letter INSPECTION SUMMARY
04/16/2024 Letter INSPECTION SUMMARY
04/29/2024 Letter INSPECTION SUMMARY
05/14/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter Field Certificate of Occupancy
06/13/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home