Permit Application Status

PRRES20220168


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220168
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
01/13/2022
01/24/2022
07/13/2022
03/22/2024
Locations
Contacts
ASPEN HOME BUILDERS LLC, Address:6618 ROYAL ST #B, Phone:(816) 507-0123  
Steve Gilliland, Address:6618 Royal Street  
MCDANIEL FURNACE & SHEET METAL, Address:2905 S M 291 FRONTAGE RD, Phone:(816) 373-6370  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
trevor@aspenhomeskc.com  
N & E Plumbing LLC, Address:17301 Jennifer St.  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,478.39 $1,478.39 Paid 01/24/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 01/24/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/24/2022
8331507-Sewer Connection Fee $570.00 $570.00 Paid 01/24/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 01/24/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 01/24/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 02/22/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 2/15/2022 (9:00) 2/15/2022 02/15/2022
Misc
Corrective Action Required
02/15/2022
-apporoved plans need to be uploaded to permit and on site
Footing Inspection - Residential Passed 2/15/2022 (10:00) 2/15/2022 02/15/2022
Misc
Resolved
02/15/2022
-apporoved plans need to be uploaded to permit and on site
Underslab Plumbing Inspection - Residential Passed 4/22/2022 4/22/2022 04/22/2022
Sewer Service Inspection - R Passed 6/6/2022 (1:00) 6/6/2022 06/06/2022
Water Service Inspection - R Partial 6/6/2022 06/06/2022
Misc
Informational
06/06/2022
pex ran from foundation
Water Service Inspection - R Passed 6/8/2022 (2:30) 6/8/2022 06/08/2022
Misc
Resolved
06/08/2022
pex ran from foundation
Piers/Caissons Inspection - Residential Passed 10/5/2022 10/05/2022
All Rough Inspection - Residential Failed 10/31/2022 10/31/2022 10/31/2022
Misc
Informational
10/31/2022
garage portal frame exterior nailing checked and okay.
Gas Service Inspection - Residential Passed 2/13/2023 2/13/2023 02/13/2023
Electrical Service Inspection Passed 2/13/2023 2/13/2023 02/13/2023
All Rough Inspection - Residential Failed 2/13/2023 2/13/2023 02/13/2023
Misc
Resolved
02/13/2023
garage portal frame exterior nailing checked and okay.
Misc
Corrective Action Required
02/13/2023
-fire block garage E wall to ceiling space -fire hvac chase to furr down in garage -attic accessible above garage -provide ladder for inspection of holes drilled in floor joists above garage if closer than 2 inches to one another provide engineered fix -address hanger on double lvl above kitchen/great room -address steel column in pantry not full bearing under beam -address great room window wall not framed to plans -complete cs-pf nailing at master -fire block bed 4 west wall to ceiling space -provide proper slope for dwv above master/master bath
All Rough Inspection - Residential Not Ready 2/22/2023 2/22/2023 02/22/2023
Misc
Corrective Action Required
02/13/2023
-fire block garage E wall to ceiling space(seal gaps) -fire block hvac chase to furr down in garage (not done) -provide ladder for inspection of holes drilled in floor joists above garage if closer than 2 inches to one another provide engineered fix(multiple holes closer than 2”) -address hanger on double lvl above kitchen/great room(not done) -address steel column in pantry not full bearing under beam(not done) -complete cs-pf nailing at master(can not inspect nailing to header) -provide proper slope for dwv above master/master bath
All Rough Inspection - Residential Passed 4/12/2023 4/12/2023 04/12/2023
Misc
Resolved
04/12/2023
-fire block garage E wall to ceiling space(seal gaps) -fire block hvac chase to furr down in garage (not done) -provide ladder for inspection of holes drilled in floor joists above garage if closer than 2 inches to one another provide engineered fix(multiple holes closer than 2”) -address hanger on double lvl above kitchen/great room(not done) -address steel column in pantry not full bearing under beam(not done) -complete cs-pf nailing at master(can not inspect nailing to header) -provide proper slope for dwv above master/master bath
Driveway Inspection Partial 4/21/2023 4/21/2023 04/21/2023
Misc
Informational
04/21/2023
4-21-23 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour.
Sidewalk Inspection Partial 4/21/2023 4/21/2023 04/21/2023
Misc
Informational
04/21/2023
4-21-23 RH. Sidewalk is formed up and aggregate is placed and compacted. Approved to pour.
Driveway Inspection Partial 4/28/2023 4/28/2023 04/28/2023
Misc
Informational
04/21/2023
4-21-23 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour. 4-28-23 RH. Driveway meets LS and ADA inspection.
Driveway Inspection Passed 4/28/2023 04/28/2023
Misc
Informational
04/28/2023
4-21-23 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour. 4-28-23 RH. Driveway meets LS and ADA inspection.
Sidewalk Inspection Passed 4/28/2023 4/28/2023 04/28/2023
Misc
Informational
04/21/2023
4-21-23 RH. Sidewalk is formed up and aggregate is placed and compacted. Approved to pour. 4-28-23 RH. Sidewalk meets LS and ADA specification.
Erosion Control Inspection Residential Failed 4/28/2023 04/28/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/28/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 04/28/23
Erosion Control Inspection Residential Failed 7/20/2023 07/20/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/28/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Maintain overgrown vegetation
Piers/Caissons Inspection - Residential Passed 9/28/2023 09/28/2023
Plot Plan Inspection Passed 2/20/2024 02/20/2024
Occupancy Inspection - Codes Residential Failed 2/20/2024 2/20/2024 02/20/2024
Misc
Corrective Action Required
02/20/2024
Pay all fees -sod -splash blocks and sump pump discharge to extend 36” from foundation -will check water meter at time of sod -obtain issued lawn irrigation permit -safety glazing required on basement windows less than 18” from floor -deck post to beam connection to be to code see 507.5.1 of 2018 IRC
Occupancy Inspection - Codes Residential Temporary C of O 2/27/2024 2/27/2024 02/27/2024
Misc
Corrective Action Required
02/20/2024
-sod -splash blocks and sump pump discharge to extend 36” from foundation -will check water meter at time of sod -safety glazing required on basement windows less than 18” from floor -deck post to beam connection to be to code see 507.5.1 of 2018 IRC (provide engineer letter for fix or fix to code)
Erosion Control Inspection Residential Passed 03/22/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
03/22/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Maintain overgrown vegetation
Occupancy Inspection - Codes Residential Full C of O 3/22/2024 3/22/2024 03/22/2024
Misc
Resolved
03/22/2024
-sod -splash blocks and sump pump discharge to extend 36” from foundation -will check water meter at time of sod -safety glazing required on basement windows less than 18” from floor -deck post to beam connection to be to code see 507.5.1 of 2018 IRC (provide engineer letter for fix or fix to code)
Documents & Images
Date Uploaded File Type Document Name
01/13/2022 Lot 72 plot plan
01/13/2022 Lot 72 Permit App
01/13/2022 Lot 72 Tax App
01/14/2022 Permit Codes Residential Plan Review
01/19/2022 Plot Plan Approved Plot Plan
01/19/2022 Approved Plans Approved Drawings
01/19/2022 Permit Codes Residential Plan Review
01/24/2022 Permit DS Building Permit
01/24/2022 Receipt Receipt for transaction:2022-000386
02/15/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
10/05/2022 Letter INSPECTION SUMMARY
10/31/2022 Letter INSPECTION SUMMARY
02/13/2023 Letter INSPECTION SUMMARY
02/13/2023 Letter INSPECTION SUMMARY
02/13/2023 Letter INSPECTION SUMMARY
02/22/2023 Letter INSPECTION SUMMARY
04/12/2023 Letter INSPECTION SUMMARY
04/21/2023 Letter INSPECTION SUMMARY
04/21/2023 Letter INSPECTION SUMMARY
04/28/2023 Letter INSPECTION SUMMARY
04/28/2023 Letter INSPECTION SUMMARY
04/28/2023 Letter INSPECTION SUMMARY
04/28/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
09/28/2023 Letter INSPECTION SUMMARY
09/28/2023 Letter INSPECTION SUMMARY
02/15/2024 Letter Codes 140 Day Letter
02/20/2024 Letter INSPECTION SUMMARY
02/20/2024 Letter INSPECTION SUMMARY
02/22/2024 Receipt Receipt for transaction:2024-000998
02/23/2024 Pella tempered glass
02/27/2024 Certificate/License Codes Temporary Certificate of Occupancy
03/22/2024 Letter INSPECTION SUMMARY
03/22/2024 Letter Field Certificate of Occupancy
03/22/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home