Permit Application Status

PRRES20220089


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220089
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK GRINDER PUMP - WAITING FOR SPECIFICATIONS
01/07/2022
01/18/2022
07/09/2022
02/06/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
AJ@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,074.59 $1,074.59 Paid 01/18/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 01/18/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/18/2022
8331504-EFHB Middle Big Creek, Full $435.24 $435.24 Paid 01/18/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 01/18/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 01/18/2022
8331507-Sewer Connection Fee $390.00 $390.00 Paid 01/18/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/14/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 02/06/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/14/2022 2/14/2022 02/14/2022
Misc
Informational
02/14/2022
APPROVED PER BRADLEY HUXOL 2/7/22
Underslab Plumbing Inspection - Residential Passed 3/7/2022 3/7/2022 03/07/2022
Erosion Control Inspection Residential Partial 3/7/2022 3/7/2022 03/07/2022
Misc
Corrective Action Required
03/07/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Sewer Service Inspection - R Passed 4/7/2022 (1:00) 4/7/2022 04/07/2022
Water Service Inspection - R Passed 4/8/2022 (11:15) 4/8/2022 04/08/2022
Erosion Control Inspection Residential Failed 4/8/2022 4/8/2022 04/08/2022
Misc
Resolved
04/08/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/08/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Gas Service Inspection - Residential Failed 7/26/2022 7/26/2022 07/26/2022
Misc
Corrective Action Required
07/26/2022
COMPLETE GAS LINES AND PROVIDE PRESSURE TEST
Electrical Service Inspection Failed 7/26/2022 7/26/2022 07/26/2022
Misc
Corrective Action Required
07/26/2022
-separate neutrals and grounds and remove panel bonding screw at basement sub panel -attach GEC to UFER ground -Ampacity adjustment for SE cables installed in attic space is required. Refer to NEC 334/338, 310.15(B)(7)
Misc
Corrective Action Required
07/27/2022
-separate neutrals and grounds and remove panel bonding screw at basement sub panel -attach GEC to UFER ground -Ampacity adjustment for SE cables installed in attic space is required. Refer to NEC 334/338, 310.15(B)(7).
All Rough Inspection - Residential Failed 7/26/2022 7/26/2022 07/26/2022
Misc
Corrective Action Required
07/26/2022
-deck ledger lag connection per code -(2) 1/2” through bolts at each post/beam connection deck -nail all exterior sheathing per plans -provide 30” vertical clearance at attic access -protect electrical within 6’ of attic entry -seal all top plate penetrations at master bath -support/secure all electrical through attic space per code -protection nail plates all NM within 1 1/4” end of stud - see master bed, great room -support/secure NM at home run foyer per code -12” oc nailing all abutting and intersecting corners -provide bocca protection plate DWV top plate front bath stair wall side -protect NM 6” AFF at kitchen island -all truss hangers per plans -provide (2) 2.5 truss hold down clips at B1 trpl girder master bed mid span location per plans -Have engineer from truss manufacturer address broken B6 truss at kitchen -complete gas lines and provide pressure test -address floor joists bores for pex water lines less than 2” apart- see basement bedroom/closet, basement mech room -3.5” SCH 40 steel column at W8x21 steel beam basement per plans -basement furred down, connect 2x4 laid flat to floor joists above to support ceiling load -separate neutrals and grounds and remove panel bonding screw at basement sub panel -attach GEC to UFER ground -Ampacity adjustment for SE cables installed in attic space is required. Refer to NEC 334/338, 310.15(B)(7).
Electrical Service Inspection Failed 8/2/2022 8/2/2022 08/02/2022
Misc
Corrective Action Required
07/26/2022
-Ampacity adjustment for SE cables installed in attic space is required. Refer to NEC 334/338, 310.15(B)(7)
Gas Service Inspection - Residential Passed 8/2/2022 8/2/2022 08/02/2022
Misc
Resolved
08/02/2022
COMPLETE GAS LINES AND PROVIDE PRESSURE TEST
All Rough Inspection - Residential Failed 8/2/2022 8/2/2022 08/02/2022
Misc
Corrective Action Required
07/26/2022
-(2) 1/2” through bolts at each post/beam connection deck -protect electrical within 6’ of attic entry -seal all top plate penetrations at master bath -support/secure all electrical through attic space per code -protection nail plates all NM within 1 1/4” end of stud - see master bed, great room -support/secure NM at home run foyer per code -provide (2) 2.5 truss hold down clips at B1 trpl girder master bed mid span location per plans -address floor joists bores for pex water lines less than 2” apart- see basement bedroom/closet, basement mech room (no letter for fix uploaded) -Ampacity adjustment for SE cables installed in attic space is required. Refer to NEC 334/338, 310.15(B)(7).
All Rough Inspection - Residential Failed 8/10/2022 8/10/2022 08/10/2022
Misc
Corrective Action Required
08/02/2022
-provide (2) 2.5 truss hold down clips at B1 trpl girder master bed mid span location per plans OK TO INSULATE
Electrical Service Inspection Passed 8/10/2022 8/10/2022 08/10/2022
Misc
Informational
08/10/2022
-Ampacity adjustment for SE cables installed in attic space is required. Refer to NEC 334/338, 310.15(B)(7) 80 Amp breaker to sub panel installed at time of inspection.
All Rough Inspection - Residential Passed 8/17/2022 8/17/2022 08/17/2022
Misc
Resolved
08/17/2022
-provide (2) 2.5 truss hold down clips at B1 trpl girder master bed mid span location per plans OK TO INSULATE
Driveway Inspection Partial 9/15/2022 09/15/2022
Misc
Informational
09/15/2022
9-15-22 RH. Driveway is formed up and aggregate is placed and compacted.
Driveway Inspection Passed 9/22/2022 9/22/2022 09/22/2022
Misc
Informational
09/15/2022
9-15-22 RH. Driveway is formed up and aggregate is placed and compacted. 9-22-22 RH. Driveway meets LS and ADA specification.
Erosion Control Inspection Residential Failed 12/13/2022 12/13/2022 12/13/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
12/13/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM5 ESC INSP DENIED
Corrective Action Required
12/13/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Occupancy Inspection - Codes Residential Not Ready 12/13/2022 12/13/2022 12/13/2022
Misc
Corrective Action Required
12/13/2022
INSPECTION DENIED -EROSION CONTROL REQUIRED ON LOT AND TO BE MAINTAINED UNTIL SOD IS PLACED, RESTORE EROSION CONTROL
Occupancy Inspection - Codes Residential Failed 12/15/2022 12/15/2022 12/15/2022
Misc
Corrective Action Required
12/13/2022
-final grade and sod -splash blocks -provide spark ring or move box at great room tv outlet, no box setback allowed with combustible surface -Tamper resistant outlets required per code IRC E4002.14, NEC 406.12(A) -GFCI protection required at dishwasher outlet -master bath GFCI outlet tripping when energized -complete all outlets at laundry, GFCI protection required at washing machine outlet -AFCI protection all circuits per code IRC E3902.16 NEC 210.12(A) -basement stairs handrail must be between 34”-38” in height above stairs riser nosing -secure exterior light fixtures at garage and seal along top of fixture -no current at deck exterior outlet for GFCI test -complete electrical disconnect install at AC, exposed romex -tamper resistant valve caps required at AC
Occupancy Inspection - Codes Residential Not Ready 1/6/2023 1/6/2023 01/06/2023
Misc
Corrective Action Required
12/15/2022
-final grade and sod -splash blocks -Tamper resistant outlets required per code IRC E4002.14, NEC 406.12(A) -GFCI protection required at dishwasher outlet -master bath GFCI outlet tripping when energized -AFCI protection all circuits per code IRC E3902.16 NEC 210.12(A) -secure exterior light fixtures at garage and seal along top of fixture -secure electrical whip within 12” of disconnect at AC -tamper resistant valve caps required at AC -seal along top of AC disconnect
Erosion Control Inspection Residential Passed 2/2/2023 02/02/2023
DCM5 ESC INSP DENIED
Resolved
02/02/2023
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Plot Plan Inspection Failed 2/2/2023 02/02/2023
Miscellaneous Correction
Corrective Action Required
02/02/2023
- uncover manhole at front of lot.
Occupancy Inspection - Codes Residential Failed 2/2/2023 2/2/2023 02/02/2023
Misc
Corrective Action Required
01/06/2023
-Uncover manhole and schedule plot plan inspection. - Pay fees
Plot Plan Inspection Passed 2/6/2023 02/06/2023
Miscellaneous Correction
Resolved
02/06/2023
Occupancy Inspection - Codes Residential Full C of O 2/6/2023 2/6/2023 02/06/2023
Misc
Resolved
02/06/2023
Documents & Images
Date Uploaded File Type Document Name
01/07/2022 MN #113 - PERMIT APP
01/10/2022 Permit Codes Residential Plan Review
01/12/2022 Plot Plan Approved Plot Plan
01/12/2022 Approved Plans Approved Drawings
01/12/2022 Approved Plans Approved Truss Layout
01/12/2022 Approved Plans Approved Truss Package
01/18/2022 Permit Codes Residential Plan Review
01/18/2022 Permit DS Building Permit
01/18/2022 Receipt Receipt for transaction:2022-000309
02/11/2022 113 Manor at Stoney Creek FTNG
02/14/2022 Letter INSPECTION SUMMARY
03/07/2022 Letter INSPECTION SUMMARY
03/07/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/08/2022 Letter INSPECTION SUMMARY
04/08/2022 Letter INSPECTION SUMMARY
07/26/2022 113 Manor at Stoney Creek Letter
07/26/2022 Letter INSPECTION SUMMARY
07/26/2022 Letter INSPECTION SUMMARY
07/26/2022 Letter INSPECTION SUMMARY
08/01/2022 Letter APPROVED TRUSS LETTER
08/02/2022 Letter INSPECTION SUMMARY
08/09/2022 MN 113 pex hole letter
08/10/2022 Letter INSPECTION SUMMARY
08/10/2022 Letter INSPECTION SUMMARY
08/17/2022 Letter INSPECTION SUMMARY
08/17/2022 Letter INSPECTION SUMMARY
08/17/2022 Letter INSPECTION SUMMARY
09/15/2022 Letter INSPECTION SUMMARY
09/22/2022 Letter INSPECTION SUMMARY
12/13/2022 Letter INSPECTION SUMMARY
12/13/2022 Letter INSPECTION SUMMARY
12/14/2022 Receipt Receipt for transaction:2022-009500
12/15/2022 Letter INSPECTION SUMMARY
01/06/2023 Letter INSPECTION SUMMARY
02/02/2023 Letter INSPECTION SUMMARY
02/02/2023 Letter INSPECTION SUMMARY
02/02/2023 Letter INSPECTION SUMMARY
02/03/2023 LOT 113 ASBUILT
02/03/2023 Plot Plan APPROVED AS GRADED PLOT PLAN
02/06/2023 Receipt Receipt for transaction:2023-000676
02/06/2023 Letter INSPECTION SUMMARY
02/06/2023 Letter Field Certificate of Occupancy
02/06/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home