Summary
PRRES20220076
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE. WALKOUT BASEMENT. FINISHED/UNFINISHED BASEMENT. ROOF TRUSSES. COVERED DECK.
01/07/2022
01/12/2022
09/22/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JARED@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $420.00 $420.00 Paid 01/12/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 01/12/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 01/12/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 01/12/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/12/2022
9110078-Valuation Fee New Single Family $1,052.60 $1,052.60 Paid 01/12/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 09/22/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Piers/Caissons Inspection - Residential Passed 2/15/2022 02/15/2022
Misc
Informational
02/15/2022
3RD PARTY DRILLED PIERS FOR FOOTING BY DEREK PEREZ @ EVERSTEAD SIGNED & SEALED BY BRADLEY HUXOL
Footing Inspection - Residential Passed 2/15/2022 02/15/2022
Misc
Informational
02/15/2022
3RD PARTY FOOTING BY DEREK PEREZ @ EVERSTEAD SIGNED & SEALED BY BRADLEY HUXOL UFER LOCATED NEAR SOUTHWEST ( REAR LEFT )CORNER OF GARAGE FOUNDATION
Underslab Plumbing Inspection - Residential Failed 2/22/2022 2/22/2022 02/22/2022
Miscellaneous Correction
Corrective Action Required
02/22/2022
PROVIDE ADDRESS PROVIDE INTERIOR DRAIN TILE
Sewer Service Inspection - R Passed 2/22/2022 (9:15) 2/22/2022 02/22/2022
Water Service Inspection - R Passed 2/22/2022 (9:15) 2/22/2022 02/22/2022
Erosion Control Inspection Residential Failed 3/3/2022 03/03/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/03/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. PROVIDE ADDRESS PROVIDE SILT FENCE CLEAN STREET MAINTAIN GUTTER BUDDY ( REMOVE SEDIMENT BUILD UP
Underslab Plumbing Inspection - Residential Failed 3/3/2022 3/3/2022 03/03/2022
Miscellaneous Correction
Corrective Action Required
02/22/2022
PROVIDE ADDRESS
Miscellaneous Correction
Corrective Action Required
03/03/2022
NO INSPECTION EROSION CONTROL FAILED NO INSPECTIONS UNTIL EROSION CONTROL COMPLETE NO SILT FENCE
Underslab Plumbing Inspection - Residential Passed 3/8/2022 3/8/2022 03/08/2022
Miscellaneous Correction
Resolved
03/08/2022
Miscellaneous Correction
Resolved
03/08/2022
Gas Service Inspection - Residential Passed 6/8/2022 6/8/2022 06/08/2022
Electrical Service Inspection Passed 6/8/2022 6/8/2022 06/08/2022
All Rough Inspection - Residential Failed 6/8/2022 6/8/2022 06/08/2022
Miscellaneous Correction
Corrective Action Required
06/08/2022
- Tighten anchor bolts at portal frame - Sheeting breaks or portal frame not to code - No nail pattern to header on portal frame PFH - Strap top plate garage north wall, minimum over lap - Protect wiring 6’ from attic access - Fur out for B vent doesn’t have 1” clearance from flammable material in garage - Fire block penetration at top plate garage 3 locations south east corner - Address main entry wall not tied in at top plate - Solid block sheet breaks bedroom 2 - Complete LIB in laundry - Fire block penetration gas line at fire place - Security blocking at sliding door main level - Fire block penetration at top plate and attic space in master shower and above vanity - Snow block roof line at master closet - Fire block top plate of both square columns next to stairs - Foam gaps in vertical fire blocking in basement - Provide joist hangers for double joist basement at stairs - Missing nails joist hangers under deck - Security blocking at basement sliding door 3 stud bays out - Fire block vertical every 10’ basement south wall - Solid block cantilever basement into garage - Fire block soffit ends bedroom 4 at steel Beam - Flashing and trim windows - Nail exterior siding to code
All Rough Inspection - Residential Failed 6/16/2022 6/16/2022 06/16/2022
Miscellaneous Correction
Corrective Action Required
06/08/2022
- Protect wiring 6’ from attic access OK to insulate
All Rough Inspection - Residential Passed 6/21/2022 6/21/2022 06/21/2022
Miscellaneous Correction
Resolved
06/21/2022
- Protect wiring 6’ from attic access OK to insulate
Driveway Inspection Partial 6/30/2022 06/30/2022
Misc
Informational
06/30/2022
6-30-22 AN forms are in place and aggregate is present and compacted
Driveway Inspection Passed 7/7/2022 7/7/2022 07/08/2022
Misc
Informational
06/30/2022
6-30-22 AN forms are in place and aggregate is present and compacted Driveway meets LS and ADA spec. 7/8/22 ES
Sidewalk Inspection Partial 7/29/2022 7/29/2022 07/29/2022
Misc
Informational
07/29/2022
Sidewalk was framed up with aggregate in and compacted. 7/29/22 ES
Sidewalk Inspection Passed 8/5/2022 8/5/2022 08/17/2022
Misc
Informational
07/29/2022
Sidewalk was framed up with aggregate in and compacted. 7/29/22 ES Sidewalk meets LS and ADA spec. 8/17/22 ES
Erosion Control Inspection Residential Failed 8/24/2022 08/24/2022
Misc
Corrective Action Required
03/03/2022
- REMOVE PORTA TOILET FROM TOP OF STORM INLET.
Erosion Control Inspection Residential Passed 9/22/2022 09/22/2022
Misc
Resolved
09/22/2022
Plot Plan Inspection Passed 9/22/2022 09/22/2022
Occupancy Inspection - Codes Residential Full C of O 9/22/2022 9/22/2022 09/22/2022
Documents & Images
Date Uploaded File Type Document Name
01/07/2022 W2 #57 - Permit App
01/11/2022 Approved Plans APPROVED DRAWINGS
01/11/2022 Approved Plans APPROVED TRUSS LAYOUT
01/11/2022 Approved Plans APPROVED TRUSS PACKAGE
01/11/2022 Permit Codes Residential Plan Review
01/12/2022 Permit DS Building Permit
01/12/2022 Receipt Receipt for transaction:2022-000211
01/18/2022 Plot Plan APPROVED PLOT PLAN
02/15/2022 57 Woodside Ridge FTNG
02/15/2022 3RD Party Insp Report 57 Woodside Ridge Drille Piers
02/15/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
03/03/2022 Letter INSPECTION SUMMARY
03/03/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/16/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/30/2022 Letter INSPECTION SUMMARY
07/08/2022 Letter INSPECTION SUMMARY
07/29/2022 Letter INSPECTION SUMMARY
08/17/2022 Letter INSPECTION SUMMARY
08/24/2022 Letter INSPECTION SUMMARY
09/22/2022 Receipt Receipt for transaction:2022-007732
09/22/2022 Letter Codes Final Certificate of Occupancy
09/22/2022 Letter Field Certificate of Occupancy
09/22/2022 Plot Plan APPROVED AS BUILT PLOT PLAN
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home