Permit Application Status

PRRES20220056


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220056
Building Permit - Residential
Certificate of Occupancy
MONTICELLO HOMES INC
NEW SINGLE FAMILY
NEW HOUSE. WALK OUT BASEMENT. FINISHED/UNFINISHED BASEMENT. COVERED DECK. ROOF TRUSSES - DEFERRED. ENGINEERED FLOOR SYSTEM - DEFERRED.
01/05/2022
01/20/2022
05/23/2023
Locations
Contacts
MONTICELLO HOMES INC, Address:PO BOX 7005, Phone:(816) 478-4740  
MONTICELLO HOMES INC, Address:623 NE LONE HILL DR  
Andrea Peterson, Address:PO Box 7005  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
HATHEWAY ELECTRIC LLC, Address:3125 SW PRYOR RD, Phone:(660) 232-2419  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
ANDREAPETERSON@COMCAST.NET  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $510.00 $510.00 Paid 01/20/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 01/20/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 01/20/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 01/20/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/20/2022
9110078-Valuation Fee New Single Family $1,310.96 $1,310.96 Paid 01/20/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 03/04/2022
Informational
03/04/2022
FOOTING APPROVED BY ENGINEER
Erosion Control Inspection Residential Failed 3/4/2022 03/04/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/04/2022
DEFICIENT EROSION CONTROL INSTALLATION ALONG THE STREET. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Passed 3/4/2022 3/4/2022 03/04/2022
Erosion Control Inspection Residential Failed 3/29/2022 03/29/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/04/2022
DEFICIENT EROSION CONTROL INSTALLATION ALONG THE STREET AND ALONG PROPERTY LINE. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Piers/Caissons Inspection - Residential Failed 4/4/2022 (8:00) 4/4/2022 03/29/2022
Misc
Corrective Action Required
03/29/2022
***DEFICIENT EROSION CONTROL INSTALLATION ALONG THE STREET AND ALONG PROPERTY LINE. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED*** -DIG SOUTH PIERS DOWN TO BEARING SOIL -REMOVE ALL LOOSE DIRT FROM PIER HOLES -THE NORTH PIER IS A 30" DIA PIER
Piers/Caissons Inspection - Residential Failed 4/4/2022 04/04/2022
Misc
Corrective Action Required
03/29/2022
-REMOVE ALL LOOSE DIRT AND DEBRIS FROM PIER HOLES
Piers/Caissons Inspection - Residential Passed 4/4/2022 04/04/2022
Misc
Resolved
04/04/2022
-REMOVE ALL LOOSE DIRT AND DEBRIS FROM PIER HOLES
Sewer Service Inspection - R Passed 5/27/2022 (9:30) 5/27/2022 05/27/2022
Water Service Inspection - R Partial 5/27/2022 (9:30) 5/27/2022 05/27/2022
Water Service Inspection - R Passed 6/1/2022 (9:00) 6/1/2022 06/01/2022
Gas Service Inspection - Residential Passed 8/12/2022 8/12/2022 08/12/2022
Electrical Service Inspection Passed 8/12/2022 8/12/2022 08/12/2022
All Rough Inspection - Residential Failed 8/12/2022 8/12/2022 08/12/2022
Misc
Corrective Action Required
08/12/2022
**Repair erosion control along the rear of lot -Provide truss package and I joist plan on site -Make sure to nail together girder trusses per plan; tie down GT to walls -Strap wall top plates lapped less than 24” in front bathroom -Fb b-vent chase from roof; Fb gap at triangular space adjacent to fireplace shelf -Provide wood shim at deck door strike plate per security code -Note: girder truss above rear dining very unusual. Check truss plan -Install truss hanger at girder truss near 3rd car garage -Have engineer address damage to truss gusset plate of garage girder truss -Strap north garage wall top plate to adjacent wall -Anchor sill plate near sump pump pipe -Fb front basement bedroom closet wall from joist -Protect wiring at top of front bedroom half wall -Protect water line at basement bathroom -Gas pipe union located across door to unfinished basement cannot be concealed **OK TO INSULATE
All Rough Inspection - Residential Passed 8/29/2022 8/29/2022 08/29/2022
Misc
Resolved
08/29/2022
-Provide truss package and I joist plan on site
Gas Service Inspection - Residential Passed 8/29/2022 08/29/2022
Informational
08/29/2022
Removed the gas union fiiting and retest of the gas service pipiing-OK
Driveway Inspection Partial 10/25/2022 10/25/2022
Misc
Informational
10/25/2022
10-25-22 AN forms are in place and aggregate is present and compacted
Driveway Inspection Passed 10/26/2022 10/26/2022 11/04/2022
Misc
Informational
10/25/2022
10-25-22 AN forms are in place and aggregate is present and compacted 11-4-22 AN driveway looks good
Erosion Control Inspection Residential Passed 05/04/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/04/2023
DEFICIENT EROSION CONTROL INSTALLATION ALONG THE STREET AND ALONG PROPERTY LINE. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Plot Plan Inspection Passed 5/4/2023 05/04/2023
Occupancy Inspection - Codes Residential Failed 5/16/2023 5/16/2023 05/16/2023
Misc
Corrective Action Required
05/16/2023
-Seal above electrical meter, receptacle cover, etc -Provide handrail at front exterior stair -Provide sewer tracer wire port at grade -Provide a handrail for garage stair with proper profile; garage stair top riser height difference is more than max 3/8” allowed -Provide box extension for all electrical boxes recessed more than 1/4” behind non-combustible wall finish (kitchen and pantry) -Remove all foundation wall metal ties -In unfinished basement space with electrical service, fire block opening at top of wall to protect the rest of I joists -Provide AFCI protection for all outlets required per NEC 210.12. (Breaker 15, 35) -Provide breaker lock for oven and kitchen hood -Install a CO/smoke alarm outside basement bedroom
Occupancy Inspection - Codes Residential Full C of O 5/23/2023 5/23/2023 05/23/2023
Misc
Resolved
05/23/2023
-Provide handrail at front exterior stair -Provide a handrail for garage stair with proper profile; garage stair top riser height difference is more than max 3/8” allowed
Documents & Images
Date Uploaded File Type Document Name
01/05/2022 Residental Permit Application Lot 320
01/05/2022 License_Tax_Application Lot 320
01/05/2022 COMPLETE SET 05-111-49 Lot 320
01/07/2022 Permit Codes Residential Plan Review
01/13/2022 Plot Plan APPROVED PLOT PLAN
01/20/2022 Approved Plans APPROVED DRAWINGS
01/20/2022 Permit Codes Residential Plan Review
01/20/2022 Permit DS Building Permit
01/20/2022 Receipt Receipt for transaction:2022-000353
02/14/2022 2032 NE Bluestone LSMO Park Ridge Lot 320 Foundation Footing Inspection Report 2-14-22
03/04/2022 Letter INSPECTION SUMMARY
03/04/2022 Letter INSPECTION SUMMARY
03/04/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
04/04/2022 Letter INSPECTION SUMMARY
04/04/2022 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
06/01/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter INSPECTION SUMMARY
08/26/2022 Letter APPROVED TRUSS LETTER
08/26/2022 Letter APPROVED TRUSS LETTER
08/26/2022 Approved Plans APPROVED TRUSS PACKAGE
08/29/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter INSPECTION SUMMARY
10/25/2022 Letter INSPECTION SUMMARY
11/04/2022 Letter INSPECTION SUMMARY
05/03/2023 Plot Plan APPROVED AS BUILT PLOT PLAN
05/04/2023 Letter INSPECTION SUMMARY
05/04/2023 Letter INSPECTION SUMMARY
05/16/2023 Letter INSPECTION SUMMARY
05/16/2023 Letter INSPECTION SUMMARY
05/23/2023 Letter Field Certificate of Occupancy
05/23/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home