Permit Application Status

PRRES20216533


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20216533
Building Permit - Residential
Certificate of Occupancy
JCM DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
12/29/2021
12/30/2021
12/07/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
JCM DEVELOPMENT LLC, Address:1314 SW MARKET ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
THAD@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,154.11 $1,154.11 Paid 12/30/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 12/30/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 12/30/2021
8331507-Sewer Connection Fee $450.00 $450.00 Paid 12/30/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 12/30/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 12/30/2021
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 11/28/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/20/2022 1/20/2022 01/20/2022
Misc
Informational
01/20/2022
APPROVED PER BRADLEY HUXOL 1/19/22
Sewer Service Inspection - R Passed 2/9/2022 02/09/2022
Water Service Inspection - R Passed 2/10/2022 (10:00) 2/10/2022 02/10/2022
Erosion Control Inspection Residential Failed 2/10/2022 2/10/2022 02/10/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/10/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Underslab Plumbing Inspection - Residential Passed 2/14/2022 2/14/2022 02/14/2022
Electrical Service Inspection Passed 7/13/2022 7/13/2022 07/13/2022
Gas Service Inspection - Residential Passed 7/13/2022 7/13/2022 07/13/2022
All Rough Inspection - Residential Failed 7/13/2022 7/13/2022 07/13/2022
Misc
Corrective Action Required
07/13/2022
-fur down garage ceiling at HVAC to allow for R19 insulation -fur out garage wall for insulation at HVAC -fireblock rim joist at HVAC to basement -fireblock Plumbing fur out garage wall -seal all top and bottom plate penetrations at garage, garage entry , pantry -provide anchor bolt garage PFH per plans -header off cut joist at HVAC box out garage entry, joist supported by non load bearing wall -seal all penetrations through air returns -pan off air return at joist cavity above furred down at great room windows -provide full height 2x6 studs front entry wall -support all DWV every 48” oc, traps not considered support -(2) 2x10 at 1st floor stair wall per plans -can’t inspect all hangers and H2.5 clips with lid and trim installed at covered patio rear and front, on front patio H2.5 clips need to be nailed to plate at beam -all truss hangers per plans -all truss lateral bracing per plans -address top plate to top plate corner lap connection at front entry wall to front bedroom exterior wall, different wall heights -12” oc nailing all abutting and intersecting corners -fireblock dryer vent at laundry, ope to attic space above ceiling line -protection plate at sump line stair wall -provide joist hanger at joist to header for HVAC basement near furnace -provide 1” clearance from combustibles at b vent basement -(3) 2x10 joist at basement near stairs per plans -attic ventilation at rear of house
All Rough Inspection - Residential Failed 8/9/2022 8/9/2022 08/09/2022
Misc
Corrective Action Required
07/13/2022
-secure electric box at duct ceiling furred down garage -fireblock Plumbing fur out garage wall -seal all top and bottom plate penetrations at garage, garage entry , pantry -seal all low volt penetrations throughout -nail off portal tension straps -seal all penetrations through air returns -pan off air return at joist cavity above furred down at great room windows -(2) 2x10 at 1st floor stair wall per plans, (air return blocked )
All Rough Inspection - Residential Passed 8/17/2022 8/17/2022 08/17/2022
Misc
Resolved
08/17/2022
-fireblock Plumbing fur out garage wall seal gaps -seal all top and bottom plate penetrations at garage, garage entry , pantry -nail off portal tension straps -seal all penetrations through air returns -p
Driveway Inspection Partial 8/25/2022 8/25/2022 08/25/2022
Misc
Informational
08/25/2022
5-25-22 RH. Driveway is formed up and aggregate is placed and compacted.
Driveway Inspection Passed 9/1/2022 9/1/2022 08/29/2022
Misc
Informational
08/25/2022
5-25-22 RH. Driveway is formed up and aggregate is placed and compacted.
Misc
Informational
08/29/2022
On Monday, 8-29-2022. I performed a visual inspection of the driveway and found that it met city standards.
Occupancy Inspection - Codes Residential Not Ready 11/22/2022 11/22/2022 11/22/2022
Misc
Corrective Action Required
11/22/2022
INSPECTION DENIED, POST ADDRESS
Erosion Control Inspection Residential Passed 11/29/2022 11/29/2022 11/29/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
11/29/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Plot Plan Inspection Passed 11/29/2022 11/29/2022
Occupancy Inspection - Codes Residential Failed 11/29/2022 11/29/2022 11/29/2022
Misc
Corrective Action Required
11/22/2022
NO ACCESS, KEYS PROVIDED IN LOCKBOX DO NOT WORK LOCKS ON HOUSE NO INTERIOR INSPECTION, EXTERIOR ITEMS ONLY -GUARDRAIL REQUIRED AT FRONT PORCH, 30" OR MORE FROM GRADE -DOWNSPOUT DISCHARGE MUST EXTEND MIN 36" DISTANCE FROM FOUNDATION
Occupancy Inspection - Codes Residential Failed 11/30/2022 11/30/2022 11/30/2022
Misc
Corrective Action Required
11/29/2022
-GUARDRAIL REQUIRED AT FRONT PORCH, 30" OR MORE FROM GRADE -DOWNSPOUT DISCHARGE MUST EXTEND MIN 36" DISTANCE FROM FOUNDATION -no more than 3/8” variance between riser heights at garage stairs -hot water heater discharge pipe min 2X pipe diameter AFF, maximum 6” AFF
Occupancy Inspection - Codes Residential Full C of O 12/7/2022 12/7/2022 12/07/2022
Misc
Resolved
12/07/2022
Documents & Images
Date Uploaded File Type Document Name
12/29/2021 CB #20 - PERMIT APPLICATION
12/30/2021 Drawing Approved Drawings
12/30/2021 Approved Plans Approved Truss Layout
12/30/2021 Approved Plans Approved Truss Package
12/30/2021 Plot Plan Approved Plot Plan
12/30/2021 Permit Codes Residential Plan Review
12/30/2021 Permit DS Building Permit
12/30/2021 Receipt Receipt for transaction:2021-009565
01/19/2022 20 Cobey Creek Subgrade - Spread Footings
01/20/2022 CB 20 - Footing Inspection
01/20/2022 Letter INSPECTION SUMMARY
02/09/2022 Letter INSPECTION SUMMARY
02/10/2022 Letter INSPECTION SUMMARY
02/10/2022 Letter INSPECTION SUMMARY
02/14/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
07/26/2022 CB 20 - Engineering letter 2x6 spliced jack stud
08/09/2022 Letter INSPECTION SUMMARY
08/17/2022 Letter INSPECTION SUMMARY
08/25/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter INSPECTION SUMMARY
11/22/2022 Letter INSPECTION SUMMARY
11/28/2022 Plot Plan Approved As-Graded Plot Plan
11/28/2022 CB-20 PIERS 2
11/28/2022 Receipt Receipt for transaction:2022-009149
11/29/2022 Letter INSPECTION SUMMARY
11/29/2022 Letter INSPECTION SUMMARY
11/29/2022 Letter INSPECTION SUMMARY
11/30/2022 Letter INSPECTION SUMMARY
12/07/2022 Letter Field Certificate of Occupancy
12/07/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home