Permit Application Status

PRRES20216422


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20216422
Building Permit - Residential
Certificate of Occupancy
JCM DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ROOF TRUSSES - UNCOVERED DECK
12/17/2021
12/28/2021
06/19/2022
10/12/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
JCM DEVELOPMENT LLC, Address:1314 SW MARKET ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $420.00 $420.00 Paid 12/28/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 12/28/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 12/28/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 12/28/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 12/28/2021
9110078-Valuation Fee New Single Family $1,036.19 $1,036.19 Paid 12/28/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/19/2022 1/19/2022 01/19/2022
Misc
Informational
01/19/2022
APPROVED PER DAVID P AINSWORTH 1/18/22
Underslab Plumbing Inspection - Residential Failed 2/10/2022 2/10/2022 02/10/2022
Misc
Corrective Action Required
02/10/2022
-SWAP LAV AND TUB IN BASEMENT BATH GROUP, NOT MORE THAN ONE WET VENTED FIXTURE DRAIN SHALL DISCHARGE UPSTREAM OF THE DRY VENTED FIXTURE DRAIN CONNECTION, P3108.2.2 HORIZONTAL WET VENT
Underslab Plumbing Inspection - Residential Passed 2/15/2022 2/15/2022 02/15/2022
Misc
Resolved
02/15/2022
Sewer Service Inspection - R Passed 3/1/2022 03/01/2022
Water Service Inspection - R Passed 3/8/2022 (9:45) 3/8/2022 03/08/2022
Erosion Control Inspection Residential Failed 3/8/2022 3/8/2022 03/08/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/08/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Failed 4/22/2022 4/22/2022 04/22/2022
Misc
Corrective Action Required
04/22/2022
-seal all top plate penetrations -see garage -provide anchor bolts sill plate, front SE corner of single car garage door -provide 30” vertical clearance at attic access garage sgl car -fireblock HVAC box out chase at great room -address floor joist overbored for DWV above garage entry closet -provide stud shoe exterior wall stud bored for DWV 1st floor 1/2 bath -secure strap all vertical DWV 2” or less at mid point -add structural straps at all top plates bored 50% or more on all exterior walls and interior load bearing walls, strap min 1 1/2” wide, extend 6” passed each side of bore and include (4) 10D nails each side of strap -fireblock plumbing chase at pantry -solid block between joists along garage wall to provide lateral restraint -address 2nd floor floor joists throughout kitchen area that have been bored for pex water lines less than 2” from end of joist and bores for pex less than 2” from other adjacent bores for pex -seal floor penetrations at kitchen island -16” oc joist spacing per plans, see kitchen, entry -add security blocking at latch front entry door -solid block all sheathing breaks front entry wall -seal unused bore at sill plate laundry -provide studs shoes exterior studs bored for DWV bath#1 -repair subfloor at toilet flange bath#1 -address floor joists bored for electrical less than 2” from end of joist near furnace -toenail all floor joists to plate per code -provide joist hangers at joist to dbl rim connection above basement egress window -nail all exterior sheathing per bracing design CS-PF at bed #1, see detail in plans /IRC R602.10.6.4 -Provide jumper from ground bar to neutral bar or land CEE on neutral bar
Gas Service Inspection - Residential Passed 4/22/2022 4/22/2022 04/22/2022
Electrical Service Inspection Failed 4/22/2022 4/22/2022 04/22/2022
Misc
Corrective Action Required
04/22/2022
E3607.5 SYSTEM GROUNDING. An unspliced main bonding jumper shall be used to connect the equipment grounding conductor(s) and the service-disconnect enclosure to the grounded conductor of the system within the enclosure for each service disconnect. -Provide jumper from ground bar to neutral bar or land CEE on neutral bar
Erosion Control Inspection Residential Partial 4/22/2022 4/22/2022 04/22/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/22/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Failed 4/29/2022 4/29/2022 04/29/2022
Misc
Corrective Action Required
04/22/2022
-nail all exterior sheathing per bracing design CS-PF at bed #1, see detail in plans /IRC R602.10.6.4 **OK TO INSULATE/ROCK**
Electrical Service Inspection Passed 4/29/2022 4/29/2022 04/29/2022
Misc
Resolved
04/29/2022
E3607.5 SYSTEM GROUNDING. An unspliced main bonding jumper shall be used to connect the equipment grounding conductor(s) and the service-disconnect enclosure to the grounded conductor of the system within the enclosure for each service disconnect. -Provide jumper from ground bar to neutral bar or land CEE on neutral bar
Erosion Control Inspection Residential Partial 4/29/2022 4/29/2022 04/29/2022
All Rough Inspection - Residential Passed 5/10/2022 5/10/2022 05/10/2022
Misc
Resolved
05/10/2022
Erosion Control Inspection Residential Partial 5/10/2022 5/10/2022 05/10/2022
Driveway Inspection Passed 6/2/2022 6/2/2022 06/21/2022
Misc
Informational
06/02/2022
On 6.2.2022 Thursday I performed a driveway inspection and pass the subgrade to pour concrete.
Misc
Informational
06/21/2022
On Tuesday, 6-21-2022. I performed a visual inspection of the existing driveway and found the finish on the driveway passes city standards.
Piers/Caissons Inspection - Residential Passed 7/11/2022 (11:30) 7/11/2022 07/11/2022
Occupancy Inspection - Codes Residential Failed 7/13/2022 7/13/2022 07/13/2022
Misc
Corrective Action Required
07/13/2022
-maintain erosion control on lot until sod is placed -final grade and sod -provide gravel base water meter pit -submit as graded plot plan for review and approval -gutters and downspouts -splash blocks all downspout and sump pump locations, min 36” discharge from foundation -max 3/8” variance between rises at front stairs -GFCI protection all garage outlets -shear off head of set screw anti siphon device main water line spigot -AFCI protection at master bed closet circuit -cap off all future bath underslab plumbing basement -defective GFCI at exterior near AC -provide landing at deck stairs -rear outlet near deck higher than 5.5’ above grade -(2) 1/2” through bolts each post/beam connection at deck
Occupancy Inspection - Codes Residential Temporary C of O 7/25/2022 7/25/2022 07/25/2022
Misc
Corrective Action Required
07/13/2022
-final grade and sod -provide gravel base water meter pit -submit as graded plot plan for review and approval -splash blocks all downspout and sump pump locations, min 36” discharge from foundation -provide landing at deck stairs -(2) 1/2” through bolts each post/beam connection at deck OK FOR TCO - HOUSE USED AS MODEL
Occupancy Inspection - Codes Residential Failed 7/25/2022 7/25/2022 07/25/2022
Misc
Corrective Action Required
07/25/2022
-complete sidewalk, sidewalk inspection required -final grade and sod -provide gravel base water meter pit -submit as graded plot plan for review and approval -splash blocks all downspout and sump pump locations, min 36” discharge from foundation -provide landing at deck stairs -(2) 1/2” through bolts each post/beam connection at deck OK FOR TCO - HOUSE USED AS MODEL
Sidewalk Inspection Passed 8/2/2022 08/02/2022
Misc
Informational
08/02/2022
On Tuesday, 8-02-2022, I performed and passed sidewalk inspection for placement of concrete
Erosion Control Inspection Residential Passed 8/30/2022 8/30/2022 08/30/2022
Plot Plan Inspection Passed 8/30/2022 08/30/2022
Occupancy Inspection - Codes Residential Failed 9/23/2022 9/23/2022 09/23/2022
Misc
Corrective Action Required
07/25/2022
-splash blocks all downspout and sump pump locations, min 36” discharge from foundation OK FOR TCO - HOUSE USED AS MODEL
Occupancy Inspection - Codes Residential Full C of O 10/12/2022 10/12/2022 10/12/2022
Misc
Resolved
10/12/2022
Documents & Images
Date Uploaded File Type Document Name
12/17/2021 CB #152 - PERMIT APPLICATION
12/17/2021 Approved Plans APPROVED PLANS
12/17/2021 Approved Plans APPROVED TRUSS LAYOUT
12/17/2021 Approved Plans APPROVED TRUSS PACKAGE
12/21/2021 Permit Codes Residential Plan Review
12/22/2021 Permit Codes Residential Plan Review
12/28/2021 Plot Plan APPROVED PLOT PLAN
12/28/2021 Permit DS Building Permit
12/28/2021 Receipt Receipt for transaction:2021-009487
01/19/2022 M L Crose 3550 SE Corbin Dr LSMO Cobey Creek Lot 152 Clayton Permit 2021-6422 Footing Inspection Report 1-18-22
01/19/2022 Letter INSPECTION SUMMARY
02/10/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/28/2022 152 Cobey Creek Letter #2
04/29/2022 Letter INSPECTION SUMMARY
04/29/2022 Letter INSPECTION SUMMARY
04/29/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
06/02/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
07/11/2022 Letter INSPECTION SUMMARY
07/11/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
07/25/2022 Letter Codes Temporary Certificate of Occupancy
07/25/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/29/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
08/30/2022 Letter INSPECTION SUMMARY
08/30/2022 Letter INSPECTION SUMMARY
09/23/2022 Letter INSPECTION SUMMARY
10/12/2022 Letter Field Certificate of Occupancy
10/12/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home